Get complete information related to latest Starter Panel Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Starter Panel Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Starter Panel Tenders.
Tender For work of construction of 3 no new 200 mm dia tube well, deepening of existing tube wells, replacement of mono block pump set and starterpanel at mvs kheda-norangpura--tewri-sewro ki dhani--bhamod with 24 months defective liability
Tender For e-tender for proposed modernisation works of interiors, civil, modular furniture and chairs, electrical installations, data and tel. cabling, fire alarm system including toilet and staircase renovation at do and bo bongaigaon.
Tender For supply, installation, testing and commissioning of electro mechanical works of pumping machinery with associated mechanical and electrical equipments, instruments & accessories etc for different head works of vapi municipal corporation area. - item no.1: submersible type pump setsupply, installation, testing and commissioning of submerged submersible pump sets with suitable for working on three phase, 50 hz3percentage ,415v10percentage ac supply, suitable rpm with 3 core flat copper cable from pump to starterpanel with cable end terminations, all supports, clamp, pipe fittings, mechanical seal, bearing bush, strainer, pump sensors and other protection, pump control unit etc. suitable construction of foundation/ installation device with cable length from pumps to panels and of following material of construction:m.o.c :- casing : ci, impeller : ss cf8m, wearing ring and bearing bush : bronze, tc mechanical seal, cs/ss bearing, ss shaft with sleeve, ss strainer and ms motor body fasteners : ss 316l, guide rail : ss 316, lifting chain : ss 316capacity of pump - 833 lpm and 35 m. head (15 kw/ 20 hp) - 1 working + 1 standby. the price should include water in oil sensor and io 113 for mechanical seal and motor protections suitable for each pumps., capacity of pump - 1667 lpm and 35 m. head (18.5 kw/ 25 hp) - 1 working + 1 standby, capacity of pump - 2083 lpm and 35 m. head (22 kw/ 30 hp) - 1 working + 1 standby, capacity of pump - 2500 lpm and 35 m. head (22 kw/ 30 hp) -(only supply of pump set - without installation), capacity of pump - 3333 lpm and 35 m. head (30 kw/ 40 hp) - 1 working + 1 standby, capacity of pump - 5833 lpm and 35 m. head (48.75 kw/ 65 hp) - 1 working + 1 standby, capacity of pump - 8333 lpm and 35 m. head (75 kw/ 100 hp) - 1 working + 1 standby, capacity of pump - 7333 lpm and 45 m. head (82.5 kw/ 110 hp) - 1 working + 1 standby, capacity of pump - 11111 lpm and 35 m. head (90 kw/ 120 hp) - 1 working + 0 standby, capacity of pump - 11111 lpm and 35 m. head (90 kw/ 120 hp (only supply of pump set - without installation), capacity of pump - 14286 lpm and 35 m. head (110 kw/ 150 hp) - 1 working + 1 standby, capacity of pump - 16667 lpm and 35 m. head (132 kw/ 180 hp) - 2 working + 1 standby, capacity of pump - 25000 lpm and 26 m. head (150 kw/ 200 hp) - 1 working + 1 standby, item no.2: submersible non-clog vertical pumpsupply, installation, testing and commissioning of sewage submersible, non clog type suitable for working on three phase, 50 hz 3percentage , 415 v 10percentage , ac supply, 1450 rpm synchronous speed with 3 core flat copper cable from pump to starterpanel with cable end terminations, all supports, clamps, pipe fittings along with mechanical seal, bearing bush, strainer etc. complete set and following m.o.c: casing: ci, impeller: ss cf8m, wearing ring and bearing bush: bronze, tc mechanical seal, cs / ss bearing, ss shaft with sleeve, ss strainer and ms motor body.capacity of pump - 15 kw/ 20 hp - 2 working the price should include water in oil sensor and io 113 for mechanical seal and motor protections., item no.3: manufacture, supply, lowering, laying, jointing, welding and delivery of electric resistance welded (up to 400mm)/submerged arc welded(above 400mm) m.s.pipe having bevelled ends plate or coil conforming to is-3589-2001 or its latest revision/ amendment for following thickness outside diameter at gwssb store or site anywhere in gujarat state including all taxes, insurance, transportation, freight charges, octroi, inspection charges, loading, unloading conveyance to departmental stores, stacking etc. all complete charwada 2 - jalaram mandir - 219.1 mm dia. (4.5 mm thick)- delivery pipe, balitha 1 - near kabrsthan - 273 mm dia. (5 mm thick)- delivery pipebalitha 2 - bhandarwada - 273 mm dia. (5 mm thick)- delivery pipechhiri 1 vallabh nagar - 273 mm dia. (5 mm thick)- delivery pipe, dungra - azad nagar - 323.9 mm dia. (5.6 mm thick)- delivery pipe vapi - naikwad tanki - 323.9 mm dia.
Tender For repairing and rewinding of 7.5 hp, 10 hp, 12.5 hp and submersible motor pump set with supply of cable , starter, panel and other electrical items for ward no.26 under mcg. recall
Tender For work of construction of 3 no new 200 mm dia tube well, deepening of existing tube wells, replacement of mono block pump set and starterpanel at mvs kheda-norangpura&95&95tewri-sewro ki dhani&95&95bhamod with 24 months defective liability
Tender For work of construction of 3 no new 200 mm dia tube well, deepening of existing tube wells, replacement of mono block pump set and starterpanel at mvs kheda-norangpura and tewri-sewro ki dhani and bhamod with 24 months defective liability
Tender For day to day operation and guarding of the pumping machinery through manual motor starterpanel at zone i p.h. no. i and ii, zone ii p.h. no. i and ii under mahalandi w/s scheme,block-kandi , zone i p.h. no. i and ii under godhanpara w/s scheme, bloc
Tender For repairing and rectification of motor starterpanel works including supplying required materials at different w/s scheme as baharal,magura ,mahanandapur etc in the district of malda under malda mechanical division, phe dte.
Tender For urgent repairing and overhauling of 4 nos motor starterpanels along with electrical wiring and other allied works at ls-vi (charu avenue) dps under pbps (drg)s and d.