Web Analytics Made Easy - StatCounter

Sealed Compressor Tenders

Get complete information related to latest Sealed Compressor Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Sealed Compressor Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Sealed Compressor Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

Central Government/Public Sector

CTN :43480359 Due date: 15 Jan, 202615 Jan, 2026 NA
Tender For supply of hermetically sealed compressor scroll type 3 phase 415v 50 hz conf to rdso spec. no.rdso/pe/spec./ac/0061-2005 (rev-1) suitable for roof mounted ac package unit of ac coaches of refrigerant r-407. [ warranty period: 30 months after the date of delivery ]

CTN :43477656 Due date: 28 Jan, 202628 Jan, 2026 NA
Tender For supply of sealed compressor suitable for r-600

Central Government/Public Sector

CTN :43395255 Due date: 09 Jan, 202609 Jan, 2026 NA
Tender For corrigendum : procurement of hermitically sealed compressor for package ac units stimain plant and swas for ntpc simhadri

Central Government/Public Sector

CTN :43405967 Due date: 22 Jan, 202622 Jan, 2026 NA
Tender For supply of hermetcally sealed compressor

CTN :43382770 Due date: 09 Jan, 202609 Jan, 2026 NA
Tender For supply of demand of stores d d--pvc copper cable single core and multi core circular sheathed cable with rigid conductor (v2) as per is 694 (q2) , outdoor unit for split ac 1 point 5 ton without compressor , complete outdoor unit for split ac 1 point 5 ton without compressor , suction or liquid line valve of size 1by 4 dia , suction or liquid line valve of size 3by 8 dia , insulation of size 1 by 4 dia for copper pipe , insulation of size 3 by 8 dia for copper pipe , indoor unit for split ac 1 point 5 ton , without compressor outer complete unit for window ac 1 point 5 ton , bracket for holding outdoor unit , pencil cell for ac remote , rotary type sealed compressor of cap 1 point 5 tr , indoor unit pcb suitable for all weather type 1 point 5 ton inverter ac , reciprocating type sealed compressor of cap 1 point 5 tr , reciprocating type sealed compressor of cap 2 tr , front grill for window type ac 2 tr , teflon tape , capacitor 50 add 6 mfd , capacitor 80 by 100 mfd , indoor blower motor for split ac 1 point 5 ton , crca sheet steel plug and socket distribution board 20 amp , exhaust motor for split ac 1 point 5 ton , outdoor unit pcb suitable for all weather type 1 point 5 ton inverter ac , flexible pvc drain pipe for ac , refrigerant gas r 22 , copper pipe of size 1 by 2 dia , copper pipe of size 1 by 4 dia , refrigerant gas r 134a , exhaust motor for split ac 1 point 8 or 2 ton , outdoor unit pcb suitable for all weather type 1 point 8 or 2 ton inverter ac , axial fan 14 x 4 inches for water cooler , starting relay 1 by 22 , starting relay 1 by 24 , suction or liquid line valve of size 5 by 8 dia , rotary type sealed compressor of cap 2 tr , capacitor 36 mfd , indoor unit pcb suitable for all weather type 1 point 8 or 2 ton inverter ac , insulation of size 1 by 2 dia for copper pipe , insulation of size 5 by 8 dia for copper pipe , indoor unit for split ac 2 ton , without compressor outer complete unit for window ac 2 ton , copper pipe of size 3 by 8 dia , copper pipe of size 5 by 8 dia , ac cleaning spray foam type 500 ml , a c descaling agent for split ac cap 1 point 5 or 2 tr , tpn db 4 way , vtpn db 4 way , spn db 8 way , spn db 12 way , electric exhaust fan 300 mm , electric ceiling fan with bldc motor 1200 mm , indoor blower motor for split ac 2 ton , automatic fire suppression system for electric panel 4 kg , automatic fire suppression system for electric panel 2 kg , automatic fire suppression system for electric panel 1 kg //bid details2 / 44

Central Government/Public Sector

CTN :43306328 Due date: 13 Jan, 202613 Jan, 2026 NA
Tender For tender for supply of sitc of air conditioner : : -supply installation testing and commissioning of 2tr 24000 btu per hour minimum bee 3 star rated confirming to is 1391 part 2 2018 inverter type cassette split ceiling mount air conditioner having wireless remote controller led display for indoor unit motorized vertical horizontal swing controls air filters auto restart with memory features inbuilt drain pump rotary scroll hermetically sealed compressor and initial charge of eco friendly refrigerant condensor and evaporator coils of copper material suitable for operation on 230v 10 single phase 50hz ac power supply. the indoor unit shall be suspended from the ceiling using threaded rods- including clamps bolts nuts etc and the outdoor unit shall be mounted on floor complete as required. , supply installation testing and commissioning of 2tr 24000 btu per hour and iseer value five star rated and compliance with is 1391 part 2 2018 wall mounted inverter type hi wall split cooling inverter air conditioner having wireless remote controller with led display hermetically sealedscrollrotary compressor and eco friendly refrigerantinitial charge of refrigerantcondensor and evaporator coils of copper material air filter with auto swing auto restart features suitable for operation on 230v single phase 50hz ac power supply. the indoor unit shall be fixed rigidly on wall using necessary frame the outdoor unit shall be mounted on floorlaying and interconnection of standard-length copper refrigerant piping as supplied by the oem between indoor and outdoor units complete in all respects as required. necessary drilling of hole and finishing the same to match for the surrounding as required. , supply and laying of soft drawn copper refrigerant pipe of suitable size for 2tr air conditioners for interconnection of suction and liquid lines between indoor and outdoor unit with tubular thermal foam insulation including necessary brazing jointing etc as required for cassette split air conditioner as required for item no. 1 2 , supply laying of 4c x 2.5 sqmm frls pvc insulated 1.1 kv grade pvc sheathed multistrand flexible copper cable confirming to is 7098 pt 1 1988 along with the refrigerant lines for connecting indoor and outdoor units , supply and fixing of 25 mm dia minimum thickness of 1.2mm pvc drain pipe along with accessories and necessary clamps with an u trap at the end as required. , supply and fixing of 75mm dia minimum 1.8mm thickness pvc covering pipe using necessary bend collor clamps threded rod supports accessories etc for laying copper refrigernt line electrical cable and drain line as required. , supply and installation of floor mounted powder coated ms 25x25x5mm l angle frame including clamps bolts nuts vibrating dampers as required for mounting of outdoor unit. , drilling of hole using core cutting machine of size up to 100 mm dia in concrete stone wall ceiling for laying refrigerant lines etc and finishing the same with cement mortar to match for the surrounding as required after laying , dismantling shifting of old 2tr cassette split air conditioner having indoor and outdoor units associated refrigerant pipes electrical wires and drain pipes including pump down of refrigerant. , making of necessary alteration of existing gypsum false ceiling for installation of cassette air conditioner indoor units including necessary aluminium channel support gypsum board necessary accessories including painting to match for the existing false ceiling.
 Loading, Please wait...

Connect us via What's Up