Tender For supply of two way centre off change over switch, 40 amp, 4pole, 415 v, with mcb box 4 pole (one mcb and one mcb box) for air conditioner breaker of locomotives. make : l&t (or) siemens (or) abb (or) schneider(or) c&s only
Tender For supply of a1515swt99701001 charging module 24-75 with accessories dc power system 02130674 -part code-888800000024. as per scope of supply sl no 01 , a1515swt99701002 acu with controller ngmc-hf 2x2u front panel -lcd plus 3leds plus 4 buttons- and box mb2 plus ob2 plus db2 part 820d-part code-2440253. as per scope of supply sl no 02 , a1515swt99701003 ib2 customer input output board for ngmc 02351757 -part code- 2351757. as per scope of supply sl no 03 , a1515swt99701004 switch disconnector 63 amp 415 vac 3 pole on-off -part code- 286706383020 as per scope of supply sl no 04 , a1515swt99701005 circuit breaker - miniature- 10 amp- 230 by 400 vac 1 pole- c curve- 6 ka din mounting -part code- 280200106111. as per scope of supply sl no 05 , a1515swt99701006 circuit breaker- miniature- 25 amp- 230 by 400 vac 1 pole- c curve- 6 ka din mounting part code- 280200256110. as per scope of supply sl no 06 , a1515swt99701007 relay miniature 6 amp, coil voltage 24 vdc with 3 change over contacts- part code - 285431030600. as per scope of supply sl no 07
Tender For supply of mpcb (motor protection circuit breaker) of current rating: 1.6 amps, thermal release range: 1.1 to 1.6 amps, class-10, breaking capacity: 50 ka, 3 pole, voltage rating 415 v ac with 01 no + 01 nc auxiliary contact block as per rdso spec. no. rdso/pe/spec/ac/0184-2015 rev.1 to abb model no.:ms132-1.6b, schneider model no. gv2me06, l&t model no. st41894oooo, siemens model no. 3rv2011-1aa10 and eaton model no. pkzm0-1.6.
Tender For supply of siemens spare - 3925463, 3.000, spare rear side ruckwand required for 3200 a air circuit breaker.material name : rear side ruckwand,3wt acb, 3200a, size:iimake : siemenspole : 4, 3941826, 1.000, material name : verticle terminal contact,3wt acb, 2500a.no of pole : 4make : siemensmlb:3wt98234ac00oty:1 is equal to 1set is equal to 4 nos.
Tender For supply of isolator assembly k3 on off , shunt trip assembly complete , no volt coil assy under voltage coil as , shunt trip coil , current transformer for ammeter , ammeter 100 5 for acb , limit switch 2no plus 2nc for breaker , overload assembly breaker 110a 200a , ammeter 200 5 for acb , busbar , push button actuator for el test , push button actuator for el reset , air circuit breaker with wiring and assy , power cable for 200a for breaker chamber , power cable for 200a for isolator chamber , ct for ol , dashpot oil per litre , brass terminal with insulator dmc , brass terminal with dmc insulator , brass terminal for cp , brass terminal for og , moving contact assembly for isolator , fixed contact assmbly for isolator300a , moving contact assembly for breaker 300a , fixed contact assembly for breaker 300a , ct with ammeter 0 400a ctr 300 5a type , ammeter 300 5 for acb , air circuit breaker with wiring assy , on off isolator 300a , earth leakage relay 50 750ma with time l , on delay timer , control relay 110v , aux contactor with coil , actuator no , miniature circuit breaker , restrained type plug and socket complete , on off rev isolator , indicating lamp with pcb mounting , ct for over load , single phasing preventor with module , copper terminal bushing cp og , terminal bushing assly with brass termin , rectifier , brass cone and gland assembly , glass fuse with holder , core balance transformer , potential transformer 80 va , brass stud with dmc bushing for og , auxiliary contactor220v ac , potential transformer , hrc power fuse , current transformer for o l 15va , thermal overload relay , under voltage relay 110v , isolator on off rev 100a , h t h r c p t fuse , fuse holder plus glass fuse , toggle switch , off delay timer , single pole two way toggle switch , annunciating led panel , 22 point 5 dia led indicator yellow , 30 point 5 mm dia push button red , 30 point 5 mm dia push button yellow
Tender For supply of supplying of 1.5 tr nominal capacity invertor type metal body , installation, testing and commissioning of of 1.5 tr inverter type ductable air cooled split ac unit as per item no.1 above in equipment room , providing and fixing heavt duty powder coated m s stand of suitable size made out of suitable guage ms shee , supply and fixing of 3 core 2.5 sq mm control cum transmission wiring and ac power supply cable of shielded copper conductor for looping between indoor and outdoor , supply and fixing of 4 core 1.5 sq mm control cum transmission wiring and ac power supply cable of shielded copper conductor for looping between indoor and outdoor , supply installation testing and commissioning including vaccumiazation and nitrogen testing of , supply installation testing and commissioning including vaccumiazation and nitrogen , supplying and fixing of 25 mm sizes of rigid upvc piping from outlet socket of ac unit complete with elbow , supplying and fixing dp sheet steel enclosure on surface or recess along with 25 or 32 a 230 v c curve dp mcb , supplying and fixing 5 amps to 32 amps rating, 240 or 415 volts c curve miniature circuit breaker suitable for inductive load of single pole and neutral , providing and fixing supply air grills of powder coated aluminum construction having a free area of not less than 70 percent without volume control dampers , supplying and installing of 150 mm width 50 mm depth 1.6 mm thickness nominal size of perforated hot dipped galvanised iron cable tray
Tender For tender for supply of dismantling of unserviceable air circuit breaker from lt panel by disconnecting all incoming and outgoing electrical connection and supply and fixing of air circuit breaker 4 pole 415 volts ac supply 800 amps 50 ka thermal magnetic release fixed type connecting all incoming and outgoing connection complete all as specified and directed make l and t cat part no uw108nff01800 legrand schneider 01 each , dismantling of unserviceable mccb by disconnecting all incoming and outgoing electrical connection and supply and fixing of mccb 4 pole 415 volts ac supply 320 amps 50 ka breaking capacity 50 hz with thermal magnetic release with spreader link on both side connecting all incoming and outgoing connection complete all as specified and directed make l and t cat part no du400n cm98404ooqo legrand schneider 01 each , supply laying and testing cable xlpe insulated screened pvc bedded galvanised steel strip or wire armoured electric power cables heavy duty 1100 volts grade with stranded aluminium conductor of size 240 sq mm 3 point 5 core complete all as specified and directed make gloster polycab wires pvt ltd grandlay plaza 80 rm , excavation in trenches not exceding 1 point 5 m wide and not exceding 1 point 5 m in depth and getting out soft loose soil complete all as specified and as directed for laying of under ground cable foundation of pole and stay etc complete all as specified and as directed 16 point 74 cum , returning filling in including spreading leveling watering and well ramming in layers not exceeding 25 cm thick in soft loose soil complete all as specified and directed 9 point 66 cum , removing excavated material not exceding 50 m and depositing where directed at a level not exceding 1 point 5 m above the starting point all as directed 7 point 08 cum , material and labour for providing sand cushioning with dry fine sand including filling spreading levelling in layers in cable trench with approved quality of sand for protection of under ground cable complete all as specified and directed 5 point 02 cum , supplying and laying burnt clay bricks sub class b old size laid in trenches over cable protection complete all as specified and directed 0 point 15 per 1000 nos , laying only serviceable bricks obtained from the items specified here in before that is during taking out of under ground cable laid flat dry in trenches with width of the bricks laid to the axis of cable for protection of cable complete all as specified and as directed 350 each , m and l for boring of holes horizontally under road pavement hard standing footpath blast wall without damaging the surface of road minimum 1 point 0 meter below the road surface with the help of gi tubing not exceding100mm bore for passing of underground cable complete all as specified and directed note gi pipe laid will be measured and paid separately under the respective items of schedule 10 rm , m and l for 80mm bore gi tubing light grade with all fittings laid across road or across pcc drains along electric pole or floor wall for cable protection complete all as specified and directed 10 rm