Get complete information related to latest Suture Item Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Suture Item Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Suture Item Tenders.
Tender For corrigendum : e-bid for rate contract cum supply and empanelment of surgical and sutureitems(rate contract for the period ending on 31.12.2026)
Tender For corrigendum : e-bid for rate contract cum supply and empanelment of surgical and sutureitems - anti a blood grouping serum ip(anti a monoclonal serum) [225], anti b blood grouping serum ip(anti b mono clonal serum) [226], anti d(rh) blood grouping serum ip/anti d blood grouping serum ip [227], vdrl antigen (with +ve and -ve control) / rpr slide kit :- specification for rpr _rapid plasma regain) slide test for detection of regain antibodies in syphilis1. rapid plasma reagin test kit having non- treponemal cardiolipin antigen coated carbon particles used in the detection of regain antibodies in serum / plasma of suspected cases of syphilis by the flocculation reaction.2. the kit should be meant for qualitative and semi quantitative detection of regain antiboidies against the non-treponemal cardiolipin antigen.3. sensitivity & specificity should be 95% or more.4. positive & negative control serum should be provided with the kit for at least 10% of the tests in each kit.5. the kit should have shelf life of minimum 12 months or more at the time of delivery of consignment. the kit should be stored at 2 c - 8 c.6. adequate literature detailing the principle, components, methodologies, validity criteria. bio-safety, performance characteristics, storage conditions, limitation of assay, manufacture and expiry dates and methods of disposal should be provided with each kit.7. the test should be free from possible interferences with potentially cross reactive sera.8. all the test kits should be provided with necessary / required disposable accessories in sufficient quantity.9. the imported kit should have approval of the statutory authority in its country of origin . the imported kits should have been registered and licensed in india by the cdsco. (central drugs standard control organization), double blood bags with sagm (350ml)general specifications annexure- xvi and specification in annexure-xxiii, laproscopic knotless pga -pcl bidirectional taper point surgical suture self fixation device with autolock mechanism made up of pga -pcl bidirectional taper point 17 mm & 32cm, curved cutter stapler 40 mm linear cutter simultaneous cutting and stapling, aortic punch 4.5 length betwwen 6 to 7 midlength diamond edge sharp, dual cut edge for clean precise removal of aortic tissue, conical tip or round / eliptical tip for easy insertation by straight or button hole tech, should have long and short handle confirguaration, sterile packing, aortic punch 3.6 length betwwen 6 to 7 midlength diamond edge sharp, dual cut edge for clean precise removal of aortic tissue,conical tip or round / eliptical tip for easy insertation by straight or button hole tech, should have long and short handle confirguaration, sterile packing, biopsy gun with compatible co-axial needle 14g x 11cm to 20cm programmable automatic should have 20mm sample notch and thin wall cannula for larger core and echogenic making on both stylet tip and cannula for improved visibility during procedure. should have three programmable firing mode-automatic mode, delay mode and zero throw mode. should have two firing btton on surface of the gun, size 12g, 14g, 16g, 18g, 20g with length 11cm, 15cm, 20cm. should come with compatible coaxial packed with biopsy gun. usfda approved., programmable automatic biopsy gun with compatible co-axial needle size 18gx11cm or above should have 20mm sample notch and thin wall cannula for larger core and echogenic making on both stylet tip and cannula for improved visibility during procedure. should have three programmable firing mode-automatic mode, delay mode and zero throw mode. should have two firing btton on surface of the gun, size 12g, 14g, 16g, 18g, 20g with length 11cm, 15cm, 20cm. should come with compatible coaxial packed with biopsy gun. usfda approved. (size 18gx11cm or above), programmable automatic biopsy gun with compatible co-axial needle size 18gx15cm or above should have 20mm sample notch and thin wall cannula for larger core and
Tender For e-bid for rate contract cum supply and empanelment of surgical and sutureitems - dual rapid test kit for hiv & syphilis, synthetic absorbable wound closure device with dual cut barb with velded loop on end madeup with glycomer blue size 2-0, 1/2 circle, 24mm, 30-45cm rc size 2-0, linear cutter 55mm with six rows, 3d staple formation, option of closed staple height of 1.5mm/1.8mm/2mm in one cartridge only, linear cutter 75mm with six rows, 3d staple formation, option of closed staple height of 1.5mm/1.8mm/2mm in one cartridge only, universal linear cutter cartridge 75mm open linear cutter compatible with selectable staple height linear cutter 75mm.option of closed staple height of 1.5mm/1.8mm/2mm in one cartridge only. 6 rows 3-d staple technology., laparoscopic shears 5mm diameter,36cm long, 18mm curved coated blade and a clamp arm with tissue pad, capable of cutting,sealing,grasping and coagulating blood vessels up to and including 7mm in diameter, 360 degrees rotation, advance hemostasis hand activation mode for sealing vessels upto 7mm in diameter ,ergonomic handle compatible with ultrasonic energy source, capable of hand and foot activation with an integrated hand piece and transducer., aortic punch 4 length betwwen 6 to 7 midlength diamond edge sharp, dual cut edge for clean precise removal of aortic tissue, conical tip or round / eliptical tip for easy insertation by straight or button hole tech, should have long and short handle confirguaration, sterile packing, rem (return electrode monitoring) single use, corded patient return electrodes conductive adhesive hydrogel with usfda, offset connector cardio sensor electrodes it should have high conductive wet gel to ensure reliable traces. it should be design with offset connector to prevent artefacts from disrupting the readouts it should have high quality ag/agcl sensor to ensure excellent trace quality it should have size not more than 72 x 68 mmsize adult, over-the-ear nasal cannula 50 tubingover-the-ear nasal cannula with star lumen, 50 tubing, must be flexible contoured lip tab provides a high level of stability and patient comfort. over-the-ear design for a comfortable and secure fit, crush- and kink-resistant tubing. manufacturer must be us-fda registered & certified with en/eu iso 13485 & applicable 510k & ce certification., adult mask for tracheostomy adult mask for tracheostomy and laryngectomy aerosol therapy tubing connector must swivels 360 for ease of positioning; 22 mm od connector accepts 22 mm, corrugated tubing and nebulizer tees. manufacturer must be us-fda registered & certified with en/eu iso 13485 & applicable 510k & ce certification., pardiatric mask for tracheostomy pediatric mask for tracheostomy and laryngectomy aerosol therapy tubing connector must swivels 360 for ease of positioning; 22 mm od connector accepts 22 mm, corrugated tubing and nebulizer tees. manufacturer must be us-fda registered & certified with en/eu iso 13485 & applicable 510k & ce certification., adult conventional single water trap (non-heated) ventilator circuits are available in a variety of different configurations and styles.to incorporate standard connectors for use with a variety of ventilators, ported wyes allow pressure sensing and temperature monitoring and include tethered caps, all adult conventional circuits with 72 in. long, standard ventilator circuit with straight connector inspiratory limb water trap (for use with hmes only). manufacturer must be us-fda registered & certified with en/eu iso 13485 & applicable 510k & ce certification, adult ventilator circuit single water trap adult conventional single water trap (non-heated) ventilator circuits are available in a variety of different configurations and styles.to incorporate standard connectors for use with a variety of ventilators, ported wyes allow pressure sensing and temperature monitoring and include tethered caps, all adult conventional circuits with 72 i