Get complete information related to latest Rubber Socket Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Rubber Socket Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Rubber Socket Tenders.
Tender For corrigendum : replacement of security equipment installations at dmde office complex under ge i rnd kanchanbagh, hyderabad - supply and fixing of electric fencing - 520 rm as specified below as per site requirement including taking down existing fencing with all connected accessories viz. energizer, boom barrier, hydraulic tyre killer, turnstile gate, swing lane barrier, fencing posts, fencing wire, insulators, door frame metal detector etc, complete all as specified and directed by engineer-in-charge., (a) general description(a) this scope involves, design, supply, installation, testing and commissioning of a non-lethal high security. electrical fencing for the purpose of deterrence, detection, and movement control of people / unwarranted trespassing into the premises for 520-meters perimeter length.(b) anyone who touches the power fencing when the system is armed shall be repelled by a short, sharp, painful, but safe pulsed dc high voltage shock. alarms shall be generated when someone touches, tries to climb through or tampers with the power fencing system., (c) the electric fencing shall be divided into two zones.(d) this system should be able to alert security personnel of an attempted intrusion and identify the zone around the perimeter of the site.(e) the electric fence is to be installed on the existing wall and the height of the fence will be 1.1 meters from top of the wall with 11 nos. of fence wires having 100mm gap between adjacent wires and it measure 1mtr.(f) electric fence posts are to be hot dip galvanized., (g) distance between strain fence posts spacing shall not exceed 50-meter nominal.(h) distance between intermediate fence posts spacing shall not exceed 3-meter nominal.(j) the electric fence shall incorporate uv stabilized intermediate post insulators.(k) warning signs shall be mounted around the fence line at intervals not exceeding 10m or at every turn on the physical fence.(l) dual zone fence energizer shall be installed to create 2 zones at site., (m) one dual zone led keypad shall be connected to fence energizer for local control and programming purpose.(n) a touchscreen controller should be placed in control room. fence energizer should communicate with touch screen controller over rs485 network.(o) the space between adjacent wires on the electric fence shall be no more than 10cm.(p) anti-climb configuration at strain points shall be provided. electric fence wire shall be looped around the strain post and connected back onto itself.(q) all high voltage impulse wiring shall be run in conduit separate from any other wiring.(r) the fence energizer shall be mounted in the weatherproof enclosure.(s) the energizer should comply with iec 60335-2-76 and is302-2-76 standards., (b) technical specification (electric fence system):energizerthe fence energizer should have the following minimum features: energizer should be dual zone with independent zone control. energizer should communicate with control room on rs485 network. energizer should have lcd display with background colours which changes according to the status of the energizer. green colour should indicate that all is fine, orange indicate that attention is required and red indicates an alarm condition., energizer should display the following information when specific codes are inserted from keypad: fence health on a scale of 1 to 9 for each zone independently, fence output voltage, fence return voltage, energy stored, capacity used and battery voltage. output energy 3.7 joule with 500 ohms load. pulse interval 1 sec. pulse duration should be less than 0.1ms. energizer should have apt - adaptive power technology functionality. which means the energizers should offer a unique technology to detect how much power a fence can accept and handle before it starts to arc and waste energy. this maximises the power on the fence and minimises false alarms., individual high voltage transformer for each zone. magnetic tag switch should be provided for on/off the ene
Tender For supply of micro controller based electronic speed indicating and recording system with speed signal c onfirming to rdso spec.no. mp-0.3700 .07 rev-7 august 2017.scale range 0-120,voltage-24 vdc each set consisting of following items. (1).recording cum indicator unit 01 no . (2).speed indicator -01 no . (3).puls e generator -01 no . (4).junction box-01 no . (5).connecting cable-01 (25 mtr) set of 05 nos similar to lax ven sytems model no.lax-2000d8. [ warranty period: 30 months after the date of delivery ]
Tender For controller / timer for eppfs, specification: input voltage: 110v ac/dc with 30% ripple (80v - 140v), output voltage: 24v dc, led indications: power on, relay on, dual supply voltage, range- 0 - 3sec /min, 0-10sec/min, accuracy setting: +/- 5% of f.s., mounting type: din rail mount, as per mmdts: 19027, rev - 3 or latest make: abb/bosch/honeywell/itc electrical components/selec/gic. [ warranty period: 3 0 months after the date of delivery ]
Tender For corrigendum : electrical lab equipment - colour digital storage oscilloscope 100mhz 1gs/s with fft, voltmeter 0-500v (analog ), voltmeter 0-500v (analog ) moving iron type, ammeter 0-1-2a (analog ) moving iron type, ammeter 0-2.5-5a (analog ) pmmc type, ammeter 0-5-10a (analog) moving iron type, wattmeter lpf dynamometer type, wattmeter 5-10a, 75-300-600v upf dynamometer type, megger 500v 1000m digital insulation tester, single person push button operation, bridge trainer kit, digital earth tester, energy meter 1-phase, trivector meter, dc motor cut section for lab application with manual, transistor characteristics npn-pnp trainer kit, trainer kit for turn off circuit of scr for laboratory purpose, smps trainer kit power supply : 230 v ac , 50 hz, ups trainer kit input voltage 180-260 volts, 50 hz, three phase induction motor cut section for lab application, three phase 6 cage induction motor trainer kit ,, universal motor phase single phase, stepper motor voltage 24-48 vdc, three phase squirrel cage induction motor trainer kit for speed control using auto transformer and vvvf method mains supply : three phase, 415v 10%, 50hz, lux meter, house & commercial wiring installation trainer, speed control of dc shunt motor trainer, speed control of dc series motor trainer, functioning of ct, pt and isolation transformer complate trainer, voltmeter and ammeter method for measurement of medium resistance., clamp meter, dc, ac & wave shaping circuit trainer, oil testing kit, transformer trainer 300 va, dc motor coupled to dc motor trainer, 3 phase squirrel cage induction motor trainer, single phase ac inducation motor trainer, dc motor coupled to 3 ph ac motor trainer, 3 phase ac integrated motor coupled to dc integrated motor setup (motor-generator setup):, electrical load power factor trainer (apfc), complete house wiring installation trainer, 3 phase squirrel cage induction motor trainer, control of 3 ph. squirrel cage induction motor trainer, 3 phase slip ring induction motor trainer, 1 ph. ac induction motor trainer, 3 phase salient pole alternator coupled to dc integrated motor setup (motor-generator setup) trainer, ac servo motor trainer with pid controller, dc servo position control trainer with pid controller, measurement of linear displacement by lvdt transduser trainer, strain gauge transduser trainer, temperature sensing transduser trainer, pressure measurment by piezo resistive transducer trainer, angular speed measurement using stroboscope & tacho meter transduser trainer, op-amp trainer, adc & dac circuits trainer, pelton turbine trainer (assemble & dismantle of micro hydro plant), microcontroller trainer 8051, solar and wind turbine trainer, fuse & mcb characteristics trainer, air circuit breaker trainer (dismantle acb), induction type electromagnetic relay trainer, electromagnetic over current reley i numerical relay trainer, percentage biased differential relay trainer, motor fault simulator trainer, on transmission line protection simulation trainer., lcr meter, digital multimeter, tachometer, wire striper, pliers, ball pen hammer, earth tester, took kit, soldering iron 25 watt with lead
Tender For supply installation testing and commissioning of 150 kva 3 phase servo controller automatic voltage stabilizer at centre for it deptt at university new campus
Tender For supply, installation and commissioning of induction heater (11/12kva) unit with roll sliding arrangement and intelligent micro controller-bas ed electronics controls for preheating of icf wheel bearings to make: precision model pih 2003 (11/12kva) or gm 12h (11/12kva) or inventum model hib- 03-rl(11 / 12kva unit). i. specification: - 1) power - 11/12kva, 2) voltage - 415/440v, 3) working frequency -50hz +/-10%, 4) residual magnetism - less tha n 2 a/cm, 5) power control -variable steps from 10% to100%, 6) temperature control - 0 to 250 deg. c minimum with microcontroller, 7) time control - 0 to 99 min ii. standard accessories: - 1) infrared cordless remote - 1no, 2) magnetic temperature probe - 1no., 3) standard horizontal yoke of size 80x80x500m m (apprrox)- 1no., 4) special equipment trolley - 1no., 5) operating manual - 2nos. 6. safety gloves - 1pair. iii. safety devices: - 1) mcp for over load protec tion, 2) thermal safety guard, 3) probe safety alarm for probe not connected for 4-6 sec, 4) yoke safety alarm for yoke not placed on vertical support for 4-6 s ec., 5) over range setting error with alarm for both time & temperature. 6) improper use of equipment error with alarm. [ warranty period: 30 months after the date of delivery ]
Tender For corrigendum : supply of esp electrical spares at 2x660 mw csctpp, chhabra - rapper controller - power module ador part no 6000012080 or equivalent , rapper controller - card cage ador part no 6000012130 or equivalent , rapper controller - output cards ador part no 6000012090 or equivalent , doc-iv microprocessor transformer rectifier controller of esp ador part ?? 6000011270 or equivalent , control transformer rk-1456, primary: 0-600v secondary: 0- 20v ador part no 4206007440 or equivalent , scr module, piv- 1400, thyristor module i(av)- 500a ador part no 4401001040 or equivalent , control transformer 415v/110v data-628 ador part ?? 4206006210 or equivalent , thermostate operate at 100 +/- 3 deg c ador part no 6000002590 or equivalent , the mcal -1 meter calibration card for ma ador part no 4601007510 or equivalent , mcal - 2,3 meter calibration card for kv ador part no 4601007120 or equivalent , hv dc voltage/current feedback assembly ador part ?? 4610009490 or equivalent , rapper controller panel - space heater with the thermostat ador part no 4210000110 or equivalent
Tender For wall mounted a/c timer switch twin ac controller to on and off 1.5 ton air conditioners one by one for time period of 1hr to 12 hrs. operating voltage: 230v ac, 50 hz frequency, 1 ph supply. ac on condition is to be shown by on lcd display. make m/s dynamic or equivalent. [ warranty period: 3 0 months after the date of delivery ]