Web Analytics Made Easy - StatCounter

Sound Proof System Tenders

Get complete information related to latest Sound Proof System Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Sound Proof System Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Sound Proof System Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

CTN :42922643 Due date: 10 Dec, 202510 Dec, 2025 NA
Tender For purchase of equipments - purchase of equipment:chromatographic workstation with capillary injector, packed injector, and auto-sampler should be quoted. chromatography workstation instruments should be built with self-diagnostic features and active-time management tools for better productivity, general features of chromatography workstation: column oven can accommodate two columns with maximum temperature range up to 400 c with set point resolution of 0.1 c. it should support 20 ramps & maximum temperature ramp rates of 100 c /min. cool down of oven from 400 c to 50 c in less than 5 min. fully automated with electronic pneumatic control afc / ppc / epc (digital control) for injector gas afc/epc/ppc should provide optimum performance with all types of capillary columns. system should have the capability to install a minimum of three injection and four detector ports. capable of detecting h and o across 0.01% 100% ranges (i.e., both trace in a matrix and bulk near-pure streams) column oven: operational temperature range: ambient +10 to 400 c overheat protection: programmable up to 420 c injector port: split/spitless injector 1 no packed injector 1 no, maximum temperature: 400 c, pressure setting range 0 100 psi with control setpoint of 0.01psi for specified pressure range., carrier gas flow control should have constant flow, constant pressure modes and constant linear velocity. auto injector: automatic sample injector up to 15 vials 2 ml vial with crimp set 100 nos, detector: flame ionisation detector (fid) 1 no, minimum detectable quantity: 3 pgc/s or more liner dynamic range: 1 107, maximum acquisition rate: 4 ms (250hz), thermal conductivity detector, sensitivity: >40000 mv maximum acquisition rate: 4 ms, maximum operating temp: 400 cgas cylinders & fittings, gas sampling: zero air, h2, n2 and helium gas cylinder with 2-stage regulators, each 1 no. four-stage gas purification panel and gas tubing. quote a suitable gas sample injector apparatus for the analysis of co2 gas, gas standards and a suitable packed column quote a 6-port gas sampling valve suitable for both manual (through syringe) and auto injection (online) quote sample line, sample loop, heated lines, filters, safety hydrogen purging, and flow control of gas. calibration gasses: suitable gas standards such as ar, he, h2, o2, co and ch4 should be providedpc and ups: pc i5 (or higher), 8gb ram, 1tb hdd, 22-inch led monitor (or higher), ssd: 512 gb, windows 10 os (or higher), wired keyboard and mouse. laser printer b/w, online ups sine wave capacity of 5 kva with battery power backup of 1 hour should be provided by the supplier general terms and conditions:warranty: 3 years manufacturer s warranty certificate. vendor should be an authorised provider of sophisticated high-precision chromatograph workstation systems for the past 15 years or more with: a proven track record in multiple countries and national institutes standard quality certifications such (iso 9001) 5+ past installations of similar systems in india. compliance statement should be enclosed with the quotation. the installation should be done at free of cost. hands-on training for 1 day for two trainees (faculty and scholars) must be provided on operation, maintenance and troubleshooting to two to two-three persons at the site of installation. if required, hands-on training must also be given to our faculty/scholars at a later stage, without any financial commitment to university. the technical details of the quoted instrument must be available on the official website of the principal supplier. the vendor should provide the list of end-users (recent) with contact details. the vendor must submit the latest reference letters from their previous users. trained service engineers in india (with suitable certificates) for the quoted model must be readily available to resolve the technical problems. a list of recent scientific publications in reputed journals from the user institutions where the quoted mode

CTN :42950501 Due date: 03 Dec, 202503 Dec, 2025 3.00 Lacs
Tender For rough cost estimate of providing fire alarm system for newly constructed record room in judicial complex at narnaul.

CTN :42860802 Due date: 12 Dec, 202512 Dec, 2025 NA
Tender For supply of system mounting platform with record storage facility c c - premier suit desk with pedestal plus return desk unit eru size , return desk eru 1200w by 450d by 610h , cross high back chair , cross full back chair , sofa 3 seater 1820w by 840d by 480760h , vertical storage door unit vsdu 2 size 735h by 900w by 450d , workstation t shape size 3600 by 600 1000 by 600 , table with eru and pedestal size 2100w by 2250d by 750h , tambour door unit size 1200w by 460d by 1170h , tambour door unit size 900w by 460d by 1170h , plus sofa 2 seater 1450w by 840d by 480760h , table with eru size 1650w by 1650d by 750h , table with eru attached pedestal size 1800w by 2100d by 750h , unitised 10 seater meeting table , 5 drawer unit , workstation l shape size 1350 by 750 1200 by 450 , motion chairs , 3 drawer pedestal unit , compactor 2 bay size 2047h by 2400w sd2hyphen1no td2hyphen2no ld2hyphen1no , compactor 2 bay size 2047h by 2400w sd2hyphen1no tdhyphen4no ld2hyphen1no , 3 seater sofa 0dot92d by 2dot05w by 0dot91h meters , periodical display unit size 1890h by 290w by 400d , teapoy 600wby600dby450h , teapoy 900wby600dby450h , tv bottom stand 2000wby300dby750h

Central Government/Public Sector

CTN :42763899 Due date: 09 Dec, 202509 Dec, 2025 NA
Tender For supply and installation of 02 channel voice data recording and processingunit (vdrpu) as per rdso /spn / tc / 38 - 2002 ver 2 or latest.supply and installation of vhf receiver to record communication with in the radio coverage area of station vhf equipment. note: vhf based secured communication equipment has in-built vhf radio which is configured on dg (driver guard) frequency to record communication. if railways also wants to record communication on shy frequency simultaneously, then this is required per location.supply of server hardware and software for centralized monitoring of voice communication with voice logging for entire stations in nagpur division through vhf based secured communication equipment as per no rdso / spn / tc / 38 - 2002 ver 2 or latest amendments or latest. the technical specification is as follows: - (i). processor - intel core tm i7-6700t, memory: 16gb, hard drive: 1 tb ssd, graphics card: nvidia geforce gt 730 (4 gb ddr3 dedicated), networking 802 m, 11 b/g/n (1x1) and bluetooth 4.0 m. 2 combo, sound card: dts studio sound?, keyboard, and mouse: hp usb wired keyboard with volume control, power supply: 180w ac power adapter, audio: dts sound?, memory slots: 2 dimm , external i/o ports: 2 usb 3.0; 4 usb 2.0 dimm, windows 11 operating system, led monitor: 24 (23.08

State Government

CTN :42756409 Due date: 05 Dec, 202505 Dec, 2025 NA
Tender For purchase of sports exercise physiology lab equipments - wearable physiological monitoring system (01 sensors) (pac), should be able to work in lab and field studies (portable and easy to carry). the system should be able to record the below parameters wirelessly (2 ecg signals, acceleration -3axis, respiration, skintemperature, gsr, spo2, ppg) should have high adc resolution the system should provide real time data recording with online and offline analysis should have at least 8 hours of operation in full transmission mode. option for external battery pack. automatic heartrate variability analysis. online and offline from human subjects. online and offline ecg analysis for all ecg intervals, plots etc. telemetric transmission should be minimum100 meter not less than that. should provide frequency and time domain hrv analysis with automatic plots generation like tachogram plot, rr, histogram plot, delta rr, histogram plot, poincare plot, power spectrum plot etc. the software for recording the data and analysisthe data should be same. four force sensor balance board for body sway analysis that communicate with the same software via bluetooth for analysis and recording. both wireless system and force sensor balance board should work on same software simultaneously and independently for recording and analysis as per user demand. should have software-controlled filtering high pass, low pass filters, ac coupling, digital filters, band pass filter and main filters. display modes: must have simple chart view, scope view, xy view, zoom view, fft, spectrum, averaging view etc. the software should have built in smart analysis features like power spectrum, template matching, curve fitting, cross correlation etc. facility to perform complete heartrate variability analysis (time and frequency domains) online and offline, ecg interpretation, pqrst amplitudes and st elevation, cardiac axis analysis during exercise. cyclic measurement: rate period, frequency, count, minimum, maximum, height, integral, variance, derivatives, arithmetic and mathematic formulae iso and european iec certificates to be provided

CTN :42720711 Due date: 04 Dec, 202504 Dec, 2025 NA
Tender For supply of gnss rf record and playback system and signal generation software

CTN :42651893 Due date: 04 Dec, 202504 Dec, 2025 NA
Tender For gnss rf record and playback system and signal generation software
 Loading, Please wait...

Connect us via What's Up