Tender For corrigendum : tender for supply of manual call point with inbuilt sci for wet space ip67 , ev p analog addresable optical smoke detector dry space ip22 , universal base , base plate , spb adapt base , charger m h , changeover mx h , relay m 8 h , electronic siren 24vdc ip66 red , manual call point with inbuilt sci for dry space ip23 , mcp a adressable manual call point for dry space ip 23 , testifire multi detector tester , short circuit isolator for wet space ip 67 , short circuit isolator for addr loop unit for wet space ip67 , ns adapt bs plate
Tender For corrigendum : ca no ge(w)/hsr-61/2025-26 repair / maint of mech laundry system fire fighting heat and smokedetectionsystem eot over head cranes and lifts incl certain allied works at hisar military station under ge (w) hisar
Tender For bid to ras corrigendum : supply of data center infrastructure management solution , aspirating smokedetectionsystem vesda , ip based cctv surveillance system , 32 inch monitor for cctv surveillance system , air purification system for server room , intelligent power distribution units for server racks , cold aisle containment system for server farm area , water leak detection wld system , rodent repellent system for dc , power cords , installation, implementation, integration, testing, migration, commissioning , post warranty comprehensive amc of supplied data center infrastructure management solution , post warranty comprehensive amc of supplied aspirating smokedetectionsystem vesda , post warranty comprehensive amc of supplied ip based cctv surveillance system , post warranty comprehensive amc of supplied 32 inch monitor for cctv surveillance system , post warranty comprehensive amc of supplied air purification system for server room , post warranty comprehensive amc of supplied intelligent power distribution units for server racks , post warranty comprehensive amc of supplied cold aisle containment system for server farm area , post warranty comprehensive amc of supplied water leak detection wld , post warranty comprehensive amc of supplied rodent repellent system for dc
Tender For corrigendum : tender for supply of additional items of ipms for pcv 1267 1268 : : -deck head mounting box part no - 45681-217apo (for yard 1267) , deck head mounting box part no - 45681-217apo (for yard 1268) , deck head mounting base part no - 45681-210mar (for yard 1267) , deck head mounting base part no - 45681-210mar (for yard 1268) , optical smoke detector part no - 58000-600mar (for yard 1267) , optical smoke detector part no - 58000-600mar (for yard 1268) , bilge or flood sensors (for yard 1267) , bilge or flood sensors (for yard 1268)
Tender For corrigendum : supply & installation of combined aspiration type automatic fire & smokedetectionsystem integrated with linear heat detection (lhd) cable system.
Tender For corrigendum : revamping and expansion of existing smokedetectionsystem at ongc uran plant and ongc trombay terminal with five years post warranty comprehensive annual maintenance contract
Tender For supply of refurbishment of room flooding system of server room at sauw ins satavahana c c -refilling of hfc 227ea gas 1,1,1,2,3,3,3 hepta fluro propane, zero odp, stored pressure, gas , conventional gas release panel with battery backup and cross zoning facility 2-zone with fire ext automatic mini intuitive fk-5-1-2 300gm ss sp red 79 c with nrv , ms container strap for mounting and fixing the agent containers to the wall , ul container strap for mounting and fixing the agent container to the wall , valve assembly and arrangement for supervisory switch connection for monitoring cylinder pressure, a pressure gauge with a safety burst disc and a safety cap 25 bar , pressure gauge cum switch for monitoring the cylinder pressure 0-60 bar, 22. 50 bar switch point pressure switch wasco switch point 5bar 72. 5 psig imp with fire ext automatic wm fk 5-1-12 4kg , hydro static pressure test 50 bar, inverted baker test, helium leak detection test, epoxy powder painting, dismantling, commissioning charges , conventional optical smoke detector with double dust trap chamber design, optimized performance using internal algorithm, central led for 360 status visibility, compiles to en 54-7 standard , conventional rate of rise heat detector, heat alarm threshold temperature 58 c central led for 360 status visibility, complies to en 54-7 standard and approved by lpcb, vds , installation and delivery charges
Tender For supply of spares for fire alarm system d d - conventional manual call point make apollo fire detectors ltd model orbis part no 55100 031 apo , conventional multi sensor with base make apollo fire detectors ltd model orbis part no orb oh 13003 apo , conventional heat detector with base make apollo fire detectors ltd model orbis part no orb ht 11013 apo , conventional optical smoke detector with base make apollo fire detectors ltd model orbis part no orb op 12003 apo , intelligent input output module make apollo fire detectors ltd part no sa4700 102apo , addressable manual call point make apollo fire detectors ltd part no sa5900 908apo , addressable sounders make apollo fire detectors ltd part no 55000 001apo , addressable multi sensor with base make apollo fire detectors ltd model soteria part no sa5100 700apo , addressable heat detector with base make apollo fire detectors ltd model soteria part no sa5100 400apo , optical smoke detector with base make apollo fire detectors ltd model soteria part no sa5100 600apo