Web Analytics Made Easy - StatCounter

Rotary Switch Panel Tenders

Get complete information related to latest Rotary Switch Panel Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Rotary Switch Panel Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Rotary Switch Panel Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

Central Government / Public Sector

CTN :40420472 Due date: 03 Jun, 202503 Jun, 2025 NA
Tender For supply of voltmeter selector rotary switch with marking l1 - l2, l2 - l3, l3 - l1. rated voltage 1000v ac to l&t sa lzer cat no.61312 sab13tdyr, siemens cat.no.3ld40014dc300rc0 and schneider cat.no.k10d024mch as per bom o f rdso specification no. rdso/pe/spec/ac/0184-2015 (rev 1). acceptable makes: l&t salzer, siemens and schneider o nly acceptable as per above spec. warranty: 30 months from the date of delivery. [ warranty period: 30 months after the date of delivery ]

Central Government/Public Sector

CTN :40296252 Due date: 27 May, 202527 May, 2025 NA
Tender For corrigendum : supply of control switches for fgd kothagudem and fgd bhadradri tps - tnc switch (4p , 3w) 25a , 220v dc , lockable , dc on off switch 220v dc , 25a , dc on off switch 220v dc , 32a , selector switch 4p , 2w , 16a , 220v dc lock(swgr/remote) , selector switch 4p 3w 16a , 220v dc lock(swgr/remote) , ammeter selector switch with off 6a , voltmeter selector switch with off 6a , selector switch 16a 2p 3w dc lockable , selector switch 2p 2w 6a , 110v ac lockable , selector switch 32a/240v ac sorce 1&2 , selector switch 16a 2p 2w dc lockable , on/off ac switch 10a 1p 2w , synch selector switch 2p , 3w 220v dc 25a lockable , synch/head selector switch 4p , 2w , 220v dc 16a lockable

CTN :40329670 Due date: 02 Jun, 202502 Jun, 2025 NA
Tender For supply, fitment and rewiring of baking oven and its lt defective panel at els/bk sc. (1) selec tc203ax digital temperature controller motion controller (black, for ps33 digit single display temperature controller (tc: j, k, t, r, s/ rtd: pt100) sensor input, on-off/auto-tune pid control, single set point, 10a relay/12v ssr control output, 72 mm x 72 mm size, panel mount, 90 to 270v ac/dc supply volt age, qty- 01nos. (2) immersion coil 2000 watt, qty-4 nos (3) mcb 63-amp 3-pole c curve make- l&t and havells, siemens, anchor, qty-3 nos, (4) hrc fuse, 63a, 415v make-l&t, siemens and havells, anchor, qt y-8 nos. (5) hrc fuse, 32a, 415v make- l&t, siemens and havells, anchor, qty-5 nos. (6) dmc kit kat fus e 63 amp 415 volt make- l&t, siemens and havells, anchor, qty-5 nos (7) dmc kit kat fuse 23 amp 415 v olt make-l&t, siemens and havells, anchor, qty-5 nos. (8) l&t, siemens and havells, anchor, power cont actor 70 amp mnx 70,qty-1 nos. (9) minilec vsp3/415 vac phase failure relay ,qty-1 nos. (10) siem ens and havells, anchor, l&t mnx-a1 add-on bl.2no+2nc 4 poles contactor, qty-1 nos. (11) control tra nsformer input-415v output-240v 500kva , make-l&t /siemens/havells,anchor, qty-01nos. (12) copper wire 1.5mm make make- l&t /siemens/havells/anchor, qty-60 mtr. (13) siemens/havells/anchor, salzer (l&t) 10 a voltmeter selector switch (vss) (voltage between phase with off) (yellow) qty-1 nos. (14)cop per wire 2mm make make- l&t /siemens/havells/anchor, qty-80 mtr. (15)push button (green and red) wi th 2no 2nc three phase qty-4 nos. (16) panel indicator (color- red, yellow, blue) qty-4 nos. (17) siemens /havells/anchor, salzer (l&t) 10 a ammeter selector switch (line currents with off) (yellow) qty-1 nos. (18) siemens/havells/anchor, salzer (l&t) 10 a 3 pole 2 way auto-manual 10 a cam operated rotary swi tch (yellow) qty-1 nos. (19)thermocouple temperature control 0-400 c sensor qty-1 nos. (20) analog am pere meter ac (0-200 a) make-ae , digital timer for panel make-l&t, siemens and havells, anchor, qty-1 n os. (21) digital timer for panel make-l&t, siemens and havells, anchor, qty-1 nos. (22) analog volt meter ac (0-500 v). make- ae,l&t, siemens and havells, anchor, qty-1nos. [ warranty period: 30 months after the date of delivery ]

State Government

CTN :40071789 Due date: 02 Jun, 202502 Jun, 2025 NA
Tender For corrigendum : providing and installation of electrical accessories and allieds works at shaspur pwss, block-rampurhat-ii under bolpur mechanical division - supply, delivery at site and storage of wall mounted made of sheet steel fabricated 2 mm for load bearing & 1.6mm for non load bearing, indoor type, dust & vermin proof, lp-54 degree of protection, powder coated painted with rubber gaskets cover, front lockable hinged door with all switchgear and other items duly wired up and tested as per specification: incomer: (a) 100 amps, tpn mccb with adjustable ol, 36 ka, e/f, auto phase corrector & necessary accessories with suitable spd (i.e., ammeter, voltmeter, cts & switches), outgoing:- (b) 7.5 hp to 12.5 hp, tp star-delta starter with other accessories - 1 nos., (suitable size capacitor bank to improve pf from o.85 to 0.98) (c) yard lighting feeder with necessary accessories & time switch(digital) - 1 no. (d) 3phase actuator valve starter with other accessories -1 nos., (e) 2 hp ,3 ph,415v,clorinator feeder with necessary accessories & level controller-1 no., (f) 32a mccb fdr for iep/misc purpose-1no., (g) 32a mccb for in house light-1no.,(e) plc feeder with necessary accessories-1no.( all spare & components as per vendor list of phed), supply and delivery at site of 15 kva, 3phase, oil cooled type servo motor operated copper wound line voltage corrector conforming to is-9815 (pt.-1)- 1994 suitable for un-balanced input voltage with following specification including first filling oil as per is-335 where applicable.a) input voltage:- 3 phase, main supply may or may not be balanced with respect to phase to phase- 200v-500v phase to neutral-115v-290v.b) output voltage:-3 phase balanced output voltage. phase to phase- 400vor 415v 1%, phase to neutral- 230v-240v 1% (provision should be made to adjust the variation of output voltage per phase by a variable pot oil within 5% of output).c) line regulation:- out put voltage should remain well with 1% of set voltage (from minimum to maximum i.e. either 400v. or 415v. supply variation).d) load regulation : output voltage should remain neutral well within 1% of set voltage be ( from no load to full load ) i.e. either 400v. or 415v.e) correction speed:- better than 35 volt / second.f) efficiency:- better than 95% on full load.g) cut off limit (minimum &maximum ) by limit switch with audio & visual.h) metering indication:- by selector switch provision should be made available to measure input mains supply and output voltage other stabilizer for load current measurement an ammeter with selector switch should be available.i) lamp indication :- for input & output should be provided. ( 3 lamps per side ).j) mcb protection: for input side.k) load protection : hrc fuse on each output phase should be availablel) output over shoot:- beyond 210v to . 255v /phase in case of manual mode & voltage protection :auto mode operation.m) visual indication for under voltage & over voltage of output.n) manual mode:- up & down correction with o / p voltage over shoot protection. beyond 210 v-255 v. per phase.o) nature of cooling:- oil cooled system.p) electric current over load protection .q) circuit for delay output .r) input high voltage cut-off above 500 v.s) mode of operation:- auto/manual with a provision to restore the normal working of the unit standby operation should be available in case of any electronic failure in auto mode., installation of mcc panel along with main switch, changeover, busbar chamber, cut out etc. all electrical equipment within the pump house, drawing of cable properly on suitable size gi cable tray on wall / as per direction of eic as per layout & ie rules and all connection with supply necessary materials, cable etc to complete the work, making arrangement with supply & fixing of materials for taking power within the pump house from wbsedcl end as per direction of eic. [for ph no - i, ii & iii], installation of above
 Loading, Please wait...

Connect us via What's Up