Get complete information related to latest Resuscitator Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Resuscitator Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Resuscitator Tenders.
Tender For corrigendum : supply of advanced life support skill trainer mannequin , airways management trainer mannequin , adult cpr training half torso mannequin with cardiac feedback , adult cpr training full body mannequin with cardiac feedback , infant basic cpr training mannequin full torso with cardiac feedback , anatomical torso trauma mannequin with minimum 5 skins for thoracocentesis , anatomical neck trauma mannequin with minimum 5 skins for cricothyroidotomy , adult phlebotomy iv access trainer arm. , pediatric phlebotomy iv access trainer arm , intraosseous access training adult set , intraosseous access training pediatric set , central iv mannequin with internal jugular and subclavian access , aed trainer , ecg simulator and rhythm generator dart , monitor defibrillator pacer with aed , monitor defibrillator capable of defibrillation synchronized cardio version , airway foreign body trainer mannequin , anatomic full spine model , laryngoscope with adult blades , finger pulser oximeter , scoop stretcher , long spine board with immobilization device , bag mask device resuscitator bag adult , bag mask device resuscitator bag paediatric , broselow pediatric emergency tape 1 hardbind ) /bid number: gem/2026/b/7077517 * /dated: 28-01-2026 & & / bid document1 / 23
Tender For manual resuscitator or self-inflating bag (size child). spec: the product should be autoclavable & eto compatible, silicon made. two size of bag to be considered in 1:1 ratio(50% each), bag volume 400-550 ml & bag volume 200-350 ml. each set must be equipped with 2 sets of round face mask for resuscitation, silicon made size 1 & size 0. each set must be equipped with one reservoir bag, oxygen tubing and a reusable waterproof non-plastic carrying box/bag. bidder must provide brochure of the product they are intending to supply with clearly mentioning the materials and other specs. compliance letter without valid document will not be accepted as bid. [ai(2025-26) , item code no.s-51073, sl. no.71]
Tender For supply of led phototherapy single and double , high end 5 para monitor pediatrics , mr 850 humidifier fisher and kaypal , automatic hand dryer , hhhfnc heated humidified high flow nasal canula with 5 sets of reusable tubing , bubble cpap machine with compressor , neonatal t piece resuscitator
Tender For corrigendum : supply of sch viii (supply of needle & syringes) - sch viii (supply of needle & syringes), disposable needle sterile length 1/2" guage 25, suture needle, half circle triangular nos. 2 to 20 (cutting), insulated needle for use with peripheral nerve stimulator 22g x 2" x 50 mm., insulated needle for use with peripheral nerve stimulator 22g x 35 mm., insulated needle for use with peripheral nerve stimulator 24g x 1"x 25 mm., echogent needles for usg guided peripheral nerve blocks 20g / 21g x 100 mm., echogent needles for usg guided peripheral nerve blocks 22g x 50 mm., epidural needles 16 & 18 guage 7.5cm to 11cm (disposable), epidural needles (long length) 18g (more than 100 mm. length), sterile disposable lancet size 28-32 (plastic lancet needle type), sterile disposable hypodermic plastic syringe 20cc, cn. with leur lock, hypodermic syringes,disposable sterile, sterile pack,with/without leur lock, hub 1ml syringe with marking at 0.1 ml, asepto syringe 100 ml of heavy plastic barrel and rubber bulb with marking., bag arm rubber with cover for b.p. apparatus, adult size velcro.rubber bag size 13 x 23 cms., keratome, size 2.8 mm, type-regular(ophthalmic), angle-45 degrees, bevel type- bevel up (pointed)blade-stainless steel/carbon steel,handle- polycarbonate, use- disposable single use, mvr, gauge 23g type-regular(ophthalmic), blade-stainless steel handle- polycarbonate, use- single disposable use, triple lumen catheter 7.5fr with 14g distal lumen, length-15cm. kit contain 1 teflon-coated j nitinol guidewire particularly kink-resistant with guide-advancer. 1 dilator, 10cm long, 3 injection caps, 3 clamps,1 supplementary fixation wing,1 scalpel, 1 syringe 5 ml, 1 adaptor for pressure transducer, 1 puncture needle 18g, 70mm long with a pre-connected valve to aviod air embolism and blood loss, 18g short iv cannula, double lumen subclavian/ jugular catheter kit (adult) ptfe (teflon) cannula curved od 2.7/d 11.5fr-12fr/chx5.3in. (3.8 mm x 13.5 cm) 6 side holes silicon tube s clamping extension, clamp luer lock "y" connector with protective caps size 12.5, 15 with guide wire introducer needle, dialator , 3fr double lumen cvc catheter with 60mm double-lumen polyurethane central venous catheter inserted by seldinger technique, radio opaque material for catheter, the user should be able to choose from 2 type of introducer, i.e.needle 23g or i.v. cannula 22g, latex free, the central venous catheter set should contain: 1 double-lumen polyurethane 3fr catheter, 1 short i.v. cannula 22g, 1 introducer needle 23g, 1 kink resistant guidewire with soft flexible tip, dilator with cylindrical /pencil point tip, 1 secondary fixation wing, 2 injection caps, 1 scalpel, 1.5 ml syringe, peripherally placed radiopaque central single lumen catheter. guage 14/16 (100%) (needles size/catheter size) length - 55cm - 70cm, peripherally placed radiopaque central single lumen catheter. guage 18/20 (100%) (needles size/catheter size) length 30cm - 45cm, fully radiopaque pur catheter 16g for femoral artery centimeter marking from 5-15cm, winged hub for skin fixation, supple distal tip. kit should contain 1 pur catheter with xro lines,1 puncture needle, 1 j guidewire with wishbone-type guidewire advancer, 1 dilator, radial/femoral arterial pe catheter with antikinking collar & fixation wings,straight guide wire, introducer needle.catherter size g- 18, length 10cm, radial/femoral arterial pe catheter 20g, 8cm puncture needle is fitted with a visualization chamber allowing to confirm that the vessel punctured is an artery (pulsatile movement of the blood). the needle is also fitted with a silicone bloodless system valve to avoid loss of blood during vessel puncture and a funnel hub to facilitate the insertion of the guidewire, peripherally inserted central catheter with guide wire with peelable cannula, made of polyurethane, non-toxic, with radio opaque line throughout the catheter with marking every cm with leur connector at proximal en