Tender For supply of ureteric catheter open end 5 fr 70cm , ureteric catheter openend 6 fr 70 cm , digital flexible ureteroscope single use with digital cmos imager , pcnl drape set , cystoscopy , turp drape set , double j stent open end 5 fr 26 cm , double j stent open end 6 fr 26 cm , lohexol 300 mg per ml vial of 50ml inj , initial puncture needle 18 point 5g 2parts , zebra guide wire straight 0 point 035inch 145cm , pigtail catheter drainage set , suprapubic balloon catheter set 14fr , amplatz sheath 18fr with dilator , foley balloon catheter three way 24 fr , silicon double j sten set 6 fr 26cm , peracetic acid bott of 810gm , urostomy flange 35500 55mm base plate with pouch 55mm bag , guide wire with nitinol core hudrophilic coating 3cm flexible angled 0 point 035inch 150cm , guide wire with nitinol core hydrophilic coating 3cm flexible straight 0 point 035 inch 150cm , foleys balloon catheter 3way 22fr , 100 percent silicon foley catheter 2 way 14fr , foleys balloon catheter 20fr 3 way , skin stapler with 35 or 55 stainless staples , urostomy kit complete consisting of 10 flange plus 10 pouch plus 1 belt plus 1 powder , foleys balloon catheter 3 way 18fr
Tender For corrigendum : e-bid for rate contract cum supply and empanelment of surgical items - blood administration set / blood transfusion set sharp and easy piercing spike suitable for blood bags and standard blood containers transparent cylindrical drip chamber with filter.filter size should be 200+20 micrometer. 150 cm long smooth kink resistant tubing efficient roller clamp to control and adjust the transfusion rate as per is 9824 (part 3):1996, suction catheter, sterile. size: fg 5 (for use in respiratory tract) soft, kink resistant tubing rounded open tip with lateral eye colour coded universal funnel connector for safe connection to standard suction equipment length 50 cms (min.) as per is0 8836:2014, suction catheter, sterile. size: fg 6 (for use in respiratory tract) soft, kink resistant tubing rounded open tip with lateral eye colour coded universal funnel connector for safe connection to standard suction equipment length 50 cm (min.) as per is0 8836:2014, suction catheter, sterile. size: fg 8 (for use in respiratory tract) soft, kink resistant tubing rounded open tip with lateral eye colour coded universal funnel connector for safe connection to standard suction equipment length 50 cm (min.) as per is0 8836:2014, suction catheter, sterile.size: fg 10 (for use in respiratory tract) soft, kink resistant tubing rounded open tip with lateral eye colour coded universal funnel connector for safe connection to standard suction equipment length 50 cm (min.) as per is0 8836:2014, suction catheter, sterile. size: fg 12 (for use in respiratory tract) soft, kink resistant tubing rounded open tip with lateral eye colour coded universal funnel connector for safe connection to standard suction equipment length 50 cm (min.) as per is0 8836:2014, suction catheter, sterile. size: fg 14 (for use in respiratory tract) soft, kink resistant tubing rounded open tip with lateral eye colour coded universal funnel connector for safe connection to standard suction equipment. length 50 cm (min.) as per is0 8836:2014, suction catheter, sterile. size: fg 16 (for use in respiratory tract) soft, kink resistant tubing rounded open tip with lateral eye colour coded universal funnel connector for safe connection to standard suction equipment length 50 cm (min.) as per is0 8836:2014, suction catheter, sterile.size: fg 18 (for use in respiratory tract) soft, kink resistant tubing rounded open tip with lateral eye colour coded universal funnel connector for safe connection to standard suction equipment. length 50 cm (min.) as per is0 8836:2014, suction catheter, sterile. size: fg 20 (for use in respiratory tract) soft, kink resistant tubing rounded open tip with lateral eye colour coded universal funnel connector for safe connection to standard suction equipment. length 50 cm (min.). as per is0 8836:2014., suction catheter, sterile. size: fg 22 (for use in respiratory tract) soft, kink resistant tubing rounded open tip with lateral eye. colour coded universal funnel connector for safe connection to standard suction equipment. length 50 cm (min.). as per is0 8836:2014, sterile catheter, single use, for urinary drainage (foley balloon catheter), 2 way, size 8 fg made of silicone elastomer bonded with latex should have hard plastic valve smooth distal end with smooth eyes for atraumatic intubation. symmetrical foley balloon balloon capacity 3- 5 ml as per is 11497 color coding marking to identify size. length, wall thickness and balloon capacity should be mentioned as per is 11497. specification for b,c,d,e,f,g should be mentioned as per is 11497 for particular size, sterile catheter, single use, for urinary drainage (foley balloon catheter), 2 way, size10 fg made of silicone elastomer bonded with latex should have hard plastic valve smooth distal end with smooth eyes for atraumatic intubation. symmetrical foley balloon balloon capacity 3- 5 ml as per is 11497 color coding marking to identify size length, wall thickness and balloon capacity should be mentioned as p