Web Analytics Made Easy - StatCounter

Risk Assessment System Tenders

Get complete information related to latest Risk Assessment System Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Risk Assessment System Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Risk Assessment System Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

CTN :42901829 Due date: 09 Dec, 202509 Dec, 2025 NA
Tender For purchase of equipments - purchase of equipment, bench top glass insitu airlift photo bioreactor1. vessel capacity: 3 liter borosilicate glass (working volume: two to three liters maximum), vessel hxd ratio 4:1 (400x100mm)2. head plate & bottom plate moc: ss 316l3. ports in top plate: ph sensor; dissolved oxygen (do) sensor; pressure sensor; air in and draft tube; air out; acid/base; sampling; and addition port.4. mixing method: ring sparger to create airlift circulation inside the reactor for uniform mixing and better aeration.5. holders for sensor /adapter / blind stoppers in head plate: ph sensor holder; media double inlet for acid/base dosing; air sparger - ring type for airlift application without stirring, air out with exhaust filter and open/close valve; pressure sensor holder; sampling pipe; blind stopper for un used port; unique suitable ss puncturing needles for sampling, air in, air out, inoculum, feed addition.6. ports in bottom plate with stand: port for temperature sensor; heating finger u-tube heat exchanger; drain.7. holders for sensor / adapter / blind stoppers in bottom plate: holder for temperature sensor, heating finger, u-tube heat exchanger.8. sensors: temperature, gel filled sterilizable ph sensor, & pressure sensor.9. controls and display: modular independent system of ph, temperature, pressure with touch screen graphical display & control; two set point control of ph with three-point buffer auto calibration; aeration by flow meter 0-5lpm with air pump; sterilization controls up to 121 without steam generator along with pressure safety mechanism by independent pressure sensor and digital display & control; automatic digital pressure safety and over temperature safety cutoff and alarm; upgradable control system for future prospective as cstr reactor & dissolved oxygen (do).10. measurement and control range: ph: 2-14; process temperature: 20 to 60 ; sterilization temperature: up to 121 ; and pressure up to 15 psi.11. fixed speed peristaltic pump: for acid/base dosing with teflon non spring head. (2 nos)12. cooling system: chiller cum circulator. chiller temperature range 4 to 40 , bath capacity 5l to cool down the reactor after sterilization and to work process temperature below ambient condition.13. illumination system: two illumination assembly with variable intensity control (1000-3000 lux) around the reactor with independent control switch for photobioreactor, or other application and easy detachable if not in use. 14. essential accessories : silicon tubing for acid/base addition (10m); air in and sampling (10m); water circulation (5m); air vent filters 0.2 micron sterilizable (6nos); and silicon septum (25nos)15. starter kit: spare silicon-o-rings for head plate, bottom plate (1no each), all other ports (5nos each), alen key.16. warranty: one year17. support (must): unconditional onsite technical support shall be provided as and when needed. the supplier must provide complete installation and hands-on demonstration of the equipment at the user site upon delivery.18. the vendor should have a registered presence in india with an authorized local service provider in tamil nadu.

CTN :42922643 Due date: 10 Dec, 202510 Dec, 2025 NA
Tender For purchase of equipments - purchase of equipment:chromatographic workstation with capillary injector, packed injector, and auto-sampler should be quoted. chromatography workstation instruments should be built with self-diagnostic features and active-time management tools for better productivity, general features of chromatography workstation: column oven can accommodate two columns with maximum temperature range up to 400 c with set point resolution of 0.1 c. it should support 20 ramps & maximum temperature ramp rates of 100 c /min. cool down of oven from 400 c to 50 c in less than 5 min. fully automated with electronic pneumatic control afc / ppc / epc (digital control) for injector gas afc/epc/ppc should provide optimum performance with all types of capillary columns. system should have the capability to install a minimum of three injection and four detector ports. capable of detecting h and o across 0.01% 100% ranges (i.e., both trace in a matrix and bulk near-pure streams) column oven: operational temperature range: ambient +10 to 400 c overheat protection: programmable up to 420 c injector port: split/spitless injector 1 no packed injector 1 no, maximum temperature: 400 c, pressure setting range 0 100 psi with control setpoint of 0.01psi for specified pressure range., carrier gas flow control should have constant flow, constant pressure modes and constant linear velocity. auto injector: automatic sample injector up to 15 vials 2 ml vial with crimp set 100 nos, detector: flame ionisation detector (fid) 1 no, minimum detectable quantity: 3 pgc/s or more liner dynamic range: 1 107, maximum acquisition rate: 4 ms (250hz), thermal conductivity detector, sensitivity: >40000 mv maximum acquisition rate: 4 ms, maximum operating temp: 400 cgas cylinders & fittings, gas sampling: zero air, h2, n2 and helium gas cylinder with 2-stage regulators, each 1 no. four-stage gas purification panel and gas tubing. quote a suitable gas sample injector apparatus for the analysis of co2 gas, gas standards and a suitable packed column quote a 6-port gas sampling valve suitable for both manual (through syringe) and auto injection (online) quote sample line, sample loop, heated lines, filters, safety hydrogen purging, and flow control of gas. calibration gasses: suitable gas standards such as ar, he, h2, o2, co and ch4 should be providedpc and ups: pc i5 (or higher), 8gb ram, 1tb hdd, 22-inch led monitor (or higher), ssd: 512 gb, windows 10 os (or higher), wired keyboard and mouse. laser printer b/w, online ups sine wave capacity of 5 kva with battery power backup of 1 hour should be provided by the supplier general terms and conditions:warranty: 3 years manufacturer s warranty certificate. vendor should be an authorised provider of sophisticated high-precision chromatograph workstation systems for the past 15 years or more with: a proven track record in multiple countries and national institutes standard quality certifications such (iso 9001) 5+ past installations of similar systems in india. compliance statement should be enclosed with the quotation. the installation should be done at free of cost. hands-on training for 1 day for two trainees (faculty and scholars) must be provided on operation, maintenance and troubleshooting to two to two-three persons at the site of installation. if required, hands-on training must also be given to our faculty/scholars at a later stage, without any financial commitment to university. the technical details of the quoted instrument must be available on the official website of the principal supplier. the vendor should provide the list of end-users (recent) with contact details. the vendor must submit the latest reference letters from their previous users. trained service engineers in india (with suitable certificates) for the quoted model must be readily available to resolve the technical problems. a list of recent scientific publications in reputed journals from the user institutions where the quoted mode

CTN :42776680 Due date: 05 Dec, 202505 Dec, 2025 NA
Tender For supply of ball valve api 6d for c2 c3 pipeline project of gail c c-- enquiry document-mr, ball valves (api 6d), gen notes to mr, data sheet for eh ball valves (svs), data sheet for 14 inch ug ball valve -mov, data sheet for 14 inch ag mov, data sheet for 12 inch bw ag ball valve, data sheet for 12 inch mov, flg, ag ball valve, data sheet for manual 14 inch flg ag ball valve, data sheet-bw-manual-ug, data sheet manual-rb-flgd, data sheet-rb-flgd-se, data sheet-cryo-bw, data sheet-cryo-flgd, data sheet-lt service-fl, data sheet-lt service-flgd, data sheet-cryo-flgd, data sheet-utility, data sheet-lt service-rb-bw, data sheet, data sheet, specification for documentation requirement from suppliers, specification for quality management system requirements from bidders, blank format-form-b-b1-l-l1-s-s1, blank format-form-t, blank formats-form f-support foot details for ball valve, inspection and test plan for electro-hydraulic control value actuators, itp for electrical motor operated valve actuators, inspection and test plan for onshore ball valves (2, & above), specification for electrical motor operated valve actuators., standard specification for fire protection enclosure of valve actuator and accessories, standard specification for pipeline ball valves (onshore), technical notes for valves, vendor data requirements, vendor data requirement for ball valves, motor operated valve, motor operated valve, motor operated valve, motor operated valve, motor operated valve, job specification, job specification for esh actuator for sv valves, annexure-i to mr 9010

State Government

CTN :41524390 Due date: 17 Dec, 202517 Dec, 2025 3.70 Crore
Tender For corrigendum : technical specification point wise dbs implant & accessories - dbs rechargeable with directional lead with25yr battery life & image guided programming integrated inside clinician programmer with micc multiple independent current control technology with zero volt technology,bluetooth connectivity with clinician and patient programmers, usfda & ce approved kit contents: rechargeable pulse generator-1 , directional lead kit -2 , extension kit -2 , burr hole locking kit -2 , tunneling tool -1 , patient remote control kit -1, patient charging kit -1 , dbs rechargeable with non directional lead with 25yr battery life & image guided programming integrated inside clinician programmer micc multiple independent current control technology with zero volt technology,bluetooth connectivity with clinician and patient programmers. have 8 contact non-directional lead kit with array span of 15.5mm for maximum coverage, usfda & ce approved kit contents:rechargeable pulse generator -1, non-directional lead kit -2, extension kit -2, burr hole locking kit -2, tunneling tool -1, patient remote control kit -1, patient charging kit -1, dbs non rechargeable with directional lead with image guided programming integrated inside clinician programmer micc multiple independent current control technology &bluetooth connectivity with clinician and patient programmers,usfda & ce approved kit contents: non-rechargeable pulse generator -1 , directional lead kit -2 , extension kit -2, burr hole locking kit -2 , tunneling tool -1 , patient remote control kit -1,), dbs non rechargeable with non-directional lead with image guided programming integrated inside clinician programmermicc multiple independent current control technology withbluetooth connectivity with clinician and patient programmers. should have 8 contact non-directional lead kit with array span of 15.5mm for maximum coverage,usfda & ce approved kit contents: non-rechargeable pulse generator -1, non-directional lead 1), dbs implant kit with non-rechargeable, 3t mri compatible and sensing enabled ipg and directional leads.the implanted pulse generator (dbs neurostimulator- ipg) should have a minimum service life of 5-7 years and there should not be a need to recharge it periodically.ipg should have the capability for group programming and ability to store the programming data in ipg itself and retrieve from ipg.the system should be able to sense local field potentials (lfps) from brain targets and this data should be accessible through the physician programmer. the leads should be able to stimulate in specific directions, in addition to the ability to stimulate circumferentially. markers on leads should facilitate directional programming even if lead rotates. the leads should also be able to sense lfps.burrhole kit should be there for securing lead in place. microelectrodes for intra op stimulation and recording should be there.the extension connecting the lead and ipg should be flexiblethere should be a tunneller to place the extension wire and the tunneller should be metallic and firm to enable smooth tunnelling.the system should have approval for conditional full-body 1.5t & 3t mri compatibility.patient programmer, enabling the patient to see and if needed, modify the stimulation under guidance, should be available. patients should be able to mark dyskinesia, tremor etc. using the programmer., dbs implant kit with rechargeable, 1.5t & 3t mri compatible and sensing enabled ipg and directional leads.the implantable pulse generator (dbs neurostimulator- ipg) should have a service life of 15+ years if regularly recharged by the patient at specified intervals.ipg should have the capability for group programming and ability to store the programming data in ipg itself and retrieve from ipg.the system should be able to sense local field potentials (lfps) from brain targets and this data should be accessible through the physician programmer. the system shou
 Loading, Please wait...

Connect us via What's Up