Get complete information related to latest Steel Cord Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Steel Cord Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Steel Cord Tenders.
Tender For corrigendum : term contract for communication and networks inside be factory and estate. - supplying of the 6 pair under ground telephone cable pvc insulated, pvc sheathed, wire / strip armoured and overall pvc sheathed with standard colour code of 0.51 mm dia atc conductor and laying the same directly on wall / structure / terrace with clamps / in the trench / duct etc., as required / as directed by engineer-in-charge. (note:- excavation of trench for laying below ground, refilling , supplying and laying of bricks on sides and at top of cable, shall be measured and paid, supplying of the 20 pair underground telephone cable pvc insulated, pvc sheathed, wire/ strip armoured and over all pvc sheathed with standard colour code of 0.51 mm dia atc conductor and laying the same directly on wall / structure / terrace with clamps / in the trench / duct etc., as required / as directed by engineer-in-charge. (note:- excavation of trench for laying below ground, refilling , supplying and laying of bricks on sides and at top of cable, shall be (measured and paid seperately ), supplying of the 50 pair under ground telephone cable pvc insulated, pvc sheathed, wire / strip armoured and over all pvc sheathed with standard colour code of 0.51 mm dia atc conductor and laying the same directly on wall/ structure / terrace with clamps/ in the trench/ duct etc., as required / as directed by engineer-in-charge. (note:- excavation of trench for laying below ground, refilling , supplying and laying of bricks on sides and at top of cable, shall be measured and paidseperately.), supplying of the 100 pair under ground telephone cable pvc insulated . pvc sheathed, wire / strip armoured and over all pvc sheathed with standard colour code of 0.51 mm dia atc conductor and laying the same directly on wall / structure/ terrace with clamps / in the trench / duct etc., as required / as directed by engineer-in-charge. (note:- excavation of trench for laying below ground, refilling , supplying and laying of bricks on sides and at top of cable, if required shall be measured andpaid seperately), laying only of 3 pair telephone cable of departmental supplied released telephone / communication / computer /data/punching clock cable in the already existing trench / pipe / duct / on wall/ truss etc.,as directed including providing suitable clamps, guttas, bolts, nuts etc., wherever required as directed by engineer in- charge. (note:- excavation of trench , refilling etc., providing and laying of sand, bricks etc., shall be measured and paidseperately), laying only of 6 pair telephone cable of departmental supplied released telephone/communication /computer /data/punching clock cable in the already existing trench / pipe / duct / on wall/ truss etc.,as directed including providing suitable clamps, guttas, bolts, nuts etc., wherever required as directed by engineer in- charge. (note:- excavation of trench , refilling etc., providing and laying of sand, bricks etc., shall be measured and paid seperately.), laying only of 10 pair telephone cable of departmental supplied released telephone /communication/computer /data/punching clock cable in the already existing trench/ pipe / duct / on wall/ truss etc.,as directed including providing suitable clamps, guttas, bolts, nuts etc., wherever required asdirected by engineer-in-charge. (note:- excavation of trench , refilling etc., providing and laying of sand, bricks etc., shall be measured and paid separately.), laying only of 20 pair telephone cable of departmental supplied released telephone /communication/computer /data/punching clock cable in the already existing trench/ pipe / duct / on wall/ truss etc.,as directed including providing suitable clamps, guttas, bolts, nuts etc., wherever required as directed by engineer-in-charge. (note:- excavation of trench , refilling etc., providing and laying of sand, bricks etc., shall bemeasured and paid seperately.), laying only of 50 pair telephone cable of departmental supplied relea
Tender For corrigendum : supply of pvc insulated copper cable single and multi - core circular sheathed cable with flexible conductor (v2) as per is 694 (q2)
Tender For supply of repair kit for hot splicing of steelcord conveyor belt of width 1800mm, strength-2500kn/m, , repair kit, f/hot splicing sc conv: 1200mm for hot splicing of steelcord pipe conveyor belt of width
Tender For supply of item 10 , item 20 , item 30 , item 40 , item 50 , item 60 cable,trg,atc,3.3kv gr,3.5cx50mm2,is9968 size & tvpe 3.5cx50 sq. mm 3.3 kv grade flexible atc conductor of class-s, epr le-3, insulated &black hofr nbr pvc type se-4 sheathed flexible trailing cable suitable for reeling/un-reeling operation. cable type- flexible, standard: is 9968(part 2) 2002 d.c. resistance at 20deg. c (ohms/km) power core max- 0.393 earth core max - 0.795. annealing test in %- (before stranding) 13.5 %. per sulphate test in g/m2- max. 5.00. conductor screeninq power core only material approx thickness mm - extruded semiconducting compound/ extruded semi conducting tape- 0.80. conductor material: annealed tinned copper, 6.6 klv grade, cable type: flexible, standard: is 9968(part 2) 2002 tests on insulation thickness (nom) mm core ldentification - power core-2.20 colour rpct red, yellow & blue for power cores & green for earth core tensile strength before ageing n/mm2- min.4.20 % variation after ageing (air oven)- max. +-30% % variation after ageing in (air-bb)- max. +- 30%. elongation before ageing in % - min.200% % variation after ageing (air oven)- max. +- 30% % variation after ageing in (air-bb)- max. +- 30%. hot set test hot set elongation- 175% permanent set 15%. lnsulation resistance constant (min.) m ohm km. at 27deg.c- min. 3670 at 90 deg.c-min 3.67. thick of lnner sheath min 2.00 mm. rein forcement- open braid of textile material physical test on outer sheath thickness (nom) / min mm- 3.50/ 2.60 colour black, over all diameter of cable mm- 52.00+-3.00. tensile strength ) /bid number : gem/2025/b/6811700 * /dated: 24-10-2025 & & / bid document 1 / 22 before ageing n/mm2 - min. 11.0 at 2oo elongation 4n/ sq. mm. % variation after ageing in (air-bb)-max. +- 50% elongation before ageing in %- min.250% % variation after ageing in (air-bb)- max. + 50%. hot set test hot set elongation- max.175% permanent set- max 15. oil resistance test variation in % in tensile strength- max. +-40% variation in % in elongation-max. +-40%. tear resistance in n/mm - min.5.0. flammability test period of burning after removal of flame- max. 60 sec. min unaffected portion from the lower edge of the top clamp - min 50 mm. test high voltage at room temp- 10 kv ac for 4 hours. water absorption test increase in capacitance 1 to 14 days max- 6% 7 to 14 days max- 2.5%., control trailing cable 12 c x 2.5 3 p x 1.5 (pair screened) 2 voltage grade 1.1 kv 3 reference standard generally confirming to is: 9968 (part- 1)1998 4 conductor a. material to is:8130/84 annealed tinned copper b. nominal area of cross section(sq. mm) i)-unscreened core (sq. mm.) 2.5 ii) - screened pair (sq. mm.) 1.5 c. flexibility class as per is:8130/84 class-5 d. maximum dc resistance of conductor at 20 deg. c i)-unscreened core (ohms/km) 8.21 ii)- screened pair (ohms/km) 13.7 5 insulation i) material epr type ie-2 to is:6380/84 ii) nominal thickness (mm) 1.0 6 two cores of 1.5 sq. mm. size twisted together to form a pair yes. 7 individual pair screening each pair of 1.5 sq. mm. size taped with rpct, screened with 0.2 mm nom dia of annealed tinned copper wires braid, taped with melinex tape. yes. 8 no of cores / pair i)-unscreened cores 12 ii)-screened pairs 3 9 identification of power cores by number printing on cores. 10 laying up (i) three screened pairs laid up together, taped with rubber proofed cotton tape to form group as "a" (ii) 12 unscreened control cores laid up together around group as "a" of screened pairs and taped with rubber proofed cotton tape applied with open spiral. 11 inner sheath a) material to is: 6380/84 hd hofr csp type se-4 b) minimum thickness (mm) 1.6 12 an open braid of nylon cord reinforced in between inner and outer sheath. yes. 13 outer sheath a) material to is: 6380/84 hd hofr csp type se-4 b) nominal thickness (mm) 2.5 14 nom. overall diameter of cable (mm) 33.0 tolerance on nom. overall diameter (mm) /- 2.0 15 max. safe pulling tension lo
Tender For bid to ras supply of modular 5 kg capacity filled with clean agent gas hfc 227 , modular 15 kg capacity filled with clean agent gas hfc 227 , modular 15 kg capacity filled with clean agent hfc 227 , modular 10 kg capacity filled with clean agent hfc 227 , conv heat smoke detector , conv manual release switch , conv manual abort switch , 2 zone conventional single area gas release panel with battery relay and smps , conv hooter cum flasher , supply of pvc insulated pvc sheathed frls copper armoured aluminium conductor of cable as per is 1554 part i of size 2 x 1 point 5 sq mm
Tender For bid to ras bid to ras corrigendum : supply of upgradation of central substation for es dept at grse main works d d - supply of upgradation of central substation for es dept at grse main works d d - ht copper bus bar , vcbs items , wti,buchholz, oti relays , 3 core x 300 sq. mm. aluminium conductor , pvc hume pipe , new two - 02 nos transformers , 11 kv - e 3 c x 300 sq mm frls xlpe , earth pit item 50 mm dia gi pipe , copper earth plate for neutral earthing , 50 x 6 mm cu flat , 50 x 6 mm gi flat , 2 v 100 ah ni-cd battery , 110 v dc rectifier , buchholz, wti, oti relays for 1k kva transformer , hv cable route marker , mapping of existing cable and pipe lines , civil work for preparation of renovation , position of 06 vcb racks , ht copper bus bar , installation and proving of wti, buchholz, , repair of vcb enclosures , 3 core x 300 sq. mm. aluminum conductor , trench cutting for cable laying , charge for laying of hume pipe , removal of 02 nos. transformer - 1000 kva and position of 02 nos. new transformer , ht cables , earth pit connection , installation of batteries , removal of existing ht panel. , service for removal of existing panel , service for fitment and proving of buchholz, wti, oti relays for 1000 kva transformer , cea approval for new vcb panel and ht cable installations ) /bid number : gem/2025/b/6602235 * /dated: 23-08-2025 & & / bid document 1 / 40