Tender For e-quotations are invited for ascertaining rate of items for preparing estimate of construction of weigh bridge and operator room, barhait - supply, installation, testing & commissioning of weighbridge. platform size 12.0 x 3.0 meter max. capacity 60 mt. type of platform fully welded modular type weighbridge main u-beam 300 mm x 140 mm - u beam (e 350 grade h t plate) cross support 16 mm thick plate between two main long beam top plate 8 mm top plate with anti-skid strips foundation frame 100 mm x 50 mm long frame with fully welded 350 mm x 350 mm x 16 mm plane plate border frame 100 mm x 50 mm - both side heavy duty frame with side wall mounting load cells ms plates 150 mm x 150 mm x 16 mm - load cell top & bottom plate joint & assembly main beam, cross support & top plate completely welded to each other. guide rail round pipe based side frame - 100 mm - both side fasteners as per required & is standard paint 2 coat of ant-corrosive primer and 2 coat enamel paint material all material will be is 2062 standard material list weighbridge platform structure- - 01 no. u-beam type modular orthotropic all material will be is 2062 grade painting : 2 coat primer with enamel paint all standard joint assembly, nut & bolts, foundation plates etc . european design u beam orthotropic design. virgin material branded moc value engineering modular design. heavy-duty load cell -06 nos. eagle multi ended share beam type load cell-34.5t each... pre-calibrated digital technology (no need to make calibrate scale) digital signal for long distance. special diagnostic feature unique data string, can not be copy or replace. in built lighting protection. inbuilt filters for noise reduction. load cell mounting assembly with inbuilt lightning & surge protection. suitable for sending signal over long distance. electronics digitizer (smart intelligent terminal system) -01 no. no need to use computer system for our smart terminal direct connect dot-matrix / laser* printer full graphical lcd display (130 x 40 mm). three step software calibration & smart calibration to correct small errors & accurate readings. inbuilt 200000 ~ 250000 memories storage facility. usb port for data entry and back up. usb interface facility for data backup in external memory stick (pen drive). vehicle vise data entry and report printing multi level password for security - dynamic (otp system) & regular password facility. all date entry show in single window external smps power supply for load cell & other system safety. auto sms facility. optional facility to send sms & email weighment records. junction box (summation box) -01 no. high protection junction box with gd tubes & built in surge & lightning protection water proof cable pg-9 gland (ip67 protected) external metal box with locking facility for extra load cell cable & junction box - 01 no. usb key board for weighment data entry - 01 no. ups with battery - 01 no. pc system - 01 no. laser printer - 01 no. ci test weight - 01 ton. jumbo display 50 mm - 01 no. e soft -weighbridge management software - 01 no. load cell cable (shielded) -junction box to digitizer 100 meter accessories (cable, connectors & data signal cable etc .) - 01 set. flexible conduct pipe 1 meter for each load cell (rat protection) power cable for digitizer rs 232 interfacing cable - 2 meter (communication with pc), add 18 % gst, add 1% labour cess
Tender For e-quotations are invited for ascertaining rate of items for preparing estimate of construction of weigh bridge and operator room, sahebganj - supply, installation, testing & commissioning of weighbridge. platform size 12.0 x 3.0 meter max. capacity 60 mt. type of platform fully welded modular type weighbridge main u-beam 300 mm x 140 mm - u beam (e 350 grade h t plate) cross support 16 mm thick plate between two main long beam top plate 8 mm top plate with anti-skid strips foundation frame 100 mm x 50 mm long frame with fully welded 350 mm x 350 mm x 16 mm plane plate border frame 100 mm x 50 mm - both side heavy duty frame with side wall mounting load cells ms plates 150 mm x 150 mm x 16 mm - load cell top & bottom plate joint & assembly main beam, cross support & top plate completely welded to each other. guide rail round pipe based side frame - 100 mm - both side fasteners as per required & is standard paint 2 coat of ant-corrosive primer and 2 coat enamel paint material all material will be is 2062 standard material list weighbridge platform structure- - 01 no. u-beam type modular orthotropic all material will be is 2062 grade painting : 2 coat primer with enamel paint all standard joint assembly, nut & bolts, foundation plates etc . european design u beam orthotropic design. virgin material branded moc value engineering modular design. heavy-duty load cell -06 nos. eagle multi ended share beam type load cell-34.5t each... pre-calibrated digital technology (no need to make calibrate scale) digital signal for long distance. special diagnostic feature unique data string, can not be copy or replace. in built lighting protection. inbuilt filters for noise reduction. load cell mounting assembly with inbuilt lightning & surge protection. suitable for sending signal over long distance. electronics digitizer (smart intelligent terminal system) -01 no. no need to use computer system for our smart terminal direct connect dot-matrix / laser* printer full graphical lcd display (130 x 40 mm). three step software calibration & smart calibration to correct small errors & accurate readings. inbuilt 200000 ~ 250000 memories storage facility. usb port for data entry and back up. usb interface facility for data backup in external memory stick (pen drive). vehicle vise data entry and report printing multi level password for security - dynamic (otp system) & regular password facility. all date entry show in single window external smps power supply for load cell & other system safety. auto sms facility. optional facility to send sms & email weighment records. junction box (summation box) -01 no. high protection junction box with gd tubes & built in surge & lightning protection water proof cable pg-9 gland (ip67 protected) external metal box with locking facility for extra load cell cable & junction box - 01 no. usb key board for weighment data entry - 01 no. ups with battery - 01 no. pc system - 01 no. laser printer - 01 no. ci test weight - 01 ton. jumbo display 50 mm - 01 no. e soft -weighbridge management software - 01 no. load cell cable (shielded) -junction box to digitizer 100 meter accessories (cable, connectors & data signal cable etc .) - 01 set. flexible conduct pipe 1 meter for each load cell (rat protection) power cable for digitizer rs 232 interfacing cable - 2 meter (communication with pc), add 18 % gst, add 1% labour cess
Tender For supply of refrigerator double door 400 ltr , ilr small with voltage stabilizer , deep freezer small with voltage stabilizer , cold boxes small , cold boxes large , vaccine carriers with 4 icepacks , digital thermometer , ice pack , adult weighing scale , baby weighing scale , height measuring scale stadiometer , laryngoscope and endotracheal intubation tubes neonatal , mucus extractor , feeding tubes for baby , sponge holding forceps , vulsellum uterine forceps , tenaculum uterine forceps , torch without batteries , bowl for antiseptic solution , ent head light for opd , ear specula , digital b. p. apparatus , stethoscope , nsv set , minilap kits , nebuliser , otoscope , delivery table with mattress , disposable normal delivery kit , iucd insertion kit , suction machine electric , suction machine foot operated , oxygen cylinder accessories , hemoglobin meter , haemoglobin strips , autoclave hp 2 drum , cusco vaginal speculum s, m, l 1 each , sims vaginal speculum single nd double ended each of small, medium and large size , anterior vaginal wall retractor , kidney tray , cheatles forceps , reagents of cyan meth haemoglobin method for hb estimation , uristix for urine albumin and sugar analysis , abo nd rh antibodies , koh solution for whiff test , grams lodine solution 125 ml , crystal violet stain , acetone ethanol decolourising solution , safranin stain solution 125 ml , ph test strips , rpr test kits for syphilis , h2s strip test kits for fecal contamination of drinking water , test kits for estimation of residual chlorine in drinking water using orthotoludine reagent , whole blood finger prick hiv rapid test and sti screening test each , colorimetre , test tubes , pipettes , glass rods , glass slides , cover slips , scissors all types , binocular microscope , thermometer clinical , hub cutter , two bucket system for liquid waste management , simple operation table ot table , instrument trolley , i v stand , shawdoless 0. t. light , kellys pad for labour and ot table , radiant infant warmer , phototherapy unit , tube, feeding, ch07, l40cm, ster, soft, non toxic pvc tube suitable for neonates and children , oxygen catheter 8 f, oxygen cylinder , examination table with foot step , wheel chair , stretcher trolley , bed side screen , bed side locker , semi fowler bed with mattress , drum with tap for storing water , bed sheets , pillows with covers , blankets , baby blankets , towels , 3 colour been set for waste management , coloured puncture proof bags , o. t. fogger machine fumigation , delivery instruments set , dressing drum medium , stainless steel tray , dressing trolley , suction pump foot operated , linen trolley , pulse oximeter , water cooler with purifier , all in one computer , free standing table , executives office table , providing and fixing vertical blinds of approved make shade , providing and arrangement of mid back , kitchen trolly , public seating chair , low height openable storage , full height steel storage , multiple compartment lockers , credestal , single bed , conference table , pedestal fan , tube light , buckets , mugs , lpg stove , drum with a tap for storing water , coat rack , writing tables with table sheets , plastic chairs for in patients attendants , armless chairs , full size steel almirah , inverter
Tender For supply of library books c c - horticultural crops , postharvest technology of horticultural crops , postharvest technology of horticultural crops vol 07 , postharvest anintroductionto the physiology and handling of fruitandvegetables , practical handbook of ddcby , practical manual of nursery management , practical manual on organic farming , practical plant biochemistry , principles and applications of soil microbiology , principles and practice of plant breeding , principles of agronomy , principles of applied entomology , principles of field crop production , principles of genetics , principles of insect morphology , principles of pestiside chemistry by s k handa , principles of plant breeding , principles of plant nutrition , principles of plant pathology , principles of seed technology , principles of soil chemistry , principles of vegetables breeding , production technology for fruit and plantation crops , production technology of tropical and sub tropical fruit crops , production technology of tropical and sub tropical fruits crops , production technology of under exploited vegetable crops , prokaryotic symbionts in plants , protected cultivation of vegetable crops , protected cultivation of vegetables crops , rajmohans wife , recent advances in life sciences proc xvazra intern conf , rhs colour charts 6th edition , rice pest management , rice white tip nematode , rice the queen of cereals , river of fire aag ka darya , sapiens a brief history of humankind , seed pathology 2 vol set , seed science and technology , soil acidity and liming , soil analysis , soil chemistry , soil chemistry a basicelements , soil microbiology ecology and biochemistry , soil micromorphology and soil classification , soil physical chemistry , soil plant and water analysis , soil sampling preparation and analysis , soil science , soil science an introduction , statistical methods ans biometrical technique in plant breeding , statistical methods for research workers , swamy compilation of ccs cca rules , swamys compilation of general finances rules and advances to central govt servants , swamys complete manual on establishment and adminstration , synthetic pesticides , system atic of fruit crops , systematic pomology vol 1 2 , tales from firozsha baag , tamas , teach yourself hindi , test book of soil physics by a k saha , test book of vegetables tubercrops and spices , text book of entomology , text book of farming systems , text book of fungi bacteria and viruses , text book of pedology concepts and applications , text books of plant nematology by upadhyay , text books of rural development entrepreneurship communication , textbook of agricultural meteorology , textbook of glaustas olericulture , textbook of introductory plant nematology , textbook of introductory plant nematology , textbook of vegetables tubercrops and spices , the avocado botany production and uses , the black book of speaking fluent english , the cassava mosaic virus disease , the completete chnology book on bio fertilizer and organic farming , the culture of vegetables and flowers from seeds and roots , the elements of plant virology basic concepts and practical class exercises , the essentials of agriculture , the financial expert , the first promise , the fruits kripa sankar , the god of small things , the guide , the hungry tide , the inheritance of loss , the insects structure and functions , the insects structure functions and biodiversity , the last bee keeper , the ministry of utmost happiness , the palace of illusions , the physiology of vegetable crops 2nd edition , the plant root and its environment , the private life of an indian prince , the shadow lines , the theory and practice ofthe dewey decimal //bid details 2 / 117 classification system , the white tiger , theory of cataloguing , thinking fast and slow , trace elements in soils and plants , transformational leadership and innovative behaviour , transforming agriculture transforming india 3 vol set , trans
Tender For corrigendum : purchase of equipments - purchase of equipment, 1. configuration design an 8-channel battery analyzer and its accessories 2. power 425 w3. voltage measuring range: 25 mv to 5 v, discharge minimum voltage: 0v or better, accuracy: 0.05% of fs4. current range: 0.5 ma to 6 a, accuracy: 0.05% of fs or better 5. power per channel output power: 30w, stability; +/- 0.1% of fs or better6. time rise time: 1ms (0~full range)7. frequency 10hz8. charge mode of operation: cc, cv, cccv, cp end conditions: voltage, current, relative time, capacity.9. discharge mode of operation: cc, cv, cp, cr, end conditions: voltage, current, test time, capacity, energy.10. pulse mode charge: cp mode, cc mode, discharge: cc mode, cp mode, min pulse width: 500ms, automated switch: automated switch from charge to discharge for each pulse end condition: voltage, relative time11. dcir support for the calculation of the point of the dcir12. cycle cycles: 1 65500 or better, steps: 250 or better, nested function: max three levels of loops13. protective function software, power-down data protection, user-defined safety (upper and lower) tolerance of current, voltage, and delay time14. channel features independent pairs of closed loops for the constant current source and constant-voltage source15. test reports and curves for analysis different types of curves created by software based on user definition. (voltage-time curve, current-time curve, capacity-voltage curve, loops times charge/discharge capacity curve, loops times charge/ discharge efficiency curve, etc.), data reports created by the software. comparison of the performance of the batteries tested in channels, both visually and statistically16. channels independent control17. ac input ac 220v 10% / 50hz 18. voltage and current testing sample 4 wire connecting 19. noise 85db20. data management mysql database21. communication means tcp/ip protocol22. data output excel, txt23. communication interface ethernet port24. number of channels per cabinet 825. accessories: 1. bi-potentiostat: electrochemical workstation or moduletechniques the system should be capable of running the rde / rrde technique simultaneously cyclic voltammetry (cv) with simulation/fitting programs linear sweep voltammetry (lsv) with stripping bulk electrolysis with coulometry (be) differential pulse voltammetry (dpv) with stripping normal pulse voltammetry (npv) with stripping tafel plot (tafel), potentiodynamic deactivation, pitting corrosion, corrosion rate, linear polarization, corrosion current, etc. multi-current steps (istep) amperometric i-t curve (i-t) lifetime testing open circuit potential time (ocpt) chrono amperometry (ca) chrono coulometry (cc) chronopotentiometry with current ramp (cpcr) potentiometric stripping analysis (psa) auxiliary signal measurement channel ir compensation external potential input galvanostatic charge discharge single/multiple cycle -chrono potentiometry (cp) with potential limits, polarity by potential or time, no. of cycles etc. voltage vs current density curves single or multiple potential steps with charge limits, single or multiple current steps, mixed voltage/current control using macro. i-v measurements, i max, pmax, fill factor, etc.impedance ac impedance (imp) 10 hz to 3mhz impedance time (impt) (mott-schottky) impedance potential (impe) impedance simulator with fitting open circuit potential time (ocpt)hardware specification of bi-potentiostat workstation/ module: potentiostat / galvanostat module, 2- or 3- or 4-electrode configuration maximum potential: 10v, maximum current: 250 ma peak or better and 2 amps with +/-25 volts for higher current measurement. compliance voltage: > 13v or better, potentiostat rise time: 300 ns or better galvanostat applied current range: 3na to +/- 100ma or better and upto 2 amps applied current accuracy: 20 pa or better input bias current: 1 pa or better cv and lsv scan rate: 0.000001 to 10,000 v/s. ca and cc pulse width: 0.0001 to 1000 sec imp freque
Tender For corrigendum : purchase of biomechanical equipments - nord board, it should be portable and should have 2 load cell sensors per unit with easy to attach hooks pivoting 360 degrees joint improving sensor accuracy it should have knee position indicator for replication of test position in each time. should have sample rate per sensor: upto 400hz, capacity per sensor: 100 kg/980-1000n safe over load per sensor: 150kg/1500n, max over load per sensor: 200kg/ 2000n, resolution: 1n and sensitivity: 22.0+/-mv/v. should have rechargeable battery & battery life should be100 active hours approx. should have working temperature range 5-40 c. (all weather proof) latest upgradable software should have both wired & wireless connectivity connectivity through usb (wired) bluetooth low energy (ble) for ipad & iphone i.e. (wireless connectivity) should provide 4 years warranty on hardware,should be provided with latest upgradable software and free software updates. should have software available in mobile & laptop (desktop) application with cloud analytics platform applications. should have ability to collect data both local i.e. laptop and on ios devices. local software:- for data collection & data analysis locally. cloud software:- for athlete data management and analysis. local (desktop /laptop) software should be compatible with windows 10 desktop applicationios 13 or later application (ipad & iphone). should have ability to collect data of over 10000 athletes or more to choose with simple name search / grouping them. cloud analytics platform for analysis. software (application) must give real time feedback of testing. license must be valid for 4years. cloud software: - should automatically sync all data collected on local mobile and laptop application when connected to internet.o should have a dashboard to see overview of organization s athletes data and different tiles(data indicators) to see athletes within and outside threshold zones. report section:- should have port section to able to compare different groups/athletes on longitudinal data. should have ability to compare same athlete s data over the period. athletes profile:- should have functionality to enter anthropometry (i.e. upper body & lower body measurement). athletes profile should be auto sync to local application and flexibility to move across different groups or teams with in organization and functionality to pick any athlete from large pool (1000 or more athlete). should be able to setup different access to different people i.e. to physiotherapist, sports scientist and s&c trainer within the organization to secure data access.api integration:- should have open-source api code for integration into athlete managementsystem to integrate in ams system. should have software license valid for 4years. wi-fi tablet 64gb, space grey-1year warranty (as provided by oem) - service by customer service of oem only.hsn:8471.training for installation and demonstration shall be provided at olympian balbir singh senior international hockey stadium, sector- 63, mohali, punjab., electromyography (open), the system should be supplied with minimum 16 high speed wireless emg channel with built in imu sensor. should have analog+ digital base station should have analogy output option to facilitate integration with third party hardware and software sensor should have fixed inter sensor delay of 0.5 milliseconds or less sensors should have fixed spacing between electrodes preferably less than 15 mm to avoid motion artifacts and cross-talk sensor contacts should be made up of a metal for better contact and better-quality signal should be supplied with a charging/transmitting station that communicates with sensors to get information on their charging, recording and signal strength sensors, sensor skin interface, cable, power adapter and accessories sensors facilitate emg and imu measurements emg data analysis software for stand-alone usage with live recording of at least
Tender For selection of a system integrator (si) to design, develop, supply, install, integrate, test, commission, operation and maintenance of an intelligent transport managementsystem (itms) on software as a service (saas) model for the capital region urban