Get complete information related to latest Rubber Insulation Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Rubber Insulation Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Rubber Insulation Tenders.
Tender For bid to ras corrigendum : supply of mat. code: w90313146152, supply of thermal insulation of tip for 800 mw projects (material portion) , application of thermal insulation of tip for mat. code: w90313146152 (application portion)
Tender For supply of symphony venticool vc 20u , gi duct fabrication tata24 gauge sheet , thermal insulation 6mm , dual deflection aluminium grill , wheather proof canvas , ms cooler stand , l shape brackets , installation of unit , standard electrical and plumbing job , scaffolding , civil work wall puncture and wall finishing , transportation charges
Tender For biennial contract for the work of replacement of damaged thermal insulation of supply/ return air ducts and chilled water pipe lines, damaged return air boxing and damaged acoustic insulation of air conditioning system at various municipal properties of bmc. tender id- 2025_mcgm_1229888_1
Tender For supply of vrf or vrv airconditioning system for circle office madurai d d - si of vrf outdoor units , sitc of vrf idu , supply of cordless remote controller with receiver for 4-way cassette. , sitc of lcd touch screen , refnet joints , lifting and shifting charges of odu from gf to sf , lifting and shifting charges of odu from gf to tf , lifting and shifting charges of idu from gf to tf , pressure testing and pressure holding nitrigen , testing and commissioning of vrf systems , refrigerant pipe for vrf system , communication cable , drain piping with 9 mm thick nitrile rubberinsulation. , supply and charging of r-410a refrigerant , protective glass wool tape above the copper pipes , 2.5 inch pvc pipe for exposed coppe pipes area , sitc of underdeck insulation of ceiling , supply and fixing of ms angle iron, channel, chequered plates with 2 coats of primer, 2 coats of enamel paint and complete in all respect etc. , perforated cable tray , ventilation fans , gi round duct 22swg , powder coated extruded aluminium of 18 g disc valve , supply and installation of insulated flexible ducting, complete with connecting rings, aluminium foil tape, duct supports etc. , dx system biq , supply, installion and testing of interconnecting copper refrigerant pipe , electrical power cable from power mcb to odu , control cable between idu to odu with conduits and necessary fittings and accessories. , insulated pvc drain piping for indoor unit with 9 mm thick nitrile rubberinsulation. , comprehensive amc charges , buyback offer for acs
Tender For providing of repair and overhauling service - thermal insulation of hp and ip turbine of tg 01 during capital overhauling; thermal insulation of hp and ip turbine of tg 01 during capital overhauling; yes; buyer premises
Tender For corrigendum : supply of details description of specification for 100 watt led flood light - led rating in warm)/system wattage/rated power, led luminaire conformity to 15:10322/part 5/section 5/2012 latest and 15: 16107, (part 2/sec 1):2012, photo biological safety of leds used shall be as per 15:16108/2012 (exempt grou, types of led luminave as per the 15: 161070part-2/sec-11/2012, types of led modules as per the 25: 16103(part 2)/2012, led rating/system wattage/rated power, luminaire system efficacy bumen/watt), ingress protection (ip rating) as per 1 10322 (part 1): 1982 latest, mounting brackets fincluded, warranty for free replacement (in year), input operating voltage range and frequency, automatic higher cut off voltage above 300 volt, rated voltage, ac power factor at hill load, driver efficiency lin sage), total harmonics distortion (in lage), the total circut power shall not be more than 110 percent of the valve declared, by the manufacturer, led chip efficacy, colour temperature (+500), working life for led (minimum 50,000 buming hours as per lm-80 report), coltur rendering index(cri), optic lenise materal (uv stabilued) (write na or without optic lense supply), heat sink should be die-cast aluminum along with sufficient heat sink fins to desipate heat effectively, capacitor shall be ratail for a temperature of 105 deg. ceblus or better, junction temperature, operating temperature range, operating humidity range, short circuit protection, overload protection, over voltage geutection, reverse polarity, high voltage test (1.5 kv for ane minute between napply terminats and body of the, unit), insulation resistance between earth and current carrying part, the luminaire shad be protected against surges and transients (internal), the luminaire shall be protected against surges and transients of >/1kv, (external, the luminaires casing/housing (single piece housing) shall be pressure de catted, aluminum alloy with higher thermal.conductivity, the lummaire body must be corrosion resistant epoxy powder couted, all fasteners must be of stainless steel, the entire housing (both led section and driver section) shall be dust and water proof having ip 66 protection as per 15:10322 (part 11:1987 latest, luminaries light transparency should be of toughened glass, toughened transparent glass cover thickness, toughened glass shall not get discolored shall not suffer degration due to heat and agning within warranty period, number of electronic control gest (power sanoles), driver components shall be industrial grade or above, pci shall be fre grade minimum 0.8 to 1.0 mm thick or mom, the luminaires works on single phase three wires system (phase, neutral and, earth, suitable connector shall be provided for led connection between driver output, and led, length of st marked three cors wire (shall be provided along with supply of, materiall, ught source, manufactures name and and brand on the aluminium die cast body, manufacturer's name, model number, serial number, date of manufactiare (month-year), and int number as identification mark inside each unit and the outside of each packaging box, the operation characteristics voltage and power be marked inside of each led, system must have emi/emc compliance as applicable (test reports shall be furnish on demand by buyer/consignee)
Tender For thermal insulation in different areas of boiler and auxiliaries, esp, ducting, ms line, crh line, hrh line and id fan area of unit 7 dpps during overhauling period.