Get complete information related to latest Safety Switch Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Safety Switch Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Safety Switch Tenders.
Tender For corrigendum : tender for supply of 11 and 33 kv overhead line material - 11 kv pin insulator complete , falling load 5kn , 11 kv disc insulator of tensile strength 45 kn , 33 kv pin insulator complete , falling load 10kn , 11 kv disc insulator of tensile strength 70 kn , 11 kv polymer air break switch complete with down rod , handle etc. , 33 kv polymer air break switch complete with down rod , handle etc. , 11 kv do fuse unit polymer , 33 kv do fuse unit polymer , 9 kv 5 ka metal oxide lighting arresters without gaps suitable for 11 kv system , 30kv 10ka metal oxide lighting arresters without gaps suitable for 33 kv system , aluminium conductor steel reinforce acsr rabbit conductor as per specifications , aluminium conductor galvanised steel reinforce acsr dog conductor , 200a , 12 kv rms brass connector , female , for gang operated airbreak switch , 200a , 12 kv rms brass connector , male , for gang operated airbreak switch
Tender For supply of 1)11 kv 200 a (tilting type) ab switch fixed contact (sab10001) assembly: fixed contact suitable for 11kv 200a (tilting type) ab switches shall be of high grade copper and capable of carrying the short circuit current of 16ka (min) and capable of carrying, rated normal current of the switch continuously the contact shall be 30x6x225 mm copper flat nickle plated and with 14swg guage phosphor bronze arcing horn suitable for the above switch 2) 11 kv 200 a (tilting type) ab switch moving contact (sab10002) assembly: moving contact for 11kv 200a (16 a load break) tilting type ab switch consisting of jaw cup of hdec 220x70x2mm and arcing horn of 5mm dia st. steel rod 30x6x100mm of with jumper pad to fix in jaw cup with studs and nuts and with st. steel springs (2 nos.) component wise breakup: i) moving contact cup assembly of hdec 220x70mm and 2mm thick. ii) moving contact jumper of hdec 30x6x100 mm. iii) st. steel arcing horn rod with fixing base 5mm dia and 225 mm long. iv) st. steel bolts & nuts and 3) supply of nylon bushes(sab00001) -reg
Tender For corrigendum : purchase of 11kv motorized ring main unit (3-way) - scada compatible3-way (ccv), 11kv, gas (sf6) insulated rmu with 2 nos. 630a load break switch and 1no. 630 a sf6 insulated vcb - 75 nos.
Tender For supply, installation, testing and commissioning of 2 no. chillers with cooling tower in central ac plant of main hospital at skims soura - sitc of vfd based, ahri/ eurovent certified, water-cooled, mono/ twin screw type chiller of capacity not less than 100 tr with allied items. the item shall be complete and ready to be connected with main headers in the existing central air conditioning plant of skims soura. the chiller shall be accompanied with microprocessor based control panel with all safety, switch gears needed for safe, smooth and hassle-free operation. the job includes laying of foundation as per oem recommendation which shall be not less than 6 inches above the finished floor level. the technical specifications are further detailed in annexure b., sitc electric-motor driven centrifugal pump for condenser and chiller sides having a discharge of 15 to 18 litres per second, head of 30 metres, 1450 rpm. the technical specifications are furhter detailled in annexure b., insulated chilled water piping (nitrile rubber insulation)supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water piping inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with following closed cell elastometric nitrile rubber of minimum 45 kg/ cum density, thermal conductivity 0.037 w/mk or better at 20 deg mean temperature class o insulation applied by suitable adhesive complete including repairing of damage to building etc. as per specifications and as required complete in all respect.note: the pipes of sizes 150mm & below shall be m.s. c class as per is: 1239 and pipes size above 150mm shall be welded black steel pipe heavy class as per is: 3589, from minimum 6.35mm thick m.s. sheet for pipes upto 350 mm dia., 300 mm (32mm nitrile insulation thickness), 250 mm (32mm nitrile insulationthickness), 150 mm (32mm nitrile insulationthickness), 125mm (32mm nitrile insulation thickness), 100 mm (32mm nitrile insulationthickness), 80 mm (32mm nitrile insulation thickness), 65 mm (32mm nitrile insulationthickness), sitc of butterfly valves with di body double flanged construction with epdm coated disc with long pitch and pn 16 pressure rating as per is 13095 (1991), 250 mm , 150 mm , 125 mm , 100 mm , 80 mm , 65 mm , providing and fixing of aluminum cladding of 0.63 mm thick sheet to the insulated pipelines including bends, valves, fittings, etc. the job includes grooving, providing and fixing of screws, washers etc. as per is : 2676 - 1981, 300 mm (32mm nitrile insulation thickness), 250 mm (32mm nitrile insulation thickness), 150 mm (32mm nitrile insulationthickness), 125mm (32mm nitrile insulationthickness), 100 mm (32mm nitrile insulation thickness), 80 mm (32mm nitrile insulationthickness), 65 mm (32mmnitrile insulation thickness), sitc of ductile iron non-return valve of following size with allied jobs as per site requirement. the valve shall be conforming to is-5312. pressure rating : pn16, 150 mm , 125 mm , 100 mm , sitc of y-strainer (ci) flanged end, of following size with allied jobs as per site requirement. pressure rating : pn16, 150 mm , 125 mm , 100 mm , 80 mm , sitc of balancing valve (ductile iron) of following size with allied jobs as per site requirement. pressure rating : pn16, 150 mm , 125 mm , sitc of t-strainer (c.i.) of following size with allied jobs as per site requirement. pressure rating : pn16, 250mm , sitc of fully stainless steel pressure gauge (bourdon beryllium copper, socket ss316l, case and bazel ss304), rugged construction with epdm blowback, safety glass. 0-40 kg/cm , dual display bar/psi or selectable, sitc in position the bi-metal dial thermometer temperature guage 4 dail size bsp (m) connection, ss case and ss wetted parts completer as required, sitc of air release valve of following size. air release valves shall be provided at all higher points in piping system for venting., 25 mm dia , sitc
Tender For special repair to ber improvement of ht switching system by replacement air break god switch with air break/sf6 based load break switch unit at mil stn gnr