Get complete information related to latest Semiconductors Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Semiconductors Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Semiconductors Tenders.
Tender For supply of electrical items - s.no items unit qty. 1 supply of 240/415 v ac mcb with positive isolation of 10 ka breaking capacity (b/ c/d tripping characteristic as per type of load and site requirement) 4 kv impulse withstand voltage, isi marked is 8828(1996) / conforming to iec 60898-1 2002, iec 60947-2, low watt losses, trip free mechanisum , energy limiting of class 3 as per iec, minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , ip 20 contact protection and fitted in existing distribution board/sheets, minimum electrical operation 20,000 upto 20 a rating and 10,000 upto 63 a, 5000 for 80 a & above rating. single pole mcb 10a rating. each 100.0 2 supply of 240/415 v ac mcb with positive isolation of 10 ka breaking capacity (b/ c/d tripping characteristic as per type of load and site requirement) 4 kv impulse withstand voltage, isi marked is 8828(1996) / conforming to iec 60898-1 2002, iec 60947-2, low watt losses, trip free mechanisum , energy limiting of class 3 as per iec, minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , ip 20 contact protection and fitted in existing distribution board/sheets, minimum electrical operation 20,000 upto 20 a rating and 10,000 upto 63 a, 5000 for 80 a & above rating. single pole mcb 16a rating. each 100.0 3 supply of 240/415 v ac mcb with positive isolation of 10 ka breaking capacity (b/ c/d tripping characteristic as per type of load and site requirement) 4 kv impulse withstand voltage, isi marked is 8828(1996) / conforming to iec 60898-1 2002, iec 60947-2, low watt losses, trip free mechanisum , energy limiting of class 3 as per iec, minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , ip 20 contact protection and fitted in existing distribution board/sheets, minimum electrical operation 20,000 upto 20 a rating and 10,000 upto 63 a, 5000 for 80 a & above rating. single pole mcb 25a rating. each 70.0 4 supply of 240/415 v ac mcb with positive isolation of 10 ka breaking capacity (b/ c/d tripping characteristic as per type of load and site requirement) 4 kv impulse withstand voltage, isi marked is 8828(1996) / conforming to iec 60898-1 2002, iec 60947-2, low watt losses, trip free mechanisum , energy limiting of class 3 as per iec, minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , ip 20 contact protection and fitted in existing distribution board/sheets, minimum electrical operation 20,000 upto 20 a rating and 10,000 upto 63 a, 5000 for 80 a & above rating. single pole mcb 32a rating. each 70.0 5 supply of 240/415 v ac mcb with positive isolation of 10 ka breaking capacity (b/ c/d tripping characteristic as per type of load and site requirement) 4 kv impulse withstand voltage, isi marked is 8828(1996) / conforming to iec 60898-1 2002, iec 60947-2, low watt losses, trip free mechanisum , energy limiting of class 3 as per iec, minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , ip 20 contact protection and fitted in existing distribution board/sheets, minimum electrical operation 20,000 upto 20 a rating and 10,000 upto 63 a, 5000 for 80 a & above rating. single pole mcb 40a rating. each 50.0 6 supply of 240/415 v ac mcb with positive isolation of 10 ka breaking capacity (b/ c/d tripping characteristic as per type of load and site requirement) 4 kv impulse withstand voltage, isi marked is 8828(1996) / conforming to iec 60898-1 2002, iec 60947-2, low watt losses, trip free mechanisum , energy limiting of class 3 as per iec, minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , ip 20 contact protection and fitted in existing distribution board/sheets, minimum electrical operation 20,000 upto 20 a rating and 10,000 upto 63 a, 5000 for 80 a & above rating. double pole mcb 10a rating each 20.0 7 supply of 240/415 v ac mcb with positive isolation of 10 ka breaking capacity (b/ c
Tender For supply of kapton covered copper conductor, dimension of bare copper 6.90 +/- 0.07 mm x 3.30 +/- 0.05 mm and corner radious 0.8 +/- 0.1 mm. dimension over 2/3 positive lap (67 to 70%), insulati on 7.26 x 3.63 mm max. as per clw's spec. no. - 4tms.095.002 (rev. 0) of dated - 23.06.2011 for po wer coil of hitachi tr. motor armature. [ warranty period: 30 months after the date of delivery ]