Tender For corrigendum : replacement of old split ac by new one and re-structuring of electrical wiring in the inspection house situated at ghaziabad district.
Tender For supply of specified in srl no 19 of appendix a , s and f pvc connection pipe of 15 mm bore all as specified in srl no 20 of appendix a , s and f pvc flexible drain pipe of size 30 all as specified in srl no 21 of appendix a , cutting existing road hard standing with width not exceeding 750 mm and 1m deep all as specified in srl no 22 of appendix a , m and l for pcc type b1 using 20 mm graded stone aggregate all as specified in srl no 23 of appendix a , sitc of xlpe cable sizes 4 core 16 sqmm all as specified in srl no 24 of appendix a , m and l for excavation in trenches for cable laying all as specified in srl no 25 of appendix a , m and l for returning filling including spreading leveling watering in layers not exceeding 25 cm all as specified in srl no 26 of appendix a , m and l for removing excavated material all as specified in srl no 27 of appendix a , m and l for sand cushioning all as specified in srl no 28 of appendix a , m and labour for old size sub class b bricks laid in trenches all as specified in srl no 29 of appendix a , m and l for earthing with galvanized steel earth plate size 60cm 60cm 6mm thick all as specified in srl no 30 of appendix a , sitc of lt panel all as specified in srl no 31 of appendix a , sitc of deep freezer having hard top double door cap not less than 500 ltrs all as specified in srl no 32 of appendix a , m and l for point wiring with copper conductor cable 2 point 5sqmm all as specified in srl no 33 of appendix a , s and f switch socket 6a obliq 16a 5 in 1 flush type with gang box all as specified in srl no 34 of appendix a , sitc of inverter technology hot and cold split ac of cap 1 point 5 tr all as specified in srl no 35 of appendix a , s and f single pole and neutral steel metal enclosure with two pin and earth plug and socket with one single pole mcb of 32 amps , m and l for ac sub main wiring with 4 sqmm 1 core all as specified in srl no 36 of appendix a , s and f heavy duty copper pipe half inch dia all as specified in srl no 37 of appendix a , s and f heavy duty copper pipe 1 obliq 4 inch dia all as specified in srl no 38 of appendix a , s and f pvc drain pipes of suitable size 25 mm , sitc of inverter technology hot and cold split ac of cap 2 tr all as specified in srl no 39 of appendix a , m and l for ac sub main wiring with single core 6 sqmm all as specified in srl no 40 of appendix a , s and f heavy duty copper pipe of size 15mm all as specified in srl no 41 of appendix a , s and f heavy duty copper pipe of size 10mm all as specified in srl no 42 of appendix a , automatic line voltage correctors (step type) for domestic use (stabilizer) conforming to is 8448 (q2)
Tender For supply of supply fixing and fabrication and testing desert cooler in gi body sheet with and including cooler fan motor size sweep 450mm fan blade only 230 volts single phase 50 hz , air grill of suitable size made out of 0 point 5mm pgi sheet including gss arrangement , front and side panel made out of 1 mm thick pgi sheet , water tank height shold not less than 11 inch made , submersible pump electric driven single phase 230 volts 50 hz of suitable discharge , service cord of 3 core copper wire 1 point 5 sqmm with plug top 5 amp , electronic fan dimmer 1000 watts ac 230 v for controlling , complete electric wiring of desert coolers as required to operate fan , make of cooler fan motor khaitan oblique havells oblique crompton , make of pgi sheet tata oblique jindal oblique national
Tender For corrigendum : providing of facility management services - lumpsum based - revenue department; water cooler (old repairing) (qty 6); consumables to be provided by service provider (inclusive in contract cost),facility management services - lumpsum based - revenue department; sticker on water cooler (qty 18); consumables to be provided by service provider (inclusive in contract cost),facility management services - lumpsum based - revenue department; ro installation (qty 18); consumables to be provided by service provider (inclusive in contract cost),facility management services - lumpsum based - revenue department; ro new 15a switch board(including wiring and labour) (qty 18); consumables to be provided by service provider (inclusive in contract cost),facility management services - lumpsum based - revenue department; all ac (amplifier board with plug, wiring and labour) (qty 20); consumables to be provided by service provider (inclusive in contract cost)
Tender For corrigendum : providing of facility management services - lumpsum based - revenue department; gyser (repairing work of thermoset coil,wiring, plug board, heating rod, labour included) (qty 20); consumables to be provided by service provider (inclusive in contract cost),facility management services - lumpsum based - revenue department; gyser testing (qty 14); consumables to be provided by service provider (inclusive in contract cost),facility management services - lumpsum based - revenue department; gyser (repairing transportation ) (qty 14); consumables to be provided by service provider (inclusive in contract cost),facility management services - lumpsum based - revenue department; short circuit of ac repiairng (qty 4); consumables to be provided by service provider (inclusive in contract cost)
Tender For tender for supply of ht cable -m and l for searching fault location of ht ug cable 11000 volts laid in trenches ducts with the help of electronic fault locating machine comprising of surge generator pulse echo fault locator with frequency distance calculator etc incl transportation of machinery excavation in normal soil strata exposing the cable fault removal of deteriorated portion of the cable treating of cable of any size including disconnecting and re fixing cables with lugs as per direction of engineer in charge note a charges of cable fault locator and dg set including transportation charges deemed to be included in the quoted rate b necessary testing of cable after making joint will be deemed to be including in the cost of relevent item , supply jointing and testing indoor type cold shrinkable end termination cable joint including all material and accessories suitable for 3 core x 120 minus 185 sqmm xlpe cable of 11000 volts e grade complete all as specified and directed note cost of cutting of existing end termination joint deemed to be included in unit rate , m and l for cable jointing kit for 11 kv earthed grade cable for straight through cold shrink type complete with joining material and accessory suitable for 120 to 185 sqmm 3 core xlpe armored aluminum conductor cable complete all as specified and directed , supplying and laying in repair xlpe insulated screened pvc bedded galvanized steel strip or wire armoured , electrical power cable heavy duty with aluminum conductor 11000 volts grade cross sectional area 120 sqmm x 3 core complete all as specified and directed , supply and fixing in repair mccb 400 amps 3 pole 415 volt 36 ka including under voltage over voltage relay with adjutable thermal setting 80% minuse 100% all as specified and directed , m and l for complete repairing serviceing of ht 11 kv vaccum circuit breaker vcb after disconnecting of all incoming and outgoing connection checking finding of the defective spare parts removing of all moisture content with suitable grade chemical replacement of rusted nuts bolts and washer replacement of all unserviceable post insulator and repair of all busbar joints and covered with ht insulation tape complete external surface as per existing colour and quality replacemnt of all defective internal ac dc circuit wiring repair servicing of breaker trolly including motorized operating mechanism ct pt power pack and calibration of triping relays system and tripping mechanism for regulating the fault flow over current earth fault differential in sequence from down streem to receiving sub stn for accuracy and effective functioning of vcb complete all as specified and as directed note nuts bolts washer cleaning material insulation tape copper wire for circuit wiring and defective ht 11 kv 2 amp fuse carrier oiling greasing to charging spring replacement of hrc fuse 110 220 volt 5 amps setting of over current earth fault relays complete other minor items for repair of breaker shall be deemed in qouated rate replacement of major unserviceable spares accessories shall be measured and paid separately under relevant items , supply and fixing heater 230 volts ac 60 watt for 11 kv ht vcb panel complete all as specifed and as directed make heatco vileco electrical , supply and fixing in replecement of spring charging gear for 11kv vcb panel suitable for 630 400 amp complete all as specified and directed , supply and fixing vacuum interputer for ht11 kv vcbs 630 400 amps brakding capacity 13point 1 ka suitable for alstom make vcb complete all as specified and as directed , taking down and repairing overhauling of air break gang operated switch with do fuse unit 200 amp 400 amp capacity triple pole mechanically operated mounted on insulators and steel frame installed vertically horizontally replacement of broken worn out components oiling and greasing of mechanical moving parts smoothing and polishing of electric contacts with providing conducting jelly of contacts refixed the sam
Tender For supply of split air conditioner, wall mount type (v3) isi marked to is 1391 (part 2),split air conditioner, wall mount type (v3) isi marked to is 1391 (part 2),household refrigerating appliances as per is 17550,voltage stabilizer for automatic operation s p naturally air cooled indoor wall mounted type input varation bet 150 v tp 285 v capacity 5 kva as directed,water cooler fully stainless steel, electric driven single phase approx storage and nominal cooling capacity 40 80 ltrs as directed,modular plug and socket 25 amp, 3 pole having 6 modules having motor starter modular type 25 a mcb mini 3 ka socket 25 a suitable for ac supply as directed,install of hi wall split units indoor-outdoor complete with cordless remote control unit minimum 5 star ratio and ber 3 point 2 of capacity 1 point 5 tr as directed,install of hi wall split units indoor outdoor complete with cordless remote control unit minimum 5 star ratio and ber 3 point 2 of capacity 2 tr as directed,m and l point wiring complete with 4 sq mm frls multi stand