Get complete information related to latest Road Furniture Work Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Road Furniture Work Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Road Furniture Work Tenders.
Tender For bid to ras corrigendum : supply of rocker fork etc e e - rocker fork for 2650t press as per drawing 01 05 130 , thread coupling as per drawing 01 05 005 r2 item no 1 to 4 , lifting rod as per drawing 01 05 236 , mu 25 valve cone for 2650t press as per drawing 01 05 237 sheet 1 , mu 25 valve seat for 2650t press as per drawing 01 05 237 sheet 2 , h c clamp 12 inch copper insert as per drawing 02 01 008 r5 , lift rod of drive system as per drawing 021 01 172 sheet 4 of 9 , rod end of drive system as per drawing 021 01 172 sheet 3 of 9 , screw fitting of drive system as per drawing 021 01 172 sheet 01 of 9 , safety plate of drive system as per drawing 021 01 172 sheet 7 of 9 , guide of drive system as per drawing 021 01 172 sheet 2 of 9 , bushing and ring item no 1 and 2 of drive system as per drawing 021 01 172 sheet 6 of 9 , bolt of drive system as per drawing 021 01 172 sheet 9 of 9 , ball socket of drive system as per drawing 021 01 172 sheet 5 of 9
Tender For corrigendum : purchase of sports physiotherpy lab equipments - focused shockwave therapy the device should be suitable for musculoskeletal use. should be a focused shockwave based on piezo mechanism. should have multi array type piezo electric hand piece. should have accuracy of the shock wave generation cycle(frequency)0~8 10% should have software-based operating system the unit should have large color touch screen for ease of operation. the unit should have accuracy of the operating frequency 0~7000shock 10% the unit should have maximum energy density 0.702 m j/ (when setting at 23 levels) 15% should have shock wave penetration depth 40 20%. should have maximum focus size. 78 1.78 15.81 20% should have maximum pressure 44.01 0.65 mpa the unit should be supplied with piezo hand piece and elastomer gel padas of 8 different sizes, 5mm, 10mm, 15mm, 20mm, 25mm, 30mm, 35mm, and 44mm. the life span of hand piece should be of up to 10 million shocks. should be supplied with trolley with castor wheels. dimension of the device should be approximated 500mmx700mmx 1000mm should have ce or usfda certified., high laser therapy should be class iv high level laser therapy system should have a real-time operating system technology should have maximum laser should be class iv high level laser therapy system should have a real-time operating system technology should have maximum laser power output of 15 watts should have wavelengths of 810 nm & 980 nm should have an aiming beam of 650nm, should have 2 operating modes: continuous wave or pulsed applicate and piece should have embedded finger switch and light, should have a technology to customize patient treatment based on conditions, body area, body type, skin type, chronicity and absorption characteristics applicator should have a fused silica composition massage ball at the point of contact of applicator and skin. pulse frequency: 2, 10, 20, 100, 200, 500, 1000, 2500, 5000 & 10000hz pulse duration: 50% duty cycle at any given pulse frequency setting, should have a 10 hd display touch screen with password protection to reach the home screen should be supplied with 2nos. of laser protection glasses power: 100-240v, 50-60 hz the unit should be supplied with 5 different types and sizes of treatment heads (large cone, large massage ball, flat window, small massage ball, and small cone. the unit should have inbuilt battery. electrical safety class: class i, type b weight should not exceed 4 kilograms (main unit; without applicators & accessories. must have class iii also., combination therapy machine with vaccum should have 3 independent electrotherapy channels, one ultrasound channel should provide multiple clinical waveforms including interferential (2 and 4 poles and isoplanarvector), tens (asymmetric biphasic &symmetric biphasic), han, russian, vms, surged(rectangular &triangular), hvpc, microcurrent, galvanic (continuous, interrupted and low level),rabert & dia dynamic cpid/cpiso should have independent parameter adjustments for each channel including intensity, frequency, duty cycle, vector scan, channel mode, phase duration, ramp, cycle time and treatment time based on waveform should have maximum output intensity up to 140ma should have constant current and constant voltage modes should have 2 colour coded lead wires for easy picking of selected channels should have suggested electrode placement guidelines ultrasound should offer 1 and 3 mhz frequencies should have the ultrasound bnr of 5:1 or lesser should be supplied with one 5cm applicator head should have pulsed & continuous frequency modes (10%, 20%, 50% & 100%) should have variable duty cycles of 16 hz, 48 hz &1 bb 00 hz should have facility to indicate applicator uncoupling should be able to use electrotherapy and ultrasound independently and also in synchronizedcombination of electrotherapy and ultrasound, where ultrasound head functioning as bothultrasound head and electrode should have minimum
Tender For supply of providing and fixing , providing or suppling gloves , providing or suppling shin guards , providing or suppling mouthguards , providing or suppling impact-absorbing mats , providing all flooring material as per given specification , providing or suppling punching bags , providing or suppling focus mitts and pads , providing or suppling kick shields , providing or suppling rubber training knives , providing or suppling training batons , providing or suppling training guns , providing and fixing wall-mounted mirrors , providing and installating projector and screen , providing or suppling sound system , providing or suppling first aid kit , providing or suppling cones and markers , providing or suppling resistance bands , providing or suppling training manuals , providing or suppling handouts , providing all cleaning supplies material , providing or suppling interval timer , providing or suppling stability balls , providing and installation of water dispenser , providing or suppling training dummies , providing or suppling lockers , providing and installation of sanitary napkin vending machine , providing or suppling karate uniform , providing or suppling judo uniform , providing or suppling track suit , providing or suppling half pant and t shirt , providing or suppling sport shoes pair , providing or suppling martial art kit safety , providing or suppling knee cap , providing or suppling bag , providing or suppling note book and pen , providing or suppling general knowledge books , providing or suppling judo mat , providing or suppling punching bag hanging and stable , providing or suppling hurdles 50x300 , providing or suppling cone 50x50 , providing or suppling victory skipping 150 x 50 , providing or suppling wod armour weight belt , providing or suppling resistance belt , providing or suppling v bouncing medicine ball 1 and 2 and 3 kg , providing or suppling life line fitness hg 002 pull bar 72 kg weight , providing or suppling rubber belt , providing or suppling ketli bell , providing or suppling climbing rope , providing or suppling running parachute , providing or suppling sweat napkin , providing or suppling weight machine , providing or suppling chairs with writing pad , providing and installation of ip 4mp cctv camera with nvr 32 channel four sata project series and 2 tb ssd disk and led tv , cables suitable for cctv system (accessories) (q4) , cat 6 patch cord (q2) , cat 6 cable for indoor use (q2) , cat 6 cable for outdoor (q2) , layer 2 access switch (v2) (q2) , networking / server rack (q2)
Tender For repair of bridge at different chainage and roadfurniturework on bhadudih-satnala boram madhopur road t.length-19.09 km under non plan head 2025-26
Tender For supply and installation of nose cone for memu/dmc 3-phase coaches. to dr awing number: 745-1-0-060 alt a col.1. special condition: 1) installation required as per assembly drawing and annexure-a, dt: 13/09/2023 to be followed. in annexure-a, icf to be read as mcf. 2) supply rates and installation rates to be quoted separately. 3) suitable packing to be done to avoid damage during transit and unloading. 4) firm shall confir m and obtain the exact drawings to be followed from mcf/raebareli before start of m anufacturing. packing instruction: no special packing required. the protruding, threaded portion, gauges and loose items etc. if any are to be protected with suitable covering to prevent it from damage. however transit damage if any shall be at the cost of suppl ier. [safety item ]