Web Analytics Made Easy - StatCounter

Rotary Calciner Tenders

Get complete information related to latest Rotary Calciner Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Rotary Calciner Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Rotary Calciner Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

CTN :41170333 Due date: 30 Jul, 202530 Jul, 2025 2.00 Lacs
Tender For corrigendum : name of work: protecting of a, b and c type pannel in installed electrical system at 33/11 kv sub-station ram ki paidi, nirmochanghat, saket, makkhapur under electricity distribution division-ayodhya dham, ayodhya

State Government

CTN :41170195 Due date: 04 Aug, 202504 Aug, 2025 4.07 Lacs
Tender For corrigendum : maintenance and testing of n2fire protection system at various sub stations under electricity transmission circle i moradabad

Central Government/Public Sector

CTN :40950957 Due date: 30 Jul, 202530 Jul, 2025 50.00 Lacs
Tender For corrigendum : repair/maint of ceiling/wall/exhaust fan, geyser and petty repair to electirc system at vsb and attending of internal /external electricity complaint in tech area, vayusenabad, mes colony and vsv under ge (af) tughlakabad

State Government

CTN :40985775 Due date: 11 Aug, 202511 Aug, 2025 1.50 Crore
Tender For corrigendum : purchase of gym for strength and conditioning equipments - endurance sectiontreadmill1. machine must be designed for running with heavy duty 4 hp motor.2. should have low start up speed: 0.5 kmph or lesser.3. should have incline increments of 1% or lesser.4. low step height: 7 or lower.5. speed range: 0-20 kmh or more.6. incline: 0-15% or more.7. max user weight: 180 kgs or more.8. belt size : 61 x 22 or more9. should have at least 10 preprogrammed protocols with option for heart rate range control10. led console with feedback for time distance, calories burnt, heartrate, incline, track and more product should have en-957 or astm certification for stationary fitness equipment, curved non- motorized treadmill (self- powered)1. curved non-motorized treadmill should be capable of training the body s all energy systems as a comprehensive system, capable of offering sprinting for aerobic power development2. curved non- motorized treadmill (self powered) should be capable of offering the sports persons to experience a full speed resistance spectrum.3. variable resistance: the curved non- motorized treadmill (self powered) system should have requisite advanced drive technology enabling users to select different levels of reactive resistance, from zero to max. by simply shifting the drive control system, rehab athletes can quickly switch from resistance-free running to an all-out sled push.4. increased metabolic rate: walking with resistance on said curved non-motorized treadmill (self powered) training system should be capable of enhancing energy expenditure significantly compared to walking at the same speed on a traditional treadmill or a non- motorized treadmill without resistance.5. maximum muscle activation: ergonomic design of the curved non-motorized treadmill (self powered) training system should lead to significantly higher activation of the posterior kinetic chain muscles, particularly the glutes and hamstrings, compared to traditional treadmills.6. curved non-motorized treadmill (self powered)- training system should be capable of being operated and controlled exclusively by the force applied / generated by rehab athletes. in order to speed up, provision should be there, where rehab athlete can move to the front of the surface and to slow down, rehab athlete can move to the back of the said treadmill. provision must be there where the training system can be accelerated quickly from a cold start and matches upto the same pace as the rehab athletes intends to attain. the said system should offer an ideal solution for an eco-sustainable facility, by reducing electricity costs and carbon footprint.7. training system should have requisite technology, ergonomic design and advanced engineering solution so that rehab athletes can work hard in a completely safe training environment.the ergonomic design combined with the high- quality components and materials should be of solid, compact product with a versatile nature that endures well to suit high intensity prolong training sessions to ensure maximum durability and reliability.8. provision for proper posture control:the ergonomic design of training system promotes the correct alignment of the ankles, knees, hips and back, so that user can maintain natural posture at all- times and avoid joint and knee stress, regardless of their height and weight. system should offer the provision of simulating the experience of walking/running uphill while preserving the correct biomechanics.9. accessory kit: the training system must be provided with accessory kit which allows for a variety of pulling and pushing exercises through handles or a waist belt.10. technical specifications:a) dimensions range (lxwxh)*:190-200cmx86- 95cmx150-160cmb) console type: a minimum of 6-7 lcd display with back lightc) power supply: lps 5v wall supplyd) power requirement: 200 - 240 v (should comply with standard indian electrical system)e) resistance control: should have magnetic resistance with a min

State Government

CTN :40985784 Due date: 11 Aug, 202511 Aug, 2025 2.50 Crore
Tender For corrigendum : purchase of recovery and rejuvenation lab. - infrared sauna tower irradiance: 55-110 mw/cm2, providing therapeutic benefits rated power: 100-240v ac, 2 amp, 50-60hz, suitable for standard electrical outlets wattage: 350w, combining red light and near-infrared therapy wavelength: 650nm (red light) and 850nm (near-infrared), promoting healing and relaxation led arrays: 70 red light leds (650nm) and 70 near-infrared leds (850nm), ensuring optimal coverage variable optics: 7 60-degree optics for maximum impact and quicker results. emf emissions: no detectable emf emissions at 10-15cm, prioritizing user safety. infrared sauna units with below mentioned features to be preferred- heaters: full spectrum heaters (400w each) or carbon fiber heaters (up to 2160w total power) temperature control: digital temperature and time control for customizable sessions materials: canadian hemlock wood or western red cedar, known for durability and hypoallergenic properties additional features: bluetooth connectivity, chromotherapy lights, and built-in stereo speakers for an enhanced experience. energy efficiency: reduced electricity consumption for cost-effective use temperature range: operating temperatures between 115 f and 140 f for comfortable sessions safety features: person-specific designs and low emf emissions for safe use, cryotherapy chamberwhole body cryo therapy chamber that runs completely on electricity without need of liquidnitrogen low temperatures within the range: -130 to -140 degree celsius. multiple treatment options electric mechanical lift system ensures user s head is outside the chamber to prevent exposure to cryogenic temperatures. real-time skin temperature monitoring using ir tech sensors ensuring safe and controlledcooling. smart software that manages the treatment processes throughout each session. simple quick plug-and-play set up without requiring specialized ventilation. large uhd touchscreen for easy operation and control. at least 3 media monitors for displaying media content. hifi speakers for audio entertainment and ambient audio. work on normal indian 220v at 16a or less, whole-body pneumatic lymphatic drainage machine:key features- multi-chamber design: multiple chambers that inflate and deflate in sequence to mimic manual lymphatic drainage- adjustable pressure: adjustable pressure settings to accommodate different patient needs and comfort levels- programmable treatment: programmable treatment protocols for customized therapy sessions- user-friendly interface: intuitive interface for easy operation and programming- input voltage: ac110v/220v- power consumption: less than 400w- screen: 8-inch wide color touch screen- air pressure: 20-360 mmhg (max pressure 37.5kpa)- cooling device output temperature: 5 to -16 c- output vacuum pressure: 0-110kpa- default time: 0-60 minutes- fuse size: f3al250v- ambient temperature: 5 c to 42 c- number of air bags: 24 bags or 16 pairs atleast - treatment modes: 4 modes atleast - intensity levels: 3 levels- package size: 62x42x31cm approx - gross weight: 15 kg approxsafety features- automatic pressure adjustment: automatic pressure adjustment to prevent excessive pressure and ensure patient comfort- emergency stop: emergency stop feature to quickly deflate chambers in case of discomfort or distress- patient monitoring: optional patient monitoring capabilities to track vital signs and treatment responseadditional features- multiple treatment modes: multiple treatment modes for different conditions, such as lymphedema, edema, and post-surgical swelling- data logging: optional data logging capabilities to track treatment parameters and patient progress- portability: optional portable design for increased flexibility and convenience.certifications: ce or fda clearance, percussion massager (gun massager)key features- percussive action: a percussive action that provides rapid and repetitive strokes to muscles and tissues- adjustable speed: adjustable speed settings to cust

CTN :41062986 Due date: 12 Aug, 202512 Aug, 2025 NA
Tender For corrigendum : extension of fire hydrant system at electricity store center tajganj agra

CTN :41163661 Due date: 12 Aug, 202512 Aug, 2025 NA
Tender For upgradation of electricity sub station at urangpat vill kangpokpi distt manipur d d - 63 kva transformer , transformer equipment , high tension ht sider components , low tension lt side components , high tension wire , electrical insulator , earthing system , 20 by 20 fencing , cement , sand , 20mm aggregates , installation charges

Central Government/Public Sector

CTN :41104631 Due date: 05 Aug, 202505 Aug, 2025 NA
Tender For proposals / offers in two bid system from owners/builders/developers having clear and marketable titles over land and built-up property at ground floor having carpet area of 1800 to 2200 sq.ft (including atm & sdv) approximately with sufficient parking and power connections as per load suggested by electricity board for opening the new branch of bank of baroda at bhind road, from gole ka mandir square to dd nagar gate no. 01, dd nagar, gwalior (m.p) on lease basis

Central Government/Public Sector

CTN :41105354 Due date: 06 Aug, 202506 Aug, 2025 NA
Tender For proposals / offers in two bid system from owners/builders/developers having clear and marketable titles over land and built-up property at ground floor having carpet area of 1800 to 2200 sq.ft (including atm & sdv) approximately with sufficient parking and power connections as per load suggested by electricity board for opening the new branch of bank of baroda at bahodapur tiraha or nearby areas up to 2.00 k.m, on main road, anand nagar, gwalior (m.p) on lease basis

Central Government/Public Sector

CTN :41105355 Due date: 07 Aug, 202507 Aug, 2025 NA
Tender For proposals / offers in two bid system from owners/builders/developers having clear and marketable titles over land and built-up property at ground floor having carpet area of 1100 to 1500 sq.ft (including atm & sdv) approximately with sufficient parking and power connections as per load suggested by electricity board for opening the new branch of bank of baroda at badarwas on main road, shivpuri (m.p) on lease basis
 Loading, Please wait...

Connect us via What's Up