Get complete information related to latest Ribbon Computer Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Ribbon Computer Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Ribbon Computer Tenders.
Tender For providing of hiring of agency for iso certification service - iso 50001 – energy management system (ems); surveillance audit, as per rfp; as per rfp
Tender For corrigendum : providing of custom bid for services - certification of energy management system (iso 50001:2018) for ennore-tuticorin-bengaluru pipeline
Tender For purchase of equipments - purchase of equipment, 1. configuration design an 8-channel battery analyzer and its accessories 2. power 425 w3. voltage measuring range: 25 mv to 5 v, discharge minimum voltage: 0v or better, accuracy: 0.05% of fs4. current range: 0.5 ma to 6 a, accuracy: 0.05% of fs or better 5. power per channel output power: 30w, stability; +/- 0.1% of fs or better6. time rise time: 1ms (0~full range)7. frequency 10hz8. charge mode of operation: cc, cv, cccv, cp end conditions: voltage, current, relative time, capacity.9. discharge mode of operation: cc, cv, cp, cr, end conditions: voltage, current, test time, capacity, energy.10. pulse mode charge: cp mode, cc mode, discharge: cc mode, cp mode, min pulse width: 500ms, automated switch: automated switch from charge to discharge for each pulse end condition: voltage, relative time11. dcir support for the calculation of the point of the dcir12. cycle cycles: 1 65500 or better, steps: 250 or better, nested function: max three levels of loops13. protective function software, power-down data protection, user-defined safety (upper and lower) tolerance of current, voltage, and delay time14. channel features independent pairs of closed loops for the constant current source and constant-voltage source15. test reports and curves for analysis different types of curves created by software based on user definition. (voltage-time curve, current-time curve, capacity-voltage curve, loops times charge/discharge capacity curve, loops times charge/ discharge efficiency curve, etc.), data reports created by the software. comparison of the performance of the batteries tested in channels, both visually and statistically16. channels independent control17. ac input ac 220v 10% / 50hz 18. voltage and current testing sample 4 wire connecting 19. noise 85db20. data management mysql database21. communication means tcp/ip protocol22. data output excel, txt23. communication interface ethernet port24. number of channels per cabinet 825. accessories: 1. bi-potentiostat: electrochemical workstation or moduletechniques the system should be capable of running the rde / rrde technique simultaneously cyclic voltammetry (cv) with simulation/fitting programs linear sweep voltammetry (lsv) with stripping bulk electrolysis with coulometry (be) differential pulse voltammetry (dpv) with stripping normal pulse voltammetry (npv) with stripping tafel plot (tafel), potentiodynamic deactivation, pitting corrosion, corrosion rate, linear polarization, corrosion current, etc. multi-current steps (istep) amperometric i-t curve (i-t) lifetime testing open circuit potential time (ocpt) chrono amperometry (ca) chrono coulometry (cc) chronopotentiometry with current ramp (cpcr) potentiometric stripping analysis (psa) auxiliary signal measurement channel ir compensation external potential input galvanostatic charge discharge single/multiple cycle -chrono potentiometry (cp) with potential limits, polarity by potential or time, no. of cycles etc. voltage vs current density curves single or multiple potential steps with charge limits, single or multiple current steps, mixed voltage/current control using macro. i-v measurements, i max, pmax, fill factor, etc.impedance ac impedance (imp) 10 hz to 3mhz impedance time (impt) (mott-schottky) impedance potential (impe) impedance simulator with fitting open circuit potential time (ocpt)hardware specification of bi-potentiostat workstation/ module: potentiostat / galvanostat module, 2- or 3- or 4-electrode configuration maximum potential: 10v, maximum current: 250 ma peak or better and 2 amps with +/-25 volts for higher current measurement. compliance voltage: > 13v or better, potentiostat rise time: 300 ns or better galvanostat applied current range: 3na to +/- 100ma or better and upto 2 amps applied current accuracy: 20 pa or better input bias current: 1 pa or better cv and lsv scan rate: 0.000001 to 10,000 v/s. ca and cc pulse width: 0.0001 to 1000 sec imp frequency: 0.00001 t
Tender For corrigendum : consultancy for energy management system development and implementation as per iso 50001 2018 for parichha thermal power project jhansi up
Tender For re-certification of integrated management system (ims) consisting of iso 9001:2015, iso 14001:2015, iso 45001:2018 and energy management system (enms) iso 50001:2018 of electric loco shed, south east central railway, bilaspur for a period of three (03) years.
Tender For installing and commissioning of do sensors and flow meter transmitter to improve energy efficiency, tertiary treatment system (multimedia filter) for reuse of water with complete automation including cable and other accessories and connection to plc and scada for auto operation, web-based or cloud-enabled asset management platform designed to manage, monitor, and maintain all critical assets within the sewage treatment facility at gabbur stp in hubli-dharwad city corporation
Tender For supply of implants /pacemaker /accessories, on rate contract basis - single chamber, ssi, ssir, ssir (paediatrics), ssi mri compatible, ssir mri compatible, vdd/vddr, dual chamber, ddd, dddr, ddd (mri compatible), dddr (mri compatible), dddr ( with at/af management), biventricular pacemakers(crt devices)-crt-p/crt-d, crt-p, crt-p advanced, crt-d, crt-d advanced, crt-d (mri conditional), crt-d (with only lv pacing option), crt-d (with only lv pacing option; mri conditional), "biventricular pacemaker with atrial , rv, quadripolar lv leads and all accessories (mri compatible)", "biventricular pacemaker with atrial , rv, quadripolar lv leads and all accessories(mri compatible)-advanced", icd , single chamber (icds), single chamber (icds)-advanced, single chamber (mri icds), dual chamber (icdd), dual chamber (mri icdd), icd ( with at/af diagnosis), biventricular pacemaker + icd (combo device), biventricular pacemaker + icd (combo device) with atrial , rv, bipolar lv leads, biventricular pacemaker + icd (combo device) with atrial, rv, quadripolar lv leads (mri compatible ), advanced biventricular pacemaker + icd (combo device) with atrial, rv, quadripolar lv leads (mri compatible), leadless pacemaker, implantable loop recorder, implantable loop recorder <1.5cc, ssir mri compatible advanced, dddr mri compatible - advanced, single chamber (mri icds) with bluetooth feature, single chamber (mri icds) with bluetooth and advanced features, dual chamber (mri icds) with bluetooth feature, dual chamber (mri icds) with bluetooth and advanced features, advanced biventricular pacemaker + icd (combo device) with atrial, rv, quadripolar lv leads (mri compatible) with bluetooth connectivity, advanced biventricular pacemaker + icd (combo device) with atrial, rv, quadripolar lv leads (mri compatible) with bluetooth connectivity and multipoint pacing, single chamber rate responsive pacemaker -1, single chamber rate responsive pacemaker -2, double chamber rate responsive pacemaker - 3, double chamber rate responsive pacemaker - 4, dx icd , sicd - lead less single chamber icd. it is a propritory product for boston scientific with 8 years longevity and 81 jule deliverable energy specially indicated for patients who are diabetic, more prone for infection, young patients etc., " conduction system pacing - pre-shaped catheter for conduction system pacing compatible with routine active fixation pacing lead.• catheter should be able to deliver all active pacing fixation, stylet driven extendable helix leads with diameter of 6fr or below.• multiple options of shape availability for various anatomies.• catheter should have integrated hemostasis valve along with facility of contrast injection port.• atraumatic radiopaque tip to facilitate imaging under fluoroscopy.• catheter should have outer diameter of 9fr or less.• should be supplied with compatible 0 .035” guidewire and slitter.• helix locking tool (hlt) along with the catheter provides alternative to the clip – on tool used for retracting /extending of helix."
Tender For corrigendum : supply of hysteroscopic instruments - supply of hysteroscopic instruments, diagnostic hysteroscope-- feature specification- outer diameter 2.7 mm - working length 250 mm 300 mm- angle of view: 30 - field of view wide-angle ( 80 )- image transmission rod lens system (preferred), or fiberoptic- sheath size 3.5 mm (outer sheath)- distension media normal saline or co (based on system compatibility)- light source connection standard fiber optic light post (compatible with xenon or led sources)- port type luer lock inflow port (optional outflow depending on model)- sterilization autoclavable or low-temperature plasma sterilization- material surgical-grade stainless steel and medical-grade polymers, operative hysteroscope (4 mm)- telescope diameter 4.0 mm- working length 270 300 mm- outer sheath diameter 5.5 mm (depending on continuous flow or single-flow sheath)- working channels 1 or 2 channels, standard 5 fr (1.7 mm) instruments- angle of view 30 (standard)- field of view wide-angle, distortion-free- image system rod lens optical system, hd-compatible- sheath type continuous flow (inflow and outflow channels)- material surgical-grade stainless steel- light transmission fiber optic light post, universal connector- distension media compatibility normal saline (for bipolar energy) or non-electrolyte fluid (for monopolar)- electrosurgical compatibility bipolar or monopolar electrodes (rollerball, loop, hook, etc.)- electrode type supported 5 fr electrodes resectoscope type- instrument compatibility operative scissors, graspers, biopsy forceps (5 fr)- sterilization autoclavable (134 c) or low-temperature plasma sterilization, hysteroscopic resectoscopesheath & telescopeouter diameter: 4.0 mm working channel: 1.5 2.0 mm (for scissors, biopsy forceps, graspers, bipolar electrodes)angle of view: 30 length: ~25 30 cmfibre optic light transmission with high-resolution rod lens systemresectoscope system (if using with loop / rollerball)available as mini-resectoscope (4.0 mm)compatible with bipolar energy sourceworking element: spring-loaded resectoscope with 4 mm telescopeelectrodes: loop, rollerball, knife, needle (bipolar compatible)fluid managementcompatible with saline (0.9%) as distension medium (for bipolar)continuous flow sheath for clear visioninflow/outflow channels for pressure-controlled irrigationother featuresautoclavable stainless steelergonomic design for operative stabilitycompatible with standard hd camera and light source systems, hysteroscopic scissors size: 5 fr (~1.7 mm), 30 36 cmpasses through working channel of 4 mm hysteroscope.types: straight / curved / angledmaterial: stainless steel, autoclavable, hysteroscopic biopsy forcepssize: 5 fr (~1.7 mm), 30 36 cm long.fits into working channel of 4 mm operative hysteroscope.types: biopsy (punch), grasping, scissors.jaws: serrated, single/double action, rotatable.reusable (autoclavable)., hysteroscopic morcellatorsystem componentshandpiece with cutting blade (rotating/reciprocating)inner cutting tube (sharp-edged) inside outer sheathcontinuous suction attached simultaneous cutting + tissue removalcompatible hysteroscope sheathdimensionssheath outer diameter: 6 7 mm (mini systems available with 5 mm)working channel: 3 3.5 mm (for morcellator blade)blade sizes: 2.5 3 mm (straight or side-facing cutting window)length: 26 30 cmoptics0 or 12 telescope, 2.9 4 mm rod lenshigh-definition fibre-optic illuminationenergy / working principlemechanical cutting continuous suction for clear vision and specimen collectionworks with normal saline as distension medium, hysteromat fluid management systemspecificationsmedium used: co (rarely now) or, preferably, fluids (normal saline, glycine, mannitol, sorbitol).pressure range: adjustable, usually 30 150 mmhg.flow rate: 50 500 ml/min (depending on model).display: digital display for set pressure, actual pressure, inflow, outflow, and fluid deficit.safety: audible alarms for excessive pressure or fluid deficit (to prevent ove
Tender For providing of hiring of agency for iso certification service - iso 50001 – energy management system (ems), iso 9001 - quality management system (qms), iso 14001 - environmental management system (ems), iso 45001 - occupational health & safety management system (oh..