Get complete information related to latest Serology Test Kit Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Serology Test Kit Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Serology Test Kit Tenders.
Tender For tender for supply of pt reagents , hiv rapid test 4th gen , hcv rapid testkit , hbsag rapid testkit , aso rapid kit , ra factor manual latex testkit , aptt reagent , plastic cuvette for stago coagulometer pack of 1000 , leishman stain for hematological staining with buffer powder , glass slide size 76.2 x 25.4 mm thickness 1mm x 1.2mm pack of 50 , ceder wood oil , dengue ns1 , igg , igm combo rapit kit , hrp2 rapid kit for p falciparum and p vivex , disposable tissue processor cassetes , ethanol ethyl alcohol contain 99.9 percent ethanol for histopathological tissue processing , paper filter 51x51cm , paraffin wax for histopathological tissue processing melting point 55 degree to 60 degree c , glass cover slip size 22x50mm thickness no 0.13 to 0.16mm small pack of 20 each 10 gm , glass cover slip size 22x40mm thickness no 013 to 0.16 mm small pack of 20 each 10 gm , xylene xtra pure bott of 500 ml , uristics protein plus glucose bott of 100 , uristics protein plus ketone bott of 100 , haemospot kit for occult blood rapid test , petri dish glass borosil 90 mm diameter , sterilised flexible loop 0.4 mm diameter calibrated to 0.01 ml individually seated hi flexi loop , 1000ul medical grade virgin polypropylene universal pipette tips sterile racked pack of 96 , micropipettes tips for 1 to 200 ul unsterile , 200 ul medical grade virgin polypropylene universal pipette tips sterile racked , pulv glucose for oral use pack of 75 gms , uristics urine dipstick multistick siemens , glycerine glycerol bott of 500 ml , harris haematoxylin 1a for histopathological and cytological staining , leica 819 low profile blade for leica microtome , sheep blood agar ready to use sterile plate , chocolat agar ready to use sterile plate , macconky agar ready to use sterile plates with 0.15percent bile salt crystal violet ana nacl , cled agar ready to use sterile plate with bromothymol blue , potato dextrose agar plate with tetracycline and chloraphenical , sabouraud chloraphenical agar plate , mini cube esr chips , assayed chemistry control level1 , assayed chemistry control level2 , lyphocheck diabetes control bi level 3 of each level , haematology trilevel controls , torniquete , hydrochloric acid , glucose broth ready to use in tubes code lq010v , typhidot immunochromatographic assay for qualitative and differential detection of salmpnella typhi igm and igg antibodies , syphillis rapid kit , sterile cotton swab in screw capped polypropylene tube cotton bud with polypropylene stick individually packed , ferric ammonium alum , picric acid , chromic acid , methanamine , sodium thyosulphate , potassium metabisulphate , borax , potassium permagnate , bouins fluid , periodic acid pack of 100gm , light green powder , pa coliform kit water bacteriologcal test , leptospira rapid testkit , scrub typhus rapid testkit , silver nitrate pack of 10gm
Tender For e-tenders are invited from the manufacturers for the two year rate contract cum supply of haemodialysis disposables and consumables items, crrt and peritoneal dialysis relateditems for institute of kidney disease and research centre (ikdrc), ahmedabad. - paediatric dialyzer (low/middle flux) 0.5m to 0.7m, dialyzer (low/middle flux) 1.0m to 1.1m, dialyzer (low/middle flux) 1.3m to 1.4m, dialyzer (low/middle flux) 1.7m to 1.8m, dialyzer (high flux) 1.7m to 1.8m, av bloodline set post pump-hd machine (adult), av bloodline set post pump-hd machine (paediatric), avf needle (16g/17g), acid concentration part a, acid concentration part a (with dextrose), acid concentration part a (k+ free), dry bicarbonate concentrate powder cartridge (650gm)for fresenius hd machine, dry bicarbonate concentrate powder cartridge (650gm) for nipro hd machine, hot disinfectant for h.d / hdf machine / water treatment system, cold disinfectant for h.d / hdf machine / water treatment system, disposable syringe 20ml sterilized w/o needle (virgin material), disposable syringe 10 ml sterilized w/o needle (virgin material), infusion set (iv set) with needle, latex medical examination gloves (non-sterile)(extra small/small/medium/large/extra large), r-hu erythropoietin 2000 iu injection pfs, r-hu erythropoietin 4000 iu injection pfs, r-hu erythropoietin 10000 iu injection pfs, heparin sodium 25000 iu / 5 ml injection, heparin sodium 5000 iu / 5 ml injection, multivitamin injection (2 ml to 5 ml), levocarnitine 1 gm/5 ml injection, sodium chloride 0.9percent w/v i.p. 1000 ml injection, sodium chloride 0.9percent w/v i.p. 500 ml injection, sodium chloride 0.9percent w/v i.p. 100 ml injection, dextrose 25percent w/v i.p.100 ml injection, haemodialysis on-off kit for dialysis procedure convenience, paper surgical adhesive tape roll (width-1 inch), transparent film dressing - 10cm x 12cm, transparent film with chg gel dressing - 8cm x 12cm (adult), transparent film with chg dressing - 7cm x 8.5cm (paediatric), double lumen dialysis catheter 11.5-12 fr. x 13-13.5 cm curved extension, double lumen dialysis catheter 11.5-12 fr. x 13-13.5 cm straight extension, double lumen dialysis catheter 11.5-12 fr. x 15-16 cm curved extension, double lumen dialysis catheter 11.5-12 fr. x 15-16 cm straight extension, double lumen dialysis catheter 11.5-12 fr. x 19-20 cm straight extension, double lumen dialysis catheter 10 fr. x 10 cm straight/curved extension, double lumen dialysis catheter 8-8.5 fr. x 9-12 cm straight/curved extension, double lumen dialysis catheter 6.5 fr. x 8 cm straight/curved extension
Tender For corrigendum : procurement of disposable and implants items for ctvs department rgssh - part-01, oxygenator membrane (adult) with hard shell reservoir:1. should have a micro porous hollow fibre membrane oxygenator2. should have open circuit configuration3. should have hard shell venous reservoir of capacity more than 4000ml. with built of cardiotomy reservoir with 30 filter capacity.4. should have blood flow range 0.5 ltr to 7 ltr/min.5. should have priming volume less than 220ml6. should have high efficiency heat exchanger.7. venous return port with rotating facility.8. should have an auto vent facility.9. port size : arterial outlet, venous outlet 3/8 venous inlet 10. should have sampling port., oxygenator membrane (semi-adult) with hard shell reservoir:1. should have a micro porous hollow fiber membrane oxygenator2. should have open circuit configuration3. should have hard shell venous reservoir of capacity more than 3000ml. with built of cardiotomy reservoir with 30 filter capacity.4. should have blood flow range 0.5 ltr to 3.5 ltr/min.5. should have priming volume less than 180ml6. should have high efficiency heat exchanger7. venous return port 3/8 with rotating facility.8. should have an auto vent facility.9. port size : arterial outlet, venous outlet 3/8 venous inlet 3/8 10. should have sampling port., oxygenator membrane (paed.) with hard shell reservoir:1. should have a microporus hollow fiber membrane oxygenator2. should have open circuit configuration3. should have hard shell venous reservoir of capacity more than 1000ml. with built of cardiotomy reservoir with 30 filter capacity.4. should have blood flow upto 2.8 ltr/min.5. should have priming volume less than 140ml6. should have high efficiency heat exchanger.7. venous return port 3/8 with rotating facility and redurs8. should have an auto vent facility.9. port size : arterial outlet 1/4 , venous inlet 3/8 with redurs, oxygenator membrane (neonatal):1. should have venous inlet .2. arterial outlet port tubing size.3. it should have least priming volume less than 70ml.4. arterial flow upto 1.2 ltr/minute.5. approximate reservoir capacity should not be 600ml.6. should have redurs.7. blood inlet and outlet port size redu able to 3/16 ., pre-connected tubing pack adult with arterial line filter:1. circuit diagram attached.2. tubing should have transparent, medical implant grade pvc of class vi usp, marked., pre-connected tubing pack paed. with arterial line filter:1. circuit diagram attached2. tubing should have transparent ,medical implant grade pvc of class vi usp, marked, pre-connected tubing pack paediatric small. with arterial line filter:1. circuit diagram attached2. tubing should have transparent ,medical implant grade pvc of class vi usp, marked, pre-connected tubing pack neonatal. with arterial line filter:1. circuit diagram attached.2. it should have a good quality arterial filter pore size should have 35-40 micron.3. tubing should have transparent medical implant grade pvc of class vi usp, marked., online blood cardioplegia delivery system:1. should have in built high efficiency heat exchanger of metallic for fast cooling & re- warming.2. should have priming volume less than 80ml.3. should have max flow rate 1 ltr/min4. should have pressure drop not more than 13mmhg 500ml/min5. should have blood to crystalloid ratio of 4:1 with bride connection facilities and interchangeable tubing ratio.6. should have auto-vent line system on accidental bock of cardioplegia deliver liner.7. pvc tubing should have medical implant grade of class vi ,usp, marked., ante- grade root cardioplegia cannula with side arm:1. should have size 12fr,14 fr. & 16 fr.2. should have regular tip stilate with side arm for vent with flange3. selection strictly on quality basis., ante- grade root cardioplegia cannula without side arm:1. should have size 12fr, 14 fr. & 16 fr.2. should have regular tip stilate with flange3. selection strictly on quality basis.4. iso certification, coro