Get complete information related to latest Seals Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Seals Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Seals Tenders.
Tender For corrigendum : supply of stbd gearbox spares for icgs sajag - rtd for output shaft radial bearing radial bearings aft and fwd t1 and t2 , radial bearing o 280x260 , rtd for input shaft radial bearings aft and fwd t3 and t4 , rtd for sea water inlet and outlet temp t13 and t14 , rtd for thrust bearing of input pinion shaft aft and fwd t9 and t10 , bidirectional speed sensor for obyp shaft speed 0 to 300 rpm ss1 , magnetic pick up sensor for engine speed 400 1150 ss2 , magnetic pick up sensor for fi fi speed 0 to 1800 rpm ss3 , hp line filter element , oil seals for input shaft , oil seals for input pinion shaft , oil seals for pto output prop side , oil seals for pto input engine side , oil seals for output shaft engine side , oil seal for output shaft pro side , oil seal for sw pump drive assembly , input pinion shaft stbd
Tender For supply of e-285: servicing of filling valves and replacement of air and lub oil inlet pipe lines (size= 25mm) , e-284: servicing and overhauling of portable lub oil pump is to be carried out and proved. , e-282: obm gear box produces abnormal sound. to be overhauled make: mercury 25hp , e-283: 02 nos domestic ro plant not producing fw. servicing to be carried out including spares , e-281: 06 nos fire hydrants no holding pressure. locking pins and seals to be replaced and proved
Tender For enquiry for procurement of rubber seals for various butterfly valves installed in turbine area of unit no. 1 and 2 at 2x600 sstpp, mppgcl dongalia.
Tender For bid to ras corrigendum : supply of control valve normal service for 2x800 mw ustpp mahan phase ii singrauli - asv-8 dea. pegging from aux. steam header , crhv-6 dea. pegging from crh line , cdv-26 main condensate control , cdv-23 low load condensate control , cdv-39 gsc min. flow recirculation , cdv- 43 excess return to cst , cdv-72 condensate for valve gland sealing , drv-2 and drv-8 hph-8a and 8b normal drain to hph-7a and 7b , drv-5 and drv-11 hph-8a and 8b alt. drain to ft-a , drv-15 and drv-22 hph-7a and 7b normal drain to deaerator , drv-18 and drv-25 hph-7a and 7b alt. drain to ft-a , drv-31 lph-3 alt. drain to ft-b , drv-48 deaerator overflow to ft-b , drv-53 and drv-59 hph-9a and 9b normal drain to hph-8a and 8b , drv-56 and drv-62 hph-9a and 9b alt. drain to ft-a , drv-65 lph-4 normal drain to lph-3 , drv-82 lph-5 normal drain to lph-4 , drv- 68 lph-4 alt. drain to ft-b , drv-85 lph-5 alt. drain to ft-b , dmv-43 dm normal mu to hotwell , drv-28 drip pump discharge control , asv-2 aux. steam to bfpts , crhv-2 crh steam to bfpts , dmcw-25 dmcw system for plant auxs , 1 by 4 inch ss tubing - 12 meter for each tag , ss fittings for connection to air filter regulator - for each tag , ss fittings for connection to air lock relay - for each tag , ss fittings for connection to ia header isolation valve - for each tag , ss equal tee - for each tag , ss 1 by 2 inch npt - m x 1 by 4 inch od tube connector - for each tag , commisioning spares - gaskets and gland packing , valve diagnostic and configuration software , cv test charges , pneumatic diaphragm for diaphragm actuated valve or equivalent item applicable for selected actuator type shall be provided - 2 nos. for each type of actuator , actuator seal kit for pneumatic cylinder actuated valve - 2 nos. for each type of actuator , gland packing - 1 set for each type of control valve , plug, seat, cage, stem etc. - 1 set for each type of control valve , retainer ring, seal ring etc. - 1 set for each type of control valve , gasket - 2 sets for each type of control valve , control valve or power cylinder positioner complete set - single acting - 10 percent of total quantity used in the system or minimum 2 nos. whichever is more for each type and model. , control valve or power cylinder positioner complete set - double acting - 10 percent of total quantity used in the system or minimum 2 nos. whichever is more for each type and model. , complete set of solenoid valve for pneumatic type on off valve or power cylinder - 2 nos. for each type and ratings , position limit switch for pneumatic type on off valve or power cylinder - 10 nos. for each type and ratings , air lock relay - 10 nos. for each type , signal air booster unit - 2 nos. for each type