Tender For repair & maintenance infrastructure assets during the year 2024-25.sub-head: procurement of various size of lt heat shrinkable st. through joint box for provide perfect joining functions and protection from short circuit in lt cables, under road light division, new delhi."
Tender For special repair replacement of lt xlpe cable pole box assembly bus bar chamber led street light fittings and connected items at mall road polo road cassel road and mandir marg area of age sldc under ge u es delhi cantt 10
Tender For repair/replacement of lt ug cable, lt poles, control panels board, change over switches and allied items at af station naliya under ge(af) naliya - taking out old unserviceable lt cable of any size any type from trench/duct/ poles / roof/pipe etc and keeping aside for segregation of serviceability. serviceable cable will be re-laid at same place or other place as required complete all as specified and directed., supply, laying and connecting xlpe insulated, armoured, heavy duty electric cable multi stranded aluminum conductors, 1100v grade, of size 06 sqmm 2core with proper size of lugs and laid in trenches / ducts / through gi pipe / fixed to poles etc complete all as specified and directed. note: excavation earthwork, cable covers, sand cushioning and gi protection pipe shall be measured and paid separately under relevant item., all as per serial item number 2.00 here-in-before but of size 16 sqmm 4 core., all as per serial item number 2.00 here-in-before but of size 35 sqmm 3.5 core, all as per serial item number 2.00 here-in-before but of size 50 sqmm 3.5 core, all as per serial item number 2.00 here-in-before but of size 70 sqmm 3.5 core, all as per serial item number 2.00 here-in-before but of size 95 sqmm 3.5 core, re-laying of old serviceable cable of any size obtained from item above. note:- excavation earthwork, cable covers, sand cushioning and gi protection pipe shall be measured and paid separately under relevant item., excavation in trenches not exceeding 1.5 metre wide and not exceeding 1.5 metre in depth and getting out in soft/ loose soil, for laying of under ground electric cable, pipes etc complete all as specified and directed. note:-(i) authorised width & depth shall only be excavated, measured and paid as specified in clause 3.2.3 of ssr part ii and 19.74.1 of ssr part i for cable/pipe laying portion.(ii) serviceable pcc /rcc cable cover obtained during excavation shall be stacked separately carefully without any extra cost to the deptt., material and labour for river bed sand filling in trenches/ ducts 15 cm above cable and 8 cm under the cable for cushioning/protection to cable including spreading, leveling and get thick 18cm after hand punning complete all as specified and directed, laying only serviceable un-reinforced precast concrete cable cover class lv, type 1, flat, of 250 mm x 150 mm x 40 mm obtained from trenches, abetting each other with gap between adjacent slab not exceeding 10 mm over under cable for protection complete all as specified and as directed., supply and laying un-reinforced precast concrete cable cover, class lv, type 1, flat, size 250 mm x 150 mm x 40 mm abetting each other with gap between adjacent slab not exceeding 10mm over under cable for protection complete all as specified and as directed., returning, filling in, including spreading, leveling, watering and well ramming in layer not exceeding 25cm thick each complete all as specified and directed., removing excavated soil to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.50 metre above the starting point complete all as specified and directed., material and labour for cutting under the road /pavement /hard standing or in any other situation with the manual labour for crossing of u/g cable through it and making both the end good complete all as specified and directed ., supply and laying gi water tubing of 80 mm bore, light grade, is-1239 marked with all fittings is marked and laid in trenches/under roads/in drains with suitable size flat iron/gi clamps, bolts, nuts and washers etc for cable protection complete all as specified and directed., supply and laying gi water tubing of 50 mm bore, light grade, is-1239 marked with all fittings is marked and laid in trenches under roads/in drains, fixed to poles/walls with suitable size flat iron/gi clamps, bolts, nuts and washers etc for cable protection, complete all as specified and directed ., supply and laying gi water tubing of
Tender For repair/ replacement of lt underground cables and connected items in various locations at mil stn yol - excavation in trenches, not exceeding 1.5 mtr wide and not exceeding 1.5 mtr in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. not exceeding 10 sqm on plan and not exceeding 1.5 mtr in depth and getting out in hard dense soil, complete all as specified and directed., excavation in trenches, not exceeding 1.5 mtr wide and exceeding 1.5 mtr but not exceeding 3 metre in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. not exceeding 10 sqm on plan and not exceeding 1.5 mtr in depth and getting out in hard dense soil, complete all as specified and directed., returning filling in (soil) including spreading, levelling, watering and well ramming in layers n.exc 25cms thick in any type of soil complete all as specified and directed., removing excavated materials/ soils, not exceeding 50mtrs and depositing where directed at a level not exceeding 1.50mtrs, complete all as specified and directed., pcc 1:3:6 (nominal mix) type c-2 (using 40mm graded crushed stone aggregates) as in coping of pole including necessary form work complete all as specified and directed., pcc 1:4:8 (nominal mix) type d-2 (using 40mm graded crushed stone aggregates) as in foundation filling and mass concrete complete all as specified and directed., sand cushioning to protection of underground cables, laid 8 cm before laying and 15 cm after laying of cable, and punned to form an overall layer of 18 cms thick, complete all as specified and directed note: punned thickness shall be measured., sub class b brick, old size, brick covering laid dry, flat, transversally along the length of cable on sand cushioning, with width equal to the length of the brick including taking out old bricks, complete all as specified and directed., laying only bricks along the length of cable on sand cushioning, with width equal to the length of the brick , complete all as specified and directed., mild steel galvanised iron tubing light grade for cable protection as in road crossing, along poles, walls, floors, drain of 80mm size fixed with ms clamps, nuts and bolts required complete all as specified and directed., mild steel galvanised iron tubing light grade for cable protection as in road crossing, along poles, walls, floors, drain of 50mm size fixed with ms clamps, nuts and bolts required complete all as specified and directed., dismantling poles/struts, any size and type including insulators and removing from site, complete all as specified., supply, jointing, fixing or passing through pipe , trenches or ducts, commissioning and testing xlpe insulated screened and pvc sheathed armoured electric power lt cable heavy duty with aluminium conductor nominal cross sectional area 300 sqmm 3.5 core for working voltage upto including 1100 volts conforming to is-7098 (part-i) 1988 including taking out existing unserviceable cable, complete all as specified and as directed., supply, jointing, fixing or passing through pipe , trenches or ducts, commissioning and testing xlpe insulated screened and pvc sheathed armoured electric power lt cable heavy duty with aluminium conductor nominal cross sectional area 240 sqmm 3.5 core for working voltage upto including 1100 volts conforming to is-7098 (part-i) 1988 including taking out existing unserviceable cable, complete all as specified and as directed., supply, jointing, fixing or passing through pipe , trenches or ducts, commissioning and testing xlpe insulated screened and pvc sheathed armoured electric power lt cable heavy duty with aluminium conductor nominal cross sectional area 185 sqmm 3.5 core for working voltage upto including 1100 volts conforming to is-7098 (part-i) 1988 including taking out existing unserviceable cable, complete all as specified and as directed., supply, jointing, fixing or passing through pipe , trenches or ducts, commissioning and testing xlpe i
Tender For special repair replacement of lt xlpe underground cables pole box assembly bus bar chamber led street light fittings and connected items at maude road poultry farm no 04 and acms hostel area age u sldc under ge u elect supply delhi cantt 10
Tender For construction of 7no covered shed, cement concrete road and parking repair, high mask light and street light, main gate, check post, cow catcher, boom barrier, cctv, weigh bridge, general toilet, water supply, stamped concrete flooring on existing covered shed and open platform, bitumen on existing cement concrete road parking and cement concrete work, bank building, covering open platform and vermi compost tank at new mandi yard patelpali in mandi samiti raigarh distt-raigarh