Web Analytics Made Easy - StatCounter

Resistance Box Tenders

Get complete information related to latest Resistance Box Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Resistance Box Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Resistance Box Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

Central Government/Public Sector

CTN :45732215 Due date: 06 Jul, 202606 Jul, 2026 NA
Tender For supply, installation and commissioning of decade resistance box as per specification attached. [ warranty period: 30 months after the date of delivery ][quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitted: max 8 lacs ] ]

Central Government/Public Sector

CTN :45736160 Due date: 09 Jul, 202609 Jul, 2026 NA
Tender For supply of motor protection circuit breaker (mpcb) for water pump with auxiliary contact (1 no + 1nc)and terminal block db, current rating: 1-1.6 amp,thermal release range :1.0 to 1.6 a, voltage rating 690 v, class 10, breaking capacity: 50 ka, 3 pole as per rdso spec no: rdso/pe/spec/0192-2018 (rev.1) or latest. suitable for use in switch board cabinet of lhb type ac coaches. make: abb/schneider/siemens/l&t. [ warranty period: 30 months after the date of delivery ] ]

Central Government/Public Sector

CTN :45728257 Due date: 16 Jul, 202616 Jul, 2026 NA
Tender For supply of 10 amps 2p ac rcbos (residual current breaker with over current protection) conforms to iec61009-1, is 12640-2, en 61009-1, short circuit breaking capacity - 10ka, precise sensitivity: 100ma, module: 2 withcat. no. auf3c201010. [ warranty period: 30 months after the date of delivery ] ]

Central Government/Public Sector

CTN :45604809 Due date: 07 Jul, 202607 Jul, 2026 NA
Tender For corrigendum : supply and end termination of over load current protection system along with full end termination suitable for overload and short circuit protection along with miniature circuit breaker distribution board with eight way mcb capacity 415 with busbar rating 200a v, c type rated sc capacity 10ka confirming tois: 13032:1991 latest with housing powder coating siemens grey-7035 with bimetallic terminal connector suitable for 16 dia aluminium tubular busbar for 32a copper palm copper cu etp cw 0041a and aluminium barrel aluminium al 99.5 cable connector temperature resilience, corrosion resistance size: 16 sqmm confirming to is: 5561-1970 with maximum temperature rise of 90 degree celsius. material shall be confirmed todesignation a6 of is: 617-1959. breaking resistance for barrel 85 n/m sq m and for palm 225 n/m sq m with stretching a5% for barrel must be for palm 16. [ warranty period: 30 months after the date of delivery ] ]

Central Government/Public Sector

CTN :45743942 Due date: 07 Jul, 202607 Jul, 2026 NA
Tender For supply and end termination of over load current protection system along with full end termination suitable for overload and short circuit protection along with miniature circuit breaker distribution board with eight way mcb capacity 415 with busbar rating 200a v, c type rated sc capacity 10ka confirming tois: 13032:1991 latest with housing powder coating siemens grey-7035 with bimetallic terminal connector suitable for 16 dia aluminium tubular busbar for 32a copper palm copper cu etp cw 0041a and aluminium barrel aluminium al 99.5 cable connector temperature resilience, corrosion resistance size: 16 sqmm confirming to is: 5561-1970 with maximum temperature rise of 90 degree celsius. material shall be confirmed todesignation a6 of is: 617-1959. breaking resistance for barrel 85 n/m sq m and for palm 225 n/m sq m with stretching a5% for barrel must be for palm 16. [ warranty period: 30 months after the date of delivery ] ]

Central Government/Public Sector

CTN :45731843 Due date: 23 Jul, 202623 Jul, 2026 NA
Tender For supply of set of miniature circuit breaker single pole, ac 240 /415v, 50 hz, type-c, breaking capacity 10 ka, conforming to is /iec 60898-1:2002 incorporating mounting of body as per rdso drg. no. skel 3700, alt.1 with extended terminal suitable for bg ac emu, motor load application with current rating and quantity as follows : (1) 15/16 amps -2 nos./set, (2) 10 amps - 3 nos./set, (3) 32/35 amps - 4nos./ set. (make: legrand/ siemens/ schneider/indo asian/ havells or their authorised dealers only to quote) (note: dealer should enclose latest authorised dealership certificate from oem along withoffer) [ warranty period: 30 months after the date of delivery ] ]

Central Government And Public Sector

CTN :45731115 Due date: 04 Jul, 202604 Jul, 2026 NA
Tender For supply of miniature circuit breaker (mcb) for a7 415v imr, rated current 4a, rated voltage: 230v ac, pole: 1p, d curve, breaking capacity 10ka. make/brand: l&t/siemens/schneider/bch/c&s or similar. hsn code:85362030 ]

CTN :43830945 Due date: 07 Jul, 202607 Jul, 2026 NA
Tender For corrigendum : tender for supply of brush , speed indicator , toothed belt , knob , carbon brush , commutator , screw lp type resi thermo w/o neck , carbon brush , sealing for cover , carbon brush , direct current contractor , ring oil guyidance , aux.contactor , switch yaxely type , toggle , push hood red , push hood white , torsion spring , push hood yellow (pressure hood) , lamp pilot , fuse link , plate indicating , copper segment (contact piece) , toothed belt pulley , clutch electromagnetic , cam circuit element , switch position , terminal strip , conductor rail connector , handle (toggle) , dc contractor 2 pole , al capacitor 10000uf 63v , resistor , magnetic coupling , main contact complete , solenoid valve , side wall compl.(right) , bearing , emergency hand lever , circuit breaker (2000 amp)

CTN :45728571 Due date: 24 Jul, 202624 Jul, 2026 NA
Tender For supply of miniature circuit breaker (mcb) current rating 16a, voltage rating 230 vac, pole 2, breaking capacity 10ka, curve c, (as per s. no.38, place of installation s1f16 & s1f150), conforming to bill of material (annexure-d) of rdso specification no- rdso/pe/spec/ac/0184-2015 (rev-1) make and model is as schneider (a9n2p16c), siemens (5sl42167rc), abb (s202mt-c16), l&t (bb20160c), eaton(faz-c16/2). [ warranty period: 30 months after the date of delivery ] ]

CTN :45715693 Due date: 15 Jul, 202615 Jul, 2026 19.48 Lacs
Tender For tender for supply of erection and fabrication work - pan/quad bodies ki kamzor shell ko kaatkar hatana. 10/12 mm moti plate se taiyar kar yathasthan lagana. andar aur bahar se double coat welding kar leak/proof water/vacuum trial dena. , quad evam pan par lage vapour/steam line mein lage 600/1000 mm dia ke right/angle type vapour valves ko dismantle kar valve ki leak/proof marammat karna evam testing uparant punah yathasthan fit karna. , pan/quad ke vapour pipe ke gale/kamzor vapour pipe bends ko naye fabricate karke badalna 600 mm se 1100 mm dia. , quad evam pan ke vapour pipes. vapour/exhaust steam lines ko majbooti pradan karne ke liye angle iron athva plate se t/rings banakar support dena. , vapour cell. semi/kestner. pan va quad bodies ki purani gali steam jackets ko hatakar nikalna. 10/12 mm plate se naya banakar lagana tatha leak/proof trial dena. , pan. quad. vapour shell adi ka fin type cyclone fit karna. naya 8/10 mm plate se banakar fit karna tatha welding kar santoshjanak trial dena. , quad/pans par sthapit vibhinn steam ke gale/kamzor/leaky valves ko kaatkar/kholkar hatana tatha valve ki vanchhit marammat uparant nirdeshanusar fit karna. , air cooled/dry seed/vacuum/twin vertical crystallizer ki drive ke kshatigrast/ghise hue worm wheels ki gland housings ke bush badalne ke liye worm wheel evam worm shaft housings ko dismantle kar alag karna. gland housings mein naye gun metal bush lag jane par housings ki fitting uparant uplabdh karaye gaye worm wheel evam worm housings ko poorv ki bhanti fit kar alignment karna. , vacuum crystallizer ke shell ke gale/kamzor bhagon ko kaatkar hatana. nai/purani plate se shell modkar yathasthan fit karna. andar aur bahar se leak/proof welding karna tatha bahar se vanchhit strengthening karna. , air/water cooled/vacuum/twin vertical crystallizer ke kshatigrast danton wale worm evam worm wheel ko dismantle kar hatana evam unke sthan par naye worm evam worm wheel fit karna. reduction gear evam motor fit karke alignment karna evam trial dena. , pans/crystallizers par lage vibhinn gutters mein se kamzor gutters ko kaatkar hatana. purani plate se banakar lagana. , air/water cooled crystallizers ki purani/kamzor/tooti hui shaft ko dismantle karna. nai shaft taiyar kar yathasthan lagana evam samast arms lagakar santoshjanak trial dena. , air/water cooled crystallizers ki shaft ke gale/kamzor bhag ko kaatkar hatana. m.s. plate se shaft taiyar kar naye pipe ki shaft yathasthan fit karna evam samast arms poorv ki bhanti lagakar santoshjanak trial dena. , crystallizers ki drive shaft ke dono taraf dheele hue/ghise gun metal bush bearings ko nikalna. naye bush fit kar trial dena. , air/water cooled crystallizer ki shaft par lagi kamzor arms ko kaatkar hatana aur m.s. plate/pipe se nai arms fabricate karke shaft par lagakar sucharu trial dena. , air/water cooled crystallizer ke leaky/kamzor gate valve ko repair karke leak/proof fitting karna. , spray hetu sthapit mf 35x35 spray pumps ke elliptical suction pipes mein se gale/kamzor section pipes ko dismantle kar hatana. 8/10 mm moti m.s. plate se sample anusar may strainer fabricate kar yathasthan fit kar leak/proof trial dena. , quad/pans ke condenser mein lage multi/jet spray boxes ki vanchhit marammat karna. , spray pond ke main header. branch header evam branch lines ke gale/kamzor bhagon ko kaatkar nirdeshanusar nai evam purani plate se taiyar kar yathasthan fit kar leak/proof trial dena. , common injection header ke kamzor bhag ko kaatkar hatana. naya fabricate kar yathasthan erection kar leak/proof trial dena. , injection. spray pump ki drive motor ke gale/kamzor resistance box taiyar karna. sabhi internals fit karna. connection kar santoshjanak trial dena. , vertical spray pump ke gale/kamzor base frame ko dismantle karna. poorv ke anusar naya bed fabricate kar level karke yathasthan lagana evam pump fit kar alignment kar dena. , pans ke gale/kamzor feed distribution headers ko kaatkar hatana tatha unke sthan par nirdeshanusar m.s. plate
 Loading, Please wait...

Connect us via What's Up