Get complete information related to latest Surface Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Surface Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Surface Tenders.
Tender For supply and replacement of internal and external electrical installation at conference room, badminton room and other location in siri fort sports complex. - wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm frls pvc insulated copper conductor single core cable in surface / recessed medium class pvc conduit, with modular switch, modular plate, suitable gi box and earthing the pointwith 1.5 sq.mm frls pvc insulated copper conductor single core cable etc. as required. (i/c rebate of replaced item).a) group c (dsr-2022,1.10.3), wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm frls pvc insulated copper conductor single core cable in surface/ recessed pvc conduit, and earthing the point with 1.5 sq. mm f copper conductor single core cable etc. as required. (i/c rebate of replaced items)a) group c (dsr2022, 1.55.3), wiring for light/ power plug with 2x4 sq. mm frls pvc insulated copper conductor single core cable in surface/ recessed meduim class pvc conduit alongwith 1 no. 4 sq. mm frls pvc insulated copper conductor single core cable for loop earthing (i/c rebate of replaced items) as required. (dsr-2022,1.12), wiring for light/ power plug with 4x4 sq. mm frls pvc insulated copper conductor single core cable in surface/ recessed medium class pvc conduit alongwith 2 nos. 4 sq. mm frls pvc insulated copper conductor single core cable for loop earthing as required. (i/c rebate of replaced items)(dsr-2022,1.13), wiring for circuit/ submain wiring alongwith earth wire with the following sizes of frls pvc insulated copper conductor, singlecore cable in surface/ recessed medium class pvc conduit as required. (i/c rebate of replaced items)a) 2 x 1.5 sq. mm + 1 x 1.5 sq. mm earth wire (dsr-2022,1.14.1), b) 4 x 16 sq. mm + 2 x 6 sq. mm earth wire (dsr-2022,1.14.11), supplying and drawing following pair 0.5 mm dia frls pvc insulated annealed copper conductor, unarmored telephonecable in the existing surface/ recessed steel/ pvc conduit as required. (i/c rebate of replaced item). 1 pair (dsr-2022,1.18), supplying and fixing following size. modules. gi box along with modular base cover plate for modualr switches in recess etc. as reqd.(i/c rebate of replaced items) (a) 1 or 2 module (75mm x 75mm) (dsr-2022,1.27), supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. (i/c rebate of replaced items)a) telephone socket outlet (dsr-2022,1.24.6), supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. (i/c rebate ofreplaced items) (dsr-2022,1.25), supplying and fixing suitable size gi box with modular plate and cover in front on surface or in recess, including providing andfixing 3 pin 5/6 a modular socket outlet and 5/6 a modular switch, connections etc. as required. (i/c rebate of replaced items) (dsr2022,1.31), supplying and fixing suitable size gi box with modular plate and cover in front on surface or in recess, including providing andfixing 6 pin 5/6 & 15/16 a modular socket outlet and 15/16 a modular switch, connections etc. as required. (i/c rebate of replaceditems) (dsr-2022,1.32), supplying and fixing following way, horizontal type three pole and neutral, sheet steel, mcb distribution board, 415 v, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (but without mcb/rccb/isolator) (i/c rebate of replaced items) (dsr_2022)a) 4 way (4 + 12), double door, b) 6 way (4 + 18), double door, c) 8 way (4 + 24), double door, supplying and fixing 5 a to 32 a rating, 240/415 v, 10 ka, "c" curve, miniature circuit breaker suitable for inductive load of following poles in the ex
Tender For tcmc - construction of swd and culvert at bharathi nagar main road and cc surface at subramani koil street in ward no.14,15 tambaram city municipal corporation zone ii
Tender For construction of storm water drain and providing bt surface to sharma street via zion school to alwin school ward no 65 zone 5 in tambaram city municipal corporation.
Tender For supplying and fixing of electrical fitments for newly constructed toilet of d coy barrack and new jamin toilet at stc bsf of north bengal electrical installation - wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm frls pvc insulated copper conductor single core cable in surface/ recessed medium class pvc conduit, with piano type switch, phenolic laminated sheet, suitable size m.s. box and earthing the point with 1.5 sq.mm. frls pvc insulated copper conductor single core cable etc as required. group b, rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm frls pvc insulated copper conductor single core cable and 1.5 sq.mm. frls pvc insulated copper conductor single core cable as earth wire in existing surface/ recessed steel conduit including dismantling as required. group b, wiring for circuit/ submain wiring along with earth wire with the following sizes of frls pvc insulated copper conductor, single core cable in surface/ recessed medium class pvc conduit as required 2 x 1.5 sq. mm + 1 x 1.5 sq. mm earth wire., wiring for circuit/ submain wiring alongwith earth wire with the following sizes of frls pvc insulated copper conductor, single core cable in surface/ recessed medium class pvc conduit as required.2 x 4 sq. mm + 1 x 4 sq. mm earth wire. 2 x 4 sq. mm + 1 x 4 sq. mm earth wire., supplying and fixing 3 pin 5 amps ceiling rose on the existing junction box/ wooden block including connection etc. as required. 3 pin 5 amp, supplying and fixing metal box of 180mm x 100mm x 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 & 15/16 amps socket outlet and 15/16 amps piano type switch, connection, painting etc. as required. size : 180mm x 100mm x 60mm deep., supplying and fixing following way, single pole and neutral, sheet steel, mcb distribution board, 240 v, on surface/ recess,complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (but without mcb/rccb/isolator). 8 way , double door., supplying and fixing 5 a to 32 a rating, 240/415 v, 10 ka, "c"curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required. single pole., supplying and fixing 5 a to 32 a rating, 240/415 v, 10 ka, "c"curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required.single pole and neutralsingle pole and neutral., earthing with g.i. earth pipe of following size including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. 4.5 metre long, 40 mm dia ., supplying and laying following size g.i. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with gi thimble etc. as required.6 swg., supplying and fixing cable route marker with 10 cm x 10 cm x 5 mm thick g.i. plate with inscription there on, bolted /welded to 35 mm x 35 mm x 6 mm angle iron, 60 cm long and fixing the same in ground as required. standard make., add applicable rate of gst @18% in place of 12% (0.0633mf) on dsr item. s no.(1 to 12), add 1% labour cess on s no. (1 to 12) + s no.13, modified estimate cost after using correction factor on account of gst @ 0.973 on dsr items s no. (1 to 12) + s no.13 + s no.14, supplying and fixing 3 mm thick phenolic laminated sheet cover in front of ms switch box including making hole and al. alloy/ cadmium plated iron screws, 20 mm, washers etc. as required.hylem/formica/anchor/as approved by engg incharge., supplying and fixing of 6 watt surface type trim cosmo panel square shape led light suitable for 240 volt, single phase, 50
Tender For resurfacing of surface and patch work need basis inside bharat mandapam premises with dense bituminous concrete from gate no 10 to gate no 1 and various locations in old campus during 2025 26