Get complete information related to latest Scaffolding Service Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Scaffolding Service Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Scaffolding Service Tenders.
Tender For providing of testing service for on-board /commissioned equipment/ instrument related to plant - ndt; non destructive test of civil and steel structure at reep thorium plant, boiler house and other buildings as per scope of work and boq; nabl labs
Tender For supply of manpower and machinery for augmentation of existing erection works of contractors for mechanical equipment, steel structure and civil required for additional coal handling plant _10mtpa_ at rajmahal ocp, eastern coalfields limited.
Tender For supply , storage, handling, erection, installation, commissioning and testing of electrical equipment like power and control cable ,cable trays and supports lighting system and earthing system at rr site in oesc system. - supply and installation of following pre-fabricated and galvanized cable tray supporting structure materials as per specification, tender drawing (raps-1to8/ 01652/2053/ga) and reference drawings nos. kapp-3&4/ 21490/ 2002, 2003 & 2004/dd., 22 (22 mm dia) first rod with m22x55 long threading on one end & m 22 hex nut, isa 65x65x6, 22 (22 mm dia) rod, isa 65x65x8, ismc 75 channels, couplers (36 odx6 thk.), weld attachment (made of 75x10 thk. plate,320 long), swivel washer seat (46 x16 thk.), swivel washer (40 x16 thk.), iso 1234, 3.5x32 spilit pin, shear bolt m10x70 with hex. head & nut & washer, iso 1234, 3.5x20 split pin, washer (48 , is 2016), 3 mm thick l clamp with m8x30 mm long bolt, 2 plain washer, 1 spring washer and nut, 600mm long, 30 mm wide & 2.5 mm hot dip galvanized strip with two nos. of m8x30 mm long bolt, 4 plain washer, 2 spring washer and 2 nuts, supply and installation of following sizes of 1100v rated, cu conductor, xlpe insulated, frls pvc (st2) inner and outer sheathed un-armoured power cables along with wooden cable drums, 3cx2.5 sq.mm, 4cx2.5 sq.mm, 2cx2.5 sq.mm, supply and installation of following medium duty gi pipes/ heavy duty erw rigid conduits for routing cables from cable trays to distribution boards or to various field equipment or between equipment as directed by engineer- in- charge., 100 mm dia pipe, 65 mm dia pipe, 40 mm dia pipe, 25 mm dia conduit, supply and termination / connection of following types and sizes of 415v power cables at both ends along with cable glands, lugs, ferrules, clamps, hardware etc., and drilling of gland plates, crimping of lugs for termination of following cables (source end & load end considered separately)., supply of 3.5cx300, al, unarmoured, supply of 3.5cx185, al, unarmoured, supply of 4cx16, cu, unarmoured, supply of 3cx6, cu, unarmoured, supply of 4cx2.5, cu, unarmoured, supply of 3cx2.5, cu, unarmoured, supply of 2cx2.5, cu, unarmoured, termination / connection of 3.5cx300, al, unarmoured, termination / connection of 3.5cx185, al, unarmoured, termination / connection of 4cx16, cu, unarmoured, termination / connection of 3cx6, cu, unarmoured, termination / connection of 4cx2.5, cu, unarmoured, termination / connection of 3cx2.5, cu, unarmoured, termination / connection of 2cx2.5, cu, unarmoured, supply and termination of lugs for the following power cables (suitable bi-metallic connector shall be provided for termination of aluminium cable on copper bus bar) (neutral core lug shall be of suitable size)., lugs for 3.5cx300, al, unarmoured, lugs for 3.5cx185, al, unarmoured, lugs for 4cx16, cu, unarmoured, lugs for 3cx6, cu, unarmoured, lugs for 4cx2.5, cu, unarmoured, lugs for 3cx2.5, cu, unarmoured, lugs for 2cx2.5, cu, unarmoured, supply and installation of mortar based fire stops and fire break for all floor & wall openings of cable trays and in the run of cable trays and for sealing of electrical conduits including supply of structural steel support material if required., supply of 3 hr. rated fire stop for cable penetration in floor/walls + fire stop for cable/wire conduits & pipe sleeves, supply of 30 minute rated fire retardant compound (fire break) over cable, installation of 3 hr. rated fire stop for cable penetration in floor/walls + fire stop for cable/wire conduits & pipe sleeves, installation of 30 minute rated fire retardant compound (fire break) over cable, supply and installation of following sizes of gi conduits including supply & installation of all accessories like bends, elbows, couplers, hospital saddles, spacers, gi junction boxes, gi pull boxes, etc., and other accessories required to complete the job on wall/ column/ ceiling etc. as per specification and drawings. (the run
Tender For providing of testing service for on-board /commissioned equipment/ instrument related to plant - ndt; non destructive test of civil and steel structure at reep thorium plant, boiler house and other buildings as per scope of work; nabl labs
Tender For rate contract of ctvs items - rate contract of ctvs items :-, eptfe pericardial membrane 6.0 cm x 12.0 cms x 0.1mm, extra corpeal true membrane all size (complete set), eptfe pericardial membrane 12.0 cm x 12.0 cms x 0.1mm, expanded ptfe cardio vascular patch 0.5 mm size: 1.0 cms x 9.0 cm, expanded ptfe cardio vascular patch 0.5 mm size: 5.0 cms x 7.5 cm, expanded ptfe cardio vascular patch 0.5 mm size : 3.0 cms x 6.0 cm, expanded ptfe cardio vascular patch 0.4 mm size : 3.0 cms x 6.0 cm, expanded ptfe cardio vascular patch 0.6 mm size : 2.5 cms x 3.8 cm, expanded ptfe cardio vascular patch 0.6 mm size : 5.0 cms x 7.5 cm, ptfe ringed tubes it should be entirely made of ptfe it should not have an external wrap,it should have open pore. structure averaging 20 microns intermodal distance encouraging tissue ingrowth and making it soft and easy to suture.75cm long all sizes, bifurcated dacron tubes the prosthesis should used directly, without preparation before implantation the prosthesis should be strong, elastic, easy to pierce, and it should not fraythe wall should be provided with a colour guiding linewhen the prostheses are bent they should retain a lumen of circular shapethe water permeability should be 0-5 ml.cm-2.min-1should supplied in unit packagingit should sterilized by irradiation 50 cm long all size, dacron tubes the prosthesis should used directly, without preparation before implantation the prosthesis should be strong, elastic, easy to pierce, and it should not fraythe wall should be provided with a colour guiding linewhen the prostheses are bent they should retain a lumen of circular shapethe water permeability should be 0-5 ml.cm-2.min-1should supplied in unit packagingit should sterilized by irradiationall sizes 60 cm long, dacron tubes the prosthesis should used directly, without preparation before implantation the prosthesis should be strong, elastic, easy to pierce, and it should not fraythe wall should be provided with a colour guiding linewhen the prostheses are bent they should retain a lumen of circular shapethe water permeability should be 0-5 ml.cm-2.min-1should supplied in unit packagingit should sterilized by irradiationall sizes ,70 cm long, dacron patches (a) 1mm thickness implantable reinforcing felt for surgical applicationit should avoid possible incision of the stitchesit should be sterlized by radiationsize - 60 40mm, dacron patches (b) 1mm thickness implantable reinforcing felt for surgical applicationit should avoid possible incision of the stitchesit should be sterlized by radiationsize- 120 80 mm, knitted vascular patch with collagen (a) it should be easily cut to any shapeit should be strong elastic easy to pierce and it should not have frayit should be sterlized by irradiation sizes 100 100, knitted vascular patch with collagen (b) it should be easily cut to any shapeit should be strong elastic easy to pierce and it should not have frayit should be sterlized by irradiation sizes 13 80, knitted vascular patch with collagen (c) it should be easily cut to any shapeit should be strong elastic easy to pierce and it should not have frayit should be sterlized by irradiation sizes 13 100, knitted vascular patch with collagen (d) it should be easily cut to any shapeit should be strong elastic easy to pierce and it should not have frayit should be sterlized by irradiation sizes 35 100, valve implantation kit 1 kit, coronary surgery assistant kit 1 kit, complex congenital surgery kit 1 kit, venablock it should have 3cc of glue available in separate vials -it should have a catheter with a light source at the tip to assist in locating catheter tip position -it should have all accessories for injection of glue into applicator included - it should have ce and cdsco approval, atherectomy system -it should have infusion and aspiration port -it should be ready to use without any additional equipment -it should have adjustable rotational speed -it should have a 100cms catheter length, glow n tell tape glow n
Tender For erection of structure, equipment, control wiring, yard lighting, control-room & staff-quarter electrification etc. at 66 kv borisana s/s ta: kadi, dist: mehsana