Get complete information related to latest Screw Hooks Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Screw Hooks Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Screw Hooks Tenders.
Tender For bid to ras corrigendum : supply of erection materials for various projects - coupling mat: astm a105 galvanised to 10/15 microns size: 1/2" nptf/ pr. testing: 800 psi , elbow mat: astm a105 galvanised to 10/15 microns size: 1/2" nptf/ pr. testing: 800 psi , equal tee mat: astm a105 galvanised to 10/15 micronssize: 1/2" nptf/pr. testing: 800 psi , coupling mat: astm a105 galvanised to 10/15 microns size: 1" nptf/ pr. testing: 800 psi , elbow mat: astm a105 galvanised to 10/15 microns size: 1" nptf/pr. testing: 800 psi , equal tee mat: astm a105 galvanised to 10/15 microns size: 1" nptf/pr. testing: 800 psi , reducer mat: astm a105 galvanised to 10/15 microns size: 1" nptf to 1/2" nptf/ pr. testing: 800 psi , unequal tee/mat: astm a105 galvanised to 10/15 microns size: 2 x 1" nptf x 1/2" nptf / pr. testing: 800 psi , three piece union, matl: astm a105/galvanised to 10/15 microns/size: 1" nptf/pressure rating: 800 psi , three piece union, matl: astm a105/galvanised to 10/15 microns/size: 1/2" nptf/pressure rating: 800 psi. , ms channel 100 x 50 x 5 mm web thk/ms channel as per is 2062 gr.a/size. 100 x 50 x 5 mm web thk/running length 5 to 5.5 meters , ms angle 50 x 50 x6 mm is 2062/ms equal angle as per is-2062 gr.a/size:50 x50 x6 mm web thk./running length 5 to 5.5 meters , ms plate 10 mm thick is 2062/ms plate 10mm thick as per is 2062 e 250 , hr sheet 2.5 mm as per is 1079 , gi pipe-1/2" nb heavy grade as per is 1239 standard, threaded ends (1/2" npt) to be protected.running length - 6mtrs , gi pipe-1" nb heavy grade as per is 1239 standard, threaded ends (1" npt) to be protected.running length 6mtrs , gate valve rating:asa 150 lbs body: astm/b62 trim:ss 304 size:1/2nptf." , pipe a106 grb 2" nb sch 40 , u clamp-to suit 1/2" nb pipe with nuts and washers mat: cs, galvanised to 10/15 microns , u clamp-to suit 3/4" nb pipe with nuts and washers cs galvanised to 10/15 microns , u clamp-to suit 1" nb pipe with nuts and washers cs galvanised to 10/15 microns, forged reducer/as per ansi b16.11/material: astm a105/size: od of 1" nb x 1/2" nb-sw/class-3000/length = 100mm , forged coupling/as per ansi b16.11/material: astm a105/size: 1/2" nb-sw/class-3000 , forged expander/as per ansi b16.11/material: astm a105/size: 1/2" nptm to 3/4"nb-sw/class-3000/length = 100mm , forged coupling/as per ansi b16.11/material: astm a105/size: 3/4" nb-sw/class-3000 , forged unequal tee / as per ansi b16.11/matl:astm a105/size:2 x 1/2" nb-sw to 1/2"nptf/cl:3000 , forged unequal tee/as per ansi b16.11/matl:astm a105/size:2 x 3/4" nb-sw to 1/2"nptf/cl:3000 , forged coupling/as per ansi b16.11/material: astm a105/size: 1/2" nb-sw/class-6000 , forged reducer/as per ansi b16.11/material: astm a105/size: od of 1 nb x 1/2" nb-sw/class-, 6000/length = 100mm , forged reducer/as per ansi b16.11/mat: astm a105, size: od of 1" nb x 1/2" nb-sw/class-3000 , forged reducer/as per ansi b16.11/mat: astm a182 f22, size: od of 1" nb x 1/2" nb-sw/class-6000 , forged expander / as per ansi b16.11/mat: astm a105, size: od 22 mm x 3/4" nb sw/class-3000 , condensate pot matl: astm a106 gr.c/astm a105 size: 88.9 x 17.6 mm thk. connection: process -15nb-sw/instr.: 15nb-sw vent-1/2" plug , 3 way valve manifolds material:ss316/size:1/2"nptf pr. testing 3000 psi , 3 way valve manifolds material:s5316/size:1/2"nptf pr. testing 9000 psi , 5 way valve manifolds material:ss316/size:1/2"nptf pr. testing 3000 psi , 2-way manifold valve material:ss316/size: 1/2" npt(f) x 1/2" npt (f) pr. testing 3000 psi , ss316 tube 1/2" od x thickness 2.1mm , male connector (dfdc) material: ss316 siez:1/2"nptm x to suit 1/2" od ss tube , tube fitting double ferrule double compression/mat. s5316/size 1/2" bspf x to suit1/2" od s.s. tube , tube fitting: 55316 tube union 1/2" , nut & tail/ male stud coupling 1/2"npt(m) x m20 x 1.5mm washer, astm a105. , ss stud bolt with nuts (size-m16, length-90 mm) , flexible hose of ss braided on nylon size-1/2" od x 1 mtr. with clamps. both end with adopter of 1/2"
Tender For supply of supplyuing transformer , itc of transformer , rs joist h beam pole , pcc pole , erection of steel tubular or rail pole , erection of pole , m s angle and channels , supplying m s angle and channels , m s angle , g i pipe , potencial transformer , resistor type lightning arrestor , gang operated air break switch , 11 kv do fuse , 11kv pin insulator , acsr weasel , danger notice plate , g i plate earthing , g i strip in g i pipe , g i strip , g i pipe earthing , g i wire , medium class pvc conduit , 11kv aerial bunched cables , xlpe aerial bunched cables , ht cable end termination , lt cable end termination , energy meter board , suspension for lt abc cable , dead end , gi clamp , kit kat , cantilever angle , loop earthing
Tender For supply of material and erection of equipments and structure for construction of 01 no. 132/33kv bay at 132kv sub-station harraiya under electricity transmission division-i, basti - supply, pale fencing, earthing 40 mm ms rod for main earthing, earthing 40 mm ms electrodes ( 3 meter longs), m.s. flat for earthing 75x10, m.s. flat for earthing 50x6, air conditioning system, two ton window ac with all accessories and stabilizer(not less than 5kva capacity) with installation, single tension fitting suitable for, acsr moose, acsr panther, single suspension fittings suitable for, acsr moose, acsr panther, pg clamp suitable for, moose/ moose, moose/panther, panther/panther, bus post clamp suitable for, panther, twin panther, moose, lightening fixture led luminaries type sl-di as per tech specifications, work, erection of main & auxiliary structure consisting of column. beam peak, mast etc and auxiliary structure of installation of cts, la etc. the job consists of shifting of all materials from store to site of erection and erection of structures as per drawing with the help of gi nut & bolts, flat & spring washer with matching the hole, cutting & matching of member if required, including cost of all men and t&p excluding gi structure nut & bolts to complete the work. gi structures, nut & bolts and washer will be provided by department free of cost., erection of 145 kv equipments, 145 kv bus/line and tandom isolator, 145 kv current transformer, 145 kv post insulator, 120 kv lightening arrestor, 145 kv ct junction box, 132 kv transformer (c&r) panel, 145 kv sf-6 circuit breaker, erection of 33 kv equipments, 33 kv vacuum circuit breaker, 33 kv isolator, 33 kv current transformer, 33 kv lightening arrestor, 33 kv ct junction box, stringing of three phase jack bus 132 kv with panther conductor. the work includes cutting & bending of conductor, fixing of single/double bolted type tension fitting/suspension. hoisting of disc insulators and shifting of material from store*site to erection site and all other associated work to complete the job satisfactorily as per instruction of engineer incharge., 132 kv jack bus for transformer, 132 kv making of u jumpers, equipments interconnection jumpering with main bus bar. job includes bending of conductor in proper shape tightening with the help of clamps and all other associated work to complete the job., transformer bay for 132 & 33 kv side, laying and termination of following size control cable in trench/cable trays from different control room c&r panels to switchyard equipments (132/33 kv cb, ct their junction boxes . transformer marshalling etc) in 132/33 kv switchyard as per cable schedule including carriage of cable drum from store and all other associated work., 2cx2.5mm2, 4cx2.5mm2, 6cx2.5mm2, 10cx2.5mm2, termination of control cable ( per termination), cutting strengthening bending and laying 700 mm/500 mm below inside ground and above ground of following size m.s. flat for earthing of main and auxiliary structure and equipments including welding with main earth mat and with objects to be earthed, excavation trenches and back filling painting and all other associated work as required to complete the work satisfactorily. m.s. flat will be providing by the contractor free of cost., 75x10 mm, 50x6 mm, making delta earthing of 120 & 33 kv la by fabrication of 03 nos 3 mtr m.s. round bar ( 36/40 mm dia) electrode it piercing inside the ground and connecting all 03 nos electrodes with 36/40 mm m.s. round laying around as per drawing painting the jointing with 75x10 mm m.s. round bar laying around as per drawing. painting the joints with black japan paint of good quality after proper cleaning of joints by wire brush ms round bar will be provided by dept, free of cost., dismantling of 250k.va 33/0.4k.v station t/f work includes opening of jampers/cable connection/cutting of earthing etc., laying of 300/400mmsq. 3.5core power cable from control room t
Tender For corrigendum : supply, dismantling erection testing and commissioning of existing hydraulic rail clamp assembly for thyssenkrupp make stacker cum reclaimer of conveyor 8a installed at 4x210 mw chp i at sgtps, mppgcl, birsinghpur
Tender For corrigendum : daivya apda work under edd fatehabad - carriage of following from 132 kv taj agra to 33/11 kv substations through the kacha and pakka road including the work of its loading and unloading at the respective ends including the cost of arrangement of labour, t&p, carrier etc. required for proper completion of work.(distance 00-70kms.) 8.5/9/11 mtr/13mtr.. long pcc/stp poles., carriage of following from 132 kv taj agra to 33/11 kv substations through the kacha and pakka road including the work of its loading and unloading at the respective ends including the cost of arrangement of labour, t&p, carrier etc. required for proper completion of work.(distance 00-70 kms.) 11 kv x-arms, weasal conductor, g.i wire,disc insulators, pin insulators, clamps and other required line material, if any., carriage of following from realted 33/11 kv substations to site of work i.e. pit point through the kacha and pakka road by using manual labour or tractor/hydra as per site requirment including the cost of arrangement of labour, t&p, carrier etc. required for proper completion of work.(distance 00-10 kms.) a) 8.5/9/11 mtr/13mtr.. long pcc/stp poles., carriage of following from realted 33/11 kv substations to site of work i.e. pit point through the kacha and pakka road by using manual labour or tractor/hydra as per site requirment including the cost of arrangement of labour, t&p, carrier etc. required for proper completion of work.(distance 00-10 kms.)d) 11 kv x-arms, weasal conductor, g.i wire,disc insulators, pin insulators, clamps and other required line material, if any., cutting of kharanja/mettalic road/concrete portion while digging pit for erection of pcc/stp poles, stays rod and giving the exact shape after exicution work as per direction of supervising engineer. it includes the cost of labour, t & p, carrier etc reauired for proper completion of work., replacement & erection of damaged poles of lt lines by digging of pits and dismantling of all 11kv/lt accessories from the existing / damaged pole and erection of single new pole including fitting all accessories., replacement of damaged poles ht lines by digging of pits and dismantling of all 11kvkv accessories from the existing / damaged pole and erection of single new pole including fitting of all accessories., replacement of damaged poles 33 kv lines by digging of pits and dismantling of all 11kv/33 kv accessories from the existing / damaged pole and erection of single new pole including fitting of all accessories., grauting of new erected 8.5 mtr/ 9 mtr/11mtr/13mtr long pcc/stp poles, recostructions of damaged double pole (saction) on 11 kv lines by dismantling of t/f, opening of all accessories of lt s/s then removing damaged poles by digging earth pit(s), erecting new poles then fixing of of lt s/s accessories such as dropper channel, t/f base, disc insulators with fitting and other 11 kv accessories etc., required for proper completion of work., replacement of damaged double pole structure on 33 kv lines dismantling of t/f, opening of all accessories of lt s/s then removing damaged poles by digging earth pit(s), erecting new poles then fixing of of lt s/s accessories such as dropper channel, t/f base, disc insulators with fitting and other 11/33 kv accessories etc., required for proper completion of work., erection of stays its tightning, binding, nozelling etc. of stay wire with stay and stay clamp of pole as per requirement of work at site., re- sagging and stringing of existing conductor in 11kv/ /lt line as per direction of supervising engineer including the cost of arrangement of labour,t&p, carrier etc. required for proper completion of work a) acsr weasel conductor., b)acsr dog conductor., c) 50/95/120 sqmm abc., removal of following damaged conductor of existing damaged line including opeing of jumpers and line accessories etc making bundle, stacking at safe place and its relaying after completion of pole work, including fixing of acce
Tender For supply of (ami no.23s13/25-26) set of (4 )3.5 / 4mm polyaxial screws/hooks (interchangeable) + 2 tapered rods (as per attached specification) ]
Tender For supply, fabrication, welding/joining, erection and testing of hdpe piping from kgs 3 and 4 to kaiga 5 and 6 area. - supply items (schedule-a), 100 nb equal tee sch 40 astm a 234 gr. wpb sml bw ansi b 16.9, 1oo nb sorf flange 150 # astm a 105 ansi b 16.5, 100 nb blind flange 150 # astm a 105 ansi b .16.5, 100 nb gate valve manual op. flange end 125/150 # sa 216 gr. wcb ansi b 16.34, 100 nb ball valve manual op. flange end 125 /150# hdpe, suit to 100 nb,sa 105, 150 # ansi b 16..5 back ring flange, flange end mechanical type flow totalizer 150# (range 150000 to 200000 cu. mtr.capacity) to suit to 100 nb sa 105 flange 150 #, ansi b 16.5. flow meter totaliser specification, dn-110 hdpe pipe is 4984 gr. pe 80 pn 6, dn-110 hdpe 90 degree elbow, is 4984 gr. pe 80 pn 6 as per is 8008, dn-110 pipe /stub end, 1s 4984 gr pe 80 pn 6 as per is 8008., 100 nb cs back ring flange astm a 105 as per ansi b 16.5 150#, dn-110 hdpe equal tee, is 4984 gr.pe 80 pn 6, as per is 8008, dn-50 hdpe cap, is 4984 gr. pe 80 pn 6, as per is 8008., hexagonal headed bolt, nut with washer 85 mm long is 1363 gr. 6.3 /is 3757 gr. 8.8, ismc 100 is 2062 , e 250 gr. a, 12 mm thick plate is 2062 , e 250 gr. br, 110 nb ms u clamp 25 mm wide x 3.5 mm thick, 100 nb m 12 u bolt is 2062 e 250 gr. a, m 10 x 100 hst/faz, 1.6 mm thk caf gasket 100 nb is 2712 gr. w/3, erection item (schedule-b), butt fusion welding / joining and laying of dn- 110 hdpe pipe, is 4984, grade pe 80, pn 6 both under ground and above ground., butt fusion welding / joining and erection of dn-110 90 degree elbow, hdpe, is 4984, grade pe 80. pn 6 ( inclusive of welding/fusion of both end), butt fusion welding / joining and erection of dn-110 hdpe equal tee, is 4984, grade pe 80. pn 6 ( inclusive of welding/fusion of three end), butt fusion welding / joining and erection of dn-110 hdpe pipe end /stub end is 4984, grade pe 80. pn 6, butt fusion welding/joining and erection of dn-50 hdpe cap is 4984 grade pe-80 pn-6, installation of 100 nb hdpe ball valve without welding., fabrication , erection , welding, inspection,surface cleaning & supply and application of hb chlorinated rubber zinc phospate primer paint in two coats to minimum 100 micron dft and supply and application of hb chlorinated rubber finish paint in two coats to 60 micron dft for cs structural steel support and components., installation of anchores m10 x 100 mm hst/faz including handling,scafolding,labour & tools., removing & reinstallation of precast concrete slab 0.3 m (l) x 1.350 m (w) x 0.1 m (t), excavation and backfilling of excavated trenches with the soil after completion of installation of pipe lines and testing including levelling/grading, compaction to the required level 1.5 m (d)x 0.8 m (w), sand bedding 50 mm depth x 400 mm width for underground hdpe piping including supply of sand., dismantling of existing dn-50 hdpe piping including breaking of existing cement concrete ( 0.7 cub.mtr) & pcc to be done after breaking and removing of existing cement concrete, including tools, labour & disposing of unservicable material as directed by eic, carefully removing the korean grass along with soil of 100 mm to 250 mm depth and 1500 mm width including replacing the same removed korean grass along with soil after laying hdpe line along with tools & tackles,watering of grass,dressing of area etc.in all complete as per direction of eic
Tender For supply of electric materials in nagar parishad unhel - supply of electricals material 2025-26, tube rod 24 wt surya company, choke 24 watt surya company, tube rod 36 wt surya company, choke 36 watt surya company, tube light fixture complete with tube, tube light cover, tube light clamp 1 complete, stater 40 wt, holder (tube light holder) for 24 w small size, halogen fitting complete set 70 wt m.h.( ), halogen fitting complete set 150 wt m.h.( ), halogen fitting complete set 250 wt m.h.( ), halogen fitting complete set 400 wt m.h.( ), halogen rod 1000 wt, halogen side holder, aluminium wire 4mm, aluminium wire 8mm, cable four core armed 8mm aluminium, cable 4mm copper 3 core, copper wire 1 mm, copper wire 1.5 mm, copper wire 2.5 mm, m.s.b. condenser 20/33 mfd, tape roll isi mark, clemp (ii) 1" gi pipe engle (iron) complete (4kg), clemp (ii) 1 1/4 gi pipe engle (iron) complete (4kg), ceiling fan 1200 mm (havells), coller pump, exhaust cooler complete, fresh air fan 9 and 12 , wall fan 16 (havells), fiber body cooler 18" heavy (havells), cooler condenser 4 mfd, cooler condenser 6 mfd, street light timer control panel box complete.(digital 24hr. contactor rating 32/tp, mcb rating 40spn), led street light with fixture 50 watt surya company 2 year warranty, led street light with fixture 90 watt surya company 2 year warranty, led street light with fixture 50 watt crompton company 2 year warranty, led street light with fixture 90 watt crompton company 2 year warranty, led street light with fixture 50 watt havells company 2 year warranty, led street light with fixture 90 watt havells company 2 year warranty, led street light with fixture 50 watt bajaj company 2 year warranty, led street light with fixture 90 watt bajaj company 2 year warranty, led street light with fixture 50 watt eon company 2 year warranty, led street light with fixture 90 watt eon company 2 year warranty, led street light plate 50 wt surya company, led street light plate 50 wt crompton company, led street light plate 50 wt havells company, led street light plate 50 wt bajaj company, led street light plate 50 wt syska company, led street light plate 90 wt surya company, led street light plate 90 wt crompton company, led street light plate 90 wt havells company, led street light plate 90 wt bajaj company, led street light plate 90 wt eon company, led street light driver 50 wt surya company, led street light driver 50 wt crompton company, led street light driver 50 wt havells company, led street light driver 50 wt bajaj company, led street light driver 50 wt syska company, led street light driver 90 wt surya company, led street light driver 90 wt crompton company, led street light driver 90 wt havells company, led street light driver 90 wt bajaj company, led street light driver 90 wt eon company, board (wood)(3inch *4 inch), tubular pole 6 mtr. with arm and fixing complete, tubular pole 8 mtr. with arm and fixing complete, tubular pole 10 mtr. with arm and fixing complete, armored cable 2 core 4mm, g.i. pipe 32mm, cement pole 8 mtr. with arm, angle brackets and fixing complete, casing patti, switch, indicator, fuse, holder, ceiling rose, power socket, regulator, m.c.b. box, screw, ( . . .), (100 ./ .), , 05 , , . ., , , 10 , 06 , 04 , 08 , 12 , 3 , , , . . ., (63 ), . . . 6 . ., . ., (08/10), . . . 10 , . . . 20 , . . . 25 , . . . 30 , . . . 35 , 60 , 100 , 200 , 3 , 8 . .4 , 10 . .4 , 1.5 . ., 2.5 . ., 11000 , ( ) 11000 , , 20-22, , 11000 , , 150 , . . . 50 , . . . 30 , 100 (havells), 200 (havells), , . . . , . . . 50 , . . . 50 , . . . 72 , steel tubuler poll 410-sp-11, 8mtr. hight, erection of steel tubuler pole / steel rail pole/ h-beam in cement concrete length upto 10 mtr., erection of rcc/pcc pole including excavation and rifilling, unarmoured 16 sqmm xlpe cable 1100 volt 1 core, unarmoured 25 sqmm xlpe cable 1100 volt 1 core, unarmoured 10 sqmm xlpe cable 1100 volt 2 core, unarmoured 16 sqmm xlpe cable 1100 volt 2 core, unarmoured 50 sqmm xlpe cable 1100 volt 3