Tender For following works shall be carried out quarterly during the contract period for the two identical sets of co2 flooding system at mghe power house. the one set of system for carting to the units-1,2,3&4 and the second set of system for carting to units-5,6,7&8. i)cleaning of heat detector externaly with dry cloth ii)ensure working condition of heat detectors iii)cleaning of smoke detector externaly with dry cloth iv)ensure working condition of smoke detectors v)simulate heat and smoke detector simultaneously and check for cross zone vi)checking for leakage in pilot cylinder vii)checking the weight of co2 pilot cylindersviii)check the condition of co2 pilot hose ix)check the condition of co2 discharge hose x)inspect pressure switch and check for its functioning xi)inspect maual call points and check for its functioning xii)inspect abort switch and check for its functioning xiii)inspection of online weigh monitor and check for its functioning xiv)inspect hooter with strobe and check for its functioning xv)checking for healthiness of the battery xvi)checking the condition for slave nrv xviichecking the condition for master nrv xviii)checking of solenoids. xix)refilling of co2 cylinder and pressure testing 45 kg capacity and 4.5kg capacity (in case release of co2 gas during generator fire incidents) xx)any other work connected with the system not explicitly mentioned shall also be carried out for safe and proper operation of the system. xxi)conducting the demo of operation of the co2 flooding system twice (once in 2 quarter) during the annual maintenance contract period for kpcl staff.
Tender For ghrssidc/e-t/2026-27/731 - dismantling the tile work in floors and roofs laid in cement including stacking of materials within 50 meters lead for thickness of tiles 10mm to 25mm., dismantling cement asbestos celotex or other ceiling or partition hard broad wall including stacking of serviceable materials and disposal of unserviceable materials within 50 mts. lead., dismantling doors, windows and clearestory windows (steel or wood) shutters including chowkhats architrave holdfast etc. complete and staking within 50 mt. leada.of area 3 sq.m. and below, clearing debris includes civil/elect items from site and disposing the debris 10km away from the site including loading unloading labour charges and clearing the site good for work etc.complete, providing and fixing of double leaf door with cnc cutting as per design made in -20mm plywood with 3mm thick veneer using ss pvd coated t patties and pu paint and melamine polish using ply of century or equivalent brand including all necessary hettic soft closing fittings etc. complete, providing and fixing of single leaf door made in -12mm plywood with 3mm thick veneer using ss pvd coated t patties and pu paint and melamine polish using ply of century or equivalent brand including all necessary fittings etc. complete, providing and fixing of partition board paneling with aluminium frame work of section size 50mmx25mm vertically and horizontally at 600mm c/c with 12mm thick plywood, top with 3mm thick veneer sheet and using ss pvd coated t patties and pu paint and melamine polish for smooth finish, using century ply or equivalent brand for panelling and fixing with necessary screwing and supports etc.complete, supplying of fire sensor / smoke detector-10nos / existing sprinker replacement / relocation / wiring / hooter panel etc, providing and fixing vitrified double glazed finished of 10mm thick tiles of size 8ft x 4ft in floor, treads or riser of steps, landing on 25mm thick bed of cement mortar 1:3 and jointed with cement slurry filling tile joints with matching pigment and make of of kajariya/ simpolo of any colour as specfied by engineer in charge etc.complete., proving and fixing false ceiling of 1.5mm thick aluminium powder / anodised / painted / coated -profiled panels mounted on ms/ gi frames for support and painted / powder coated chanels / with provision for ac trap, door and light fixing,as per engineer incharge etc.complete, providing and laying in position (1:11/2:3) reinforced cement conrete excluding the cost of centering, shuttering, finishing and reinfrocement (1 cement: 1 coarse sand:3 graded stone agg 20mm nominal size) c. in beams, suspended floors, roofs having slope upto 15 landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases upto floor five level, supplying and fixing of window / roller blind made in100% polyster fabric design plain and colour as per engineer in charge, providing and fixing of 3+2+1+1 seater sofa set made in sal wood frame with high density foam as design as per drawing and engineer in charge, supplying and fixing of designer artifacts showpiece design as per drawing and engineer in charge, supplying and fixing of nylon based carpet 5 mm thickness with backing design as per drawing and engineer in charge, supply and placing in position artificial planters with ceramic pots etc complete as shown in the drawing and as directed engineer incharge., design & supply of signages made from 2mm thick external grade acp sheet of size (wall mounted) with high grade plotter-cut/cnc-cut vinyl & auto-glow vinyl pasted lacquering of letters/pictogram on front side of the plate, of varying colours as per detail drawing and engineer in charge., supplying and fixing of pa - speaker wiring with 6nos ceiling mount speaker to be connected to existing pa system including cabling ,fittings accessceries and necessary supports etc complete., supplying and fixing of light fittings of make -hybac /haffle /phillips / panasonic/ anchor/
Tender For corrigendum : supply of fire detection and alarm system powergrid silchar sub station : : - smokedetectionsystem , fire detection and alarm system for control room , fire detection and alarm system for switchyard panel room of 9 m length , fire detection and alarm system for 400kv gis hall , fire protection system for local relay room for gis , indoor fire detection and alarm system for fire fighting pump
Tender For supply of hot wire testing equipment with analog meter specification - i/p voltage 220/240 volt, o/p voltage - 6 volt 30 amp for diagnosing the automatic fire and smokedetectionsystem as per str rdso/2008/cg-04 (rev. 6) [ warranty period: 30 months after the date of delivery ] ]
Tender For supply of set of smoke detector and fire alarm system for memu motor coaches conforming to rcf specification no edts-087 rev-b with corrigdenum-1 or latest. set consists of 03 items 1)-control unit 01 no. 2)-detector head 1set (2nos). 3)- alarm unit 01 no. accepted make: integ,kaamney,agni or equivalent [ warranty period: 30 months after the date of delivery ] ]
Tender For supply of smoke detector and fire alarm system conforming to rcf specification no. edts-087, rev.-'b' with corrigendum-1 &2 . [ warranty period: 30 months after the date of delivery ][quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitted: max 8 lacs ] ]
Tender For tender for supply of fire detection and annunciation system - m call pt for indoor , m call pt for outdoor , multicriteria type smoke detectors , inteligent adrsable control oi3 module , zone ctrl card , mdl 600mw , intelligent addrsable zoneaim module , probe type heat detector , response indicator , loop hooter of fda system , display card of fda system , mcu card of fda system , ofc netwok card of fda system , loop card 600 mw , psu 6 pwr supply mod for fire alarm , listec controller of fda system , listec connnection box of fda system , listec connecting cable of fda system
Tender For comprehensive annual maintenance work for two years of the fire/smoke detector and related system installed in the building, along with hydrostatic testing of 04 fm-200 cylinders and refilling with hfc-227ea clean agent gas, and supply and installation of 02 additional fm-200 cylinder banks at u p sldc limited bhawan, gomti nagar, lucknow under se (estt.& hr), u p sldc limited, lucknow