Tender For amit make hvac spare smoke sensor as per rdso specification no.rdso/pe/spec/emu/0196-2019 (latest) along with latest annexure and addendum/corrigendum to m/s.amit item code t18009 suitable to vb rakes as per icf/chennai price agreement no.08/25/1118/1009, dated 12/06/2025 to item no.28 and pl no 31908391. it is changed as condition basis in vande bharat rake no.6. warranty period: 30 months from the date of supply. [ warranty period: 30 months after the date of delivery ] ]
Tender For bid to ras bid to ras supply of rrc for addressable fire detection system onboard in ships and yard crafts at nsry karwar -repairs to main control panel , repairs to repeater panel , repairs to control cards , repairs to ionization smoke detector , repairs to multi sensors , repairs to temperature heat detection sensor , repairs to flame detector , repairs to manual call point , repairs to front panel switches , repairs to alarm bells lights hooters , repairs to internal circuit wiring , repairs refurbishment of ups , repairs to cabling from main control panel , reprogramming of the pcbs
Tender For supply of analogue addressable multi sensor detector with multiple sensitivity (adjustable at site) levelse.g. smoke, heat, rate of rise heat etc, programmable for timed automatic sensitivity selection with base, and other accessories as required.as per rdso specification no. rdso/spn/217/2021 ver 3.0 or latest. [ warranty period: 30 months after the date of delivery ]
Tender For tender for supply of sitc and maintenance of addressable fire alarm and detection system at uco bank - supplying , installing , testing and commissioning approved make microprocessor based multi-loop , networkable addressable 02 loop fire alarm control panel with minimum 10 inch 1024x600 resolution lcd with touch capability , including audible and visible feedback , backlit by a long life , solid-state lcd. it shall also include a full qwerty-style keypad on the color , touchscreen display. the display shall have the ability to scroll events by type (i.e. fire alarm , supervisory alarm , trouble , etc) using the touchscreen with customizable buttons , 10000 history events & autolearn feature for programming. the system can be supported upto 2000 generation zone & 2000 logic zone & 50 releasing zone. the panels in network having true peer to peer provision. the panel shall have provision to support up to 50 releasing zones to protect against 50 independent hazards.the panel should be equipped with sufficient numbers of loops considering 20% spare capacity in each loop and shall be extendable upto 10 loops. , supplying , installing , testing and commissioning approved make modbus interface gateway for communication with bms / other utilities. modbus shall support supports reads of up to 100 registers at a time. modbus gateway shall act as an independent node communicating on the peer to peer network and shall not be dependent on the fire panel cpu for operation. modbus over tcp/ip , meets ul 864 , 10th edition requirements , supports two modbus masters & monitored 10 cpu nodes . failure of fire panel cpu shall not result in failure of modbus gateway. the gateway card shall be ul listed , the mimic annunciator for the fire alarm control panels (facp). this provides the facp with remote , serially-connected display. a five inch touchscreen display provides system status , point information , and event counters. the display shows two events simultaneously , and pages through up to 50 of the highest priority events in the system. the remote display also provides system control with six programmable softtouch buttons as well as acknowledge , silence , reset and drill. , supplying , installing , testing and commissioning approved make addressable multi-criteria photo-thermal detector with sensitivity range of 0.5 to 4.0% obs/ft.the intelligent multi criteria detection device shall include the ability to combine the signal of the thermal sensor with the signal of the photoelectric signal in an effort to react hastily in the event of a fire situation. it shall also include the inherent ability to distinguish between a fire condition and a false alarm condition by examining the characteristics of the thermal and smoke sensing chambers and comparing them to a database of actual fire and deceptive phenomena. the detector shall have twin bi-colour led for 360 deg viewing. addressing shall be with user friendly rotary decimal switches. detectors having base addressing must provide protective cap. detectors with soft addressing must provide programming tool. the detector sensitivity (day & night) shall be controlled from the panel to get accustomed to the local environment. the detector shall be ul listed & fm approved. , supply , installation , testing and commissioning addressable self-test multi-criteria photo-thermal detector with sensitivity range of 0.5 %/ft to 4.0 %/ft obs. intelligent multi criteria detection device shall include the ability to combine signal of the thermal sensor with photoelectric signal in an effort to react hastily in the event of a fire situation. , supplying , installing , testing and commissioning approved make addressable manual call point ( break glass type). the device shall have an led which shall blink in normal state & get steady on activation to monitor the heath status of the device. the device shall be ul listed & fm approved. , supplying , installing , testing and commi
Tender For auction sale of rolling stock - condemned bg 8 wheeler accident involved lhb power car ( luggage brake cum generator car) with all available ferrous-non ferrous-wooden fittings thereon excluding rc items . mechanical rc items: 1) complete fiat bogie arrangement complete set, 2) wheel set complete with axle and roller bearing assembly complete set, 3) centre buffer coupler complete set, 4) main door, 5) lavatory door, 6)ic door. electrical rc items: 1) rmpu unit complete set, 2) 60kva transformer, 3) rebc cum rbc, 4) d&ed (disconnecting and earthing device), 5) contactors, 6) microprocessor and display, 7) smoke detection and sensor.coach number- 1) ec lwlrrm 181371 c = 1 coach, ds8 no: 023280-25-11875 dt 24.10.2025 (232820 dt 24.10.2025) , pl.no. 98111061, location: near kavarapettai railway station, custodian: sse/c&w/tnpm, note: 1) at the time of delivery all items including zero value items such as rexene, rubber, frp etc., should be removed and cleared by the purchaser from railway premises and should be disposed as per the existing norms of central/state government.d and cleared by the purchaser from railway premises and should be disposed as per the existing norms of central/state government. 2) bio toilet to be defaced before delivery. 3)rate per number should be quoted,4)coaches are accident involved and grounded/trapped/upside down condition .5) all rc items which are in cut/damaged condition are not saleable and should be handed over to custodian only. 6) nitrogen cylinders, water cylinders, fire extinguishers available in the coach are not saleable and should be handed over back to custodian. 7) rc items to be handed over to the custodian at specified location (8) cutting permitted to loadable size only. (9) crane loading permitted. (10) purchaser should take safety precaution while cutting of coach.(11) one fuel tank available in power car and another is available between the main tracks which is away from power car, both are saleable. (12) the purchaser may be permitted to remove the saleable items from the power car without disturbing the brake van, which is very close to the power car due to the accident.
Tender For corrigendum : tender for supply of tp mccb rated 630a , tp mccb rated 100a , double pole on-off rotary switch rated 16a , 24 way spt with headset socket and amplifier , contactor 110a t.p.(contact kit) , frequency meter 55-60-65hz 440v , size 96x96mm rm at 60hz , single ph transformer440/415/380v to230/220/24v , 200va50/60hz , d w transformer class f insulation380 127v , 300va 1ph , 50hz , single ph double wound transformer 415/230/24v , 50hz , 300va , smoke detector tester gas bottle - solo , cable 3x1.5 sq. mm , battery for obd , fuse 15a fitting for hrc , mcb6a , magnetic float sensor , daq control module , daq (a) c131eth(3).ibil24di/32/hd-pac(07) ibila18/sf-pac(03) , obd hanging head unit , clip on type terminals 6sq.mm (ts 6) , clip on bus type terminals 50sq.mm , auto changeover card , auto transfer switch 50/100 a
Tender For supply of replacement of defective or senseless with compatible multi sensor smoke detector , xipe cross linked polythene thermostatic cable cable multi core , laying charges for cable including fire proof pipe , compatible addressable manual call point , compatible addressable sounder and strobe , online power backup source 1000va 60min 4 no 62 ah battery , addressable panel external surge supply with spd integration including 0.2 ohm rapid release surge cancellation device including wiring , installation and configuration , fire bell with manual call point including installation and electrical socket with wiring , annual maintenance contract for existing infrastructure of afds for 03 panel and allied equipment