Get complete information related to latest Steel Conductor Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Steel Conductor Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Steel Conductor Tenders.
Tender For corrigendum : construction of transmission line - pcc poles supply and erection of pre-stressed cement concrete pole of suitable length with a given planting depth confirming to is-1678_1960_1978 below ground level in excavated pit of suitable dimensions complete in all respect as approved by engineer_in_charge at site pcc pole overall length 11 metre , planting depth 1.80 metre , w_l 400 kg pb csr 2020 item no 34.32(iii) , insulators supply and erection of insulators confirming to is_2544 and 5350 (test certificates of cpri) includes supply and erection of nuts bolts and other accessories whatsoever required at site for fixing it to the structure pole. the job is to be completed as approved by engineer_in_charge 11kv pin insulator with gi pin pb csr 2020 item no 34.35(i)(b) , stay sets supply and erection of stay set consisiting of 19_20mm dia.of suitable length gi stay rod duly threaded upto 300mm at one end and shaped on the other end ms plate size 30cm x 30cm x 6mm with 20mm dia hole drilled in the centre of the plate gi stay wire size 7_10 swg , gi thimble for stay binding , egg_strain insulator , ms elbow made out of 16mm plain sheet and a 20cm long piece of 50mm x 50mm x 6mm angle iron made to the shape as approved by engineer_in_charge. stay set complete shall be fixed to the pole by providing suitable size full clamps made out 50mm x 6mm size ms flat with required number of nut and bolts 16mm dia on one end and shall be embedded on the other end. the stay plate shall be covered with cement concrete having total volume of the concrete not less that 0.042cum. the job shall include excavation of pit and back filling and after pouring concrete with excavated soil etc. as approved_desired by the the engineer-incharge stay set consisiting of 19_20mm dia 2.4 metre long gi stay rod pb csr 2020 item no 34.35(ii)(b) , acsr conductor wolf 150mm2 , pole top brackets (galvanised) , v-shape cross arm 100x50mm , half clamp ms flat 50x5 , 11 kv polymeric disc insulators 70kn , danger plate , phase plate (set of 3) , barbed wire , earthing arrangement of 11kv poles , eye screw bolts 9inchx5_8 inch(galvanised) weight 0.483 kg. , nut and bolt ms off size , ms channel 100 x 50 x 6 - 2400 mm (galvanised) for h-pole , belting for h-pole 50 x 50 x 6mm . (galvanised) weight 9.90 kg , bracing for 4-pole 50 x 50 x 6mm . (galvanised) weight 14.49 kg , single tension fitting complete suitable for acsr wolf , pg clamp , full clamp ms flat 50x5 , ms angle 65x65x6 , erection charges
Tender For corrigendum : the work of supply & erection/installation of tail less unit, d.o. fuse set, boots and sleeves & diffrent types of material use in dtr protection (bp 2024-25 phase-ii) edd i & edd (rural) kasganj under the juridiction of edc, kasganj on semi turn-key basis. - supply of material by the contractor, do fuse set, m.s. top channel (125x65x2240 mm.), holding clamps for ms top channel, tail less unit 500a/650v with fitting suitable for pcc/stp pole., nut, bolt & washer, m.s. angel with clamp and nut & bolt, m.s. earthing with earth rod as per respo norms, boots & sleeves, al lugs 120 sq.mm, distribution panel box no.2 circuit with stud type tail less unit 500 amp, 650 v with brass holding studs, copper contacts, height of tail less unit 48 inch width 3 inch and pannel size h-1650+300 mm, w-750 mm, d-520 mm & thickness of crca sheet gauge 14x16 along with alu busbar of size 50x6 mm for phases & neutral with color code heat shrink sleeve and mounting stand of 40x40x5 mm ms angle with earthing arrangement., distribution panel box no.3 circuit with stud type tail less unit 500 amp, 650 v with brass holding studs, copper contacts, height of tail less unit 48 inch width 3 inch and pannel size h-1650+300 mm, w-1400 mm, d-520 mm & thickness of crca sheet gauge 14x16 along with alu busbar of size 50x6 mm for phases & neutral with color code heat shrink sleeve and mounting stand of 40x40x5 mm ms angle with earthing arrangement., safe carriage of following/ any other material from electricity store center soron/etah/aligarh to pit site of work from the kaccha & pakka road including loading & unloading at the respective ends including the cost of arrangement of labour, t&p etc. which required for topper completion of work., lt xlpe cable al. 1x120 sq.mm., acsr weasel conductor for jumpering, erection of material, erecetion/installation of d.o. fuse set, fixing of m.s. top channel (125x65x2240 mm.) with all accessories., foundation of distribution panel box no.2 circuitwith fixing arrangement & replacement of cable with lugs., foundation of distribution panel box no.3 circuitwith fixing arrangement & replacement of cable with lugs., fixing of tail less unit 500a/650v with fitting suitable arrangement like bus bar etc. for pcc/stp pole., erection of m.s. earthing with earth rod as per respo norms.
Tender For corrigendum : supply of pcc pole 8.5 mtr. long,stp pole 11 mtr. long,stone pad ,11 kv v type cross arm,11 kv cross arm clamp with n&b,11 kv pin insulator,11 kv g.i. pin with n&b,f-bracket,earthing of pole,acsr rabbit conductor,acsr weasel conductor,11 kv xlpe cable 3x185 sq.mm.,11 kv cable jointing kit o/d for 3x185 sq.mm. cable,stay set complete,t-off channel,clamp for t-off channel,11 kv disc insulator,11 kv disc fitting,concreating of pole,danger plate complete,barbed wire gi 1/2 per pole,dismantling and removal of existing conductor/cable/gi wire from the various area preparing their coils and then stacking in the respective jes (store) as per direction of supervising engineer. it includes the work of cartage, cost of labour, t&p carrier etc. required for proper completion of work.acsr weasel conductor scrap,steel & scrap,g.i. wire scrap,11 kv 3x185 sq.mm. xlpe cable scrap
Tender For bid to ras supply of installation of 16 meter led security high mast light - supply install and testing 16 meters, high mast with double drum winch and stainless steel rope , earthing complete with galvanized steel earth plate electrode of size 60cm x 60 cm x 6 mm , supply and fixing led flood lights luminaire with secondary optics made in pressure die cast housing and heat sik in aluminum extrusion of 1 x 210 watt led light fittings ip-67 and ip 68 , supply, laying, jointing and testing lt, xlpe insulated, armored heavy duty cable with stranded aluminum conductor suitable for rated voltage of 1100 volts grade , excavation in trenches in soft or loose soil , returning, filling in with excavated soil, including spreading, leveling, watering and well ramming in layers , removing excavated material soil , m and l for sand cushioning to pvc or xlpe cable , 32 mm pvc sanitary pipe for covering 11kv heavy duty cable , m and l for brick protection over to lt underground cable , supply, install, testing and commissioning of lt panel of size 60 cm x 60 cm x 6 mm cm outdoor
Tender For repair maint of lt panels, switchgears, lt cables and connected items of different otm accns incl apfc panels lighting conductor, earthing, traffic signal lights incl connected works at rrc sub stn, sub stn no 1,3,4,5 ,6 at fw under ge fw kolkata
Tender For corrigendum : special repair for renewel of e/m items and plant/ machinery held in charge of age (e/m) rnd agra cantt under ge (i) rnd delhi - supply , installatation , testing and commissioning of diesel driven generating set to give an out put of 500 kva, 415v ac supply 3 phase, 50 hz, 4 wire radiator mounted on common base plate complete with fuel tank, vibration damper and other accessories with fuel tank viberation damper and other accessories with acoustic enclouser as per latest cpcb-iv norms and amf panel including pcc foundation work as per oem reccommandation and taking out the old dg set from the location and deposited to mes store yard complete all as specified and directed, interanally comprising of following :-(a) diesel driven engine :- developing a net output suitable matched to give a net rated output of minimum 604 hp/suitable to drive 500 kva alternator, at 0.8 power factor 415 volts. the engine should be capable of delivering the required output at 1500 rpm, water cooled, self start, with a provision of 10% overload for one hour in every 12 hours with the following accessories and all as specified.(i) fly wheel to suit flexible coupling and fly wheel housing.(ii) air cleaner complete as per manufacturer specification. (iii) fuel injection pump. (iv) flexible coupling with guard, nuts and bolts.(v) fuel filter with mounting. (vi) oil filter with mounting.(vii) starter motor as per manufactures design.(viii) exhaust, silencer industrial type with exhaust pipe suitable length.(ix) batteries 12 volts 2x180 ah maintenance free batteries with copper lead, terminals etc.(x) instrument panel complete with microprocessor based controller comprising shut down valve indication, lcd hour counter indication, rpm indication , led lamps for fail to start, over speed /under speed . low lub oil pressure, high engine coolant temperature. gaugae.(xi) dynamo/alternator suitable rating., (b) alternator :-the above engine will be coupled through flexible coupling on an indigenous alternator mounted on a strong steel fabricated common base frame suitable for mounting in an acoustic enclousre. the alternator will be 3 phase 50 hz 1500 rpm self regulating self exciting type and have class h insulation of stator and rotor windings and generate 500 kva output at .8 power factor 4 wire 415 volts ac supply under ntp condition with a provision of 10% overload for 1 hour in every 12 hrs running. the alternator would be screen protected and fitted with shield ball/roller bearing, automatic voltage regulator.(c) control panel :- s&f amf (automatic on mains failure) control panel cpri approved outdoor ype kiosk water, dust and vermin proof and fabricated out of 3.15 mm thick crca sheet and 50mm x 50mm x 6mm angle iron powder coated suitable for 415 volts 3 phase 50 hz ac supply with and incl the following :-(i) mccb of suitable capacity(ii) necessary relays, times and power contractors of suitable rating/capacity for auto on-off the dg set and changeover of the load in case of power failure.(iii) digital mulfifunctional meter for phase wise reading of amps, voltage kwh and frequency -01(iv) internal wriring with single core solid copper conductor cable of appropriae gauge incl mumbering ferrules and control fuses.(v) earthing terminals 02 nos(vi) auto/manual start switch to by pass auto start.(vii) battery charging system suitable for charging for charging the battery provided with the dg set incl boost/stickle switch and system, dc voltmeter digital type., (d) fuel tank :- one no built in sheet metal steel tank mounted inside the acoustic encloser and of adequate capacitynot less than 740 ltr with inlet and outlet connection including the following :-(i) level indicator with float and gauge.(ii) fuel piping for fuel supply to engine and over flow to tank(iii) fuel strainer(e) acoustic enclosure :- enclousre be designed for reducing the sound level up to 75+/ 5db (average) as per is 8528 part 10 and as per approved cpcb morms. the acous
Tender For segregation of 11 kv mixed feeders at tonk circles of jaipur discom of rajasthan state under revamped reforms-based and results linked distribution sector scheme (rdss) on turnkey basis against tn-583 - pcc poles, pcc pole 9 mtrs long (400 kg), pcc pole 9 mtrs long (200 kg), outdoor 11 kv o/d vcb kiosk complete with accessories including use of special tools, armoured cable of size 2c x 4 sq.mm. 1100 volts pvc insulated including supplyof ferrules, control cable of size 12c x 2.5 sq.mm. 1100 volts pvc insulated including supply of ferrules, overhead steel cored aluminum acsr dog[100sqmm(6+7) /(4.72+1.57)] conductor complete in all respect as per latest specification and drawing, overhead steel cored aluminum acsr rabbit conductor in all respect, earthing rod sets for s/s made with ms rod (galvanized ) 20 mm dia, 3 meter length with gi wire and clamp as per latest specification and drawing adopted & approved by nigam., ctpt structure set (galvanized), 11kv ct pt set(200/5 amp.), mip meter box for meter with ttb, go double break without eb isolator on existing bracket complete in all respect as required including hardware, nut, bolts & washer etc., 11kv ( with 9 x 24 kv post insulator ) 400 amp., horn gap sets on existing brackets in all respect as required including hardware nut & bolt & washer etc., 11kv ( with 6 x 24 kv post insulator ) 1 set=3 nos, supply of insulators, 11kv porcelain disc.insulators b&s type 45kn, hardware for 11kv disc insulator b&s type 45kn, composite polymer insulators, 11kv polymer disc.insulators t&c type 45kn, hardware for 11kv disc insulator t&c type 45kn, 11 kv composite polymer pin insulator complete in all respect, pg clamps for suitable acsr dog conductor, pg clamps for suitable acsr rabbit conductor, 11 kv danger plate of size 200 x 250 mm complete in all respect, supply of angle and channel, m.s channel 100x50x6 mm, m.s channel 75x40x6 mm, m.s. flat 50 x 6 mm (galvanized), 1.4 mtr channel bracket with clamp, supply of lightening arrestors, substation type 9kv, 10ka station class (1set=3 nos.) lightening arrestors., 11kv double pole line structure set for cut point complete on existing poles in all respect with clamp, as required made from m.s.channel 100 x 50 x ismc ( 9.56 kg. per mtr.) isa m.s.angle 65 x 65 x 6 mm, m.s.angle 50 x 50 x 6 mm and m.s.flat 50 x 6 mm (galvanized as per is), gi stay set (galvanized) complete (stay rod 16 mm dia,1.8 m long,anchor plate 300x300x4 mm,12 mm dia turn buckle) including stay clamps,, strain/guy insulator for stay set, 7/10 swg gi stay wire, gi wire 8swg, underground cable for working voltage of 11kv aluminium conductor (is 7098) cable xlpe armoured, under ground cable of size 3x185 sq.mm for 11 kv, g.i. pipe of 125 mm diameter, b-class (is:1239 mark), gi pipe for cable support at pole ( each 3.3 mtr ), cable for11 kv aluminum conductor xlpe armoured ht cable, xlpe 3x185 sq.mm h.s. on indoor type, xlpe 3x185 sq.mm h.s. on outdoor type, xlpe 3x185 sq.mm h.s.s.t. joint, 11.4 mtr. long lattice tower made of 50 x 50 x 6 mm m.s. angle with 50 x 6 mm m.s. flat for bracing as per nigam specification, 11kv cross arm with top hamper with clamps made of ms angle 65x65x6mm, clamp 50x6 mm, earth clamp 50x6 mm (galvanized), fixing of 11/0.4 kv substation structure set for three phase 63 kva transformer on double poles in all respect. weight (as per specification and drawing with go channel) approx=219.54 kg (all galvanized as per relevant is), 11 /0.4 kv al wound, three phase distribution transformer (completely self protected with provision of lt bushing box), 25 kva, 63 kva, 6.35/0.24kv s/s structure set for single phase transformer on single 9mtr, 400kg pcc pole in all respects., 11kv 100 amp drop out cum isolator with 3.0 amp. fuse & 12 kv post insulators., lt xlpe cable, size 4cx70 sq. mm, size 4cx120 sq. mm, aerial bunched cable, aerial bunched cable 3cx25+1x25 sqmm, aerial bunched cable 3cx50+1x35 sqmm, lt distribution pillar