Web Analytics Made Easy - StatCounter

Switch Fuse Unit Scrap Tenders

Get complete information related to latest Switch Fuse Unit Scrap Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Switch Fuse Unit Scrap Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Switch Fuse Unit Scrap Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

Central Government/Public Sector

CTN :45382837 Due date: 22 Jun, 202622 Jun, 2026 NA
Tender For repair/maint of external electric supply system, distribution lt panels with connected items and allied services at other than basistha area under ge guwahati. - excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr deep for taking out / laying of under ground cable, pole or stay and getting out in soft soil strata complete all as specified and as directed., returning filling in including spreading leveling watering and well ramming in layers not exceeding 25cms spread any type of soil complete all as specified and as directed., removing excavated materials not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and as directed., supply and lay for dry river sand filling for cable protection with a layer of 8cm deep before laying and 15cm covering above the top edge of cable after laying complete all as specified and as directed. (note : punned thickness shall be measured)., m&l for bricks common burnt clay, building brick, sub class b designation 75 old size bricks laid in trenches flat over sand cushioning for cable protection complete all as specified and as directed., m&l for supply and fixing / laying in replacement, connect, test and commissioning of lt under ground cable xlpe insulated, screened, pvc bedded, galvanised steel strip or wire armoured, electric cable (heavy duty) with multistranded aluminium conductor, 1100 volts grade in trenches/on wall/poles laid in ducts/inside protection pipe of the following cross sectional area including cable glands,lugs and suitable size of ms saddle clips (where ever cable laid in ceilings / walls without cable duct) complete all as specified and as directed.note : manufacturers test certificate shall be submitted alongwith rar/fb to engr-in-charge., (a) 95 sqmm x 3.5 core, (b) 70 sqmm x 3.5 core, (c) 50 sqmm x 3.5 core, (d) 25 sqmm x 3.5 core, supply and fixing in repair, connecting, testing and commissioning mccb in panel etc. mccb, tpn (4 pole), 630 amps, 50ka breaking capacity with overload and thermal tripping feature with magnetic release, 415volts ac, 50hz, icu = 100%, including certain addition or alteration if required at site complete all as specified and directed., supply and fixing in repair, connecting, testing and commissioning mccb in panel etc. mccb, tpn (4 pole), 400 amps, 36 ka breaking capacity with overload and thermal tripping feature with magnetic release, 415volts ac, 50hz, icu = 100%, including certain addition or alteration if required at site complete all as specified and directed., supply and fixing in repair, connecting, testing and commissioning mccb in panel etc. mccb, tpn (4 pole), 250amps, 36ka breaking capacity with overload and thermal tripping feature, 415volts ac, 50hz, icu = 100%, including certain addition or alteration if required at site complete all as specified and directed., supply and fixing in repair, connecting, testing and commissioning mccb in panel etc. mccb, tpn (4 pole), 160amps, 36ka breaking capacity with overload and thermal tripping feature, 415volts ac, 50hz, icu = 100%, including certain addition or alteration if required at site complete all as specified and directed., supply and fixing in repair, connecting, testing and commissioning mccb in panel etc. mccb, tpn (4 pole), 125 amps, 36ka breaking capacity with overload and thermal tripping feature, 415volts ac, 50hz, icu = 100%, including certain addition or alteration if required at site complete all as specified and directed., supply and fixing in repair, connecting, testing and commissioning mccb in panel etc. mccb, 4 pole, 100amps, 26ka breaking capacity with overload and thermal tripping feature, 415volts ac, 50hz, icu = 100%, including certain addition or alteration if required at site complete all as specified and directed., supply and fixing in repair, connecting, testing and commissioning mccb in panel etc. mccb, 4 pole, 63amps, 16 ka breaking capacity with

Central Government/Public Sector

CTN :45208709 Due date: 08 Jun, 202608 Jun, 2026 22.10 Lacs
Tender For corrigendum : special repair and replacement of mccb, db, earthing, bus bar panel and other e/m electrical supply related wks at ge (a) ahmedabad

Central Government/Public Sector

CTN :44978162 Due date: 11 Jun, 202611 Jun, 2026 9.50 Lacs
Tender For corrigendum : repair/maint of lt distribution network system, various size cables busbar, panels, mccb and allied works at offrs enclave and tmq area and offrs mess under age (i) manauri

Central Government/Public Sector

CTN :45322496 Due date: 22 Jun, 202622 Jun, 2026 1.41 Crore
Tender For special repair and replacement of sub main wiring, mccb, mcb and db at certain md accn at ats belagavi

State Government

CTN :45313570 Due date: 09 Jun, 202609 Jun, 2026 NA
Tender For e-quotation for seeking firm rates for non-schedule items for preparing estimates. - s/i/t/c of new 80 hp vt pump set, supplying,installation,testing and commissioning of vt pumpset (confirming to is1710:2021 standards) with 35 ft suitable size ms column pipe assembly in random length of 5 ft.(make-jyoti/wpil/kirloskar) with ss/bronze impeller capable to discharge 216 m3/h against a total head of 68m coupled with vertical solid shaft tefc ie3,ip55 type squirrel cage induction motor (make-siemens/crompton/abb) operating on 3 phase 50 hz,415v+- 10% supply and having speed 1400-1500 rpm (bhp of motor should be 10% more than that of pumpset including cost pof supplying,fitting and fixing of all required accessories, repairing of 80 hp vt pump set at raw water, supplying all labour tools and tackles for taking out the 40hp vt pump set with bowl assembly, column pipe and line shaft etc., cost towards dismantling of complete bowl assembly., cost towards repairing and fitting the parts of vt pumpset as per requirement (works as complete overhauling of the pump) such as:-1.machining/lathe work 2.changing ss top shaft,line shaft(2 nos of 5 feet) of and bottom shaft2.repairing of bowl assembly and impleller3.supplying and fitting c.l spider bearing with rubber cut less bush-4nos4.supplying and fitting of worn-out nut-bolts,bolt-nut washer,gland body bush machining,other machining works,etc as per requirement, complete assembling the pump set and lowering including supplying all petty materials., cost for supplying and installation of required accesories for repair and maintenance of motor control panel such as:-150 amp contactor-2 no (for 1 no starter)160 amp,breaking capacity -36ka mccb 1 no56-90 a electronic overload relay-2 nostimer-2 nosvolt meter 1 nosamp motor 1 nospilot lamp 6 nosselector switch 4 nossingle phase preventer 2 nos[ all accessories of reputed make]with complete internal wiring with suitable size of copper wire and testing on load., repairing of 30hp c/f pump sets at clear water, cost for dismantling of 30 hp c/f and pump inspection,changing of its damaged parts such as:-key-01 no, gland tightner -1 set, gland tightner stud-2 nos, c.i bearing housing with cap -1 set, ball bearing 6306 (skf)-2 nos, grease, gland packing,maching of the pump parts as per required etc all complete and testing on load etc., cost towards complete repairing of motor control panel starter 30hp cf pump set opening and changing of damaged parts such as 1.mccb - 50 amp,25ka,3pole-2 nos (for motor backup protection),mccb -100 amp,50ka,3pole-1 no (main mccb)2.overload relay 26-40 amp-1no3.star delta timer-1no4.digital volt meter,ampere meter,three pahse indicator lamp,push button on/off,on/off/trip indicator,wiring,etc as per required, repairing of 15hp c/f pump sets at clear water, cost for dismantling of 15hp c/f and pump inspection,changing of its damaged parts such as:-key-01 no, gland tightner -1 set, gland tightner stud-2 nos, c.i bearing housing with cap -1 set, ball bearing 6306 (skf)-2 nos, grease, gland packing,maching of the pump parts as per required etc all complete and testing on load etc., cost towards complete repairing of motor control panel starter 30hp cf pump set opening and changing of damaged parts such as 1.mccb -25 amp,15ka,3pole-2 nos (for motor backup protection),mccb -50 amp,25ka,3pole-1 no (main mccb)2.overload relay 20-25 amp-1no3.star delta timer-1no4.digital volt meter,ampere meter,three pahse indicator lamp,push button on/off,on/off/trip indicator,wiring,etc as per required

Central Government/Public Sector

CTN :45316431 Due date: 15 Jun, 202615 Jun, 2026 21.00 Lacs
Tender For ca no. cwe/hills/rkt/40 of 2026-2027 repair/ replacement of mccb, lt overhead / ug line and ht overhead vcb, acb, god etc. at haldwani, ranibagh, kamola, kathgodam and nainital stn under ge ranikhet

Central Government/Public Sector

CTN :45304113 Due date: 13 Jun, 202613 Jun, 2026 25.00 Lacs
Tender For repair maint of old unsv meter panel meter box sub main wiring electric distribution board mccb mcb and other connected items under ge mis mhow

Central Government/Public Sector

CTN :45294562 Due date: 05 Jun, 202605 Jun, 2026 49.00 Lacs
Tender For repair/ replacement of lt over haed line, lt panel, mccb, acsr conductor, lt pole, lt ug cable and connected accessories at vijay line, power house area ttse, eme, ae regt btr, ac depot, kk range and stn units under ge(n) ahilyanagar

CTN :45159066 Due date: 11 Jun, 202611 Jun, 2026 33.89 Lacs
Tender For supply of electrical materials for the repair and maintenance of street light as per the boq - details, t-5 power/energy saver 2x24w choke, t-5 power/energy saver 24w ftl tuberod, 2x24 t5-holder, t5 power saver 2x24 fixture acrylic transparent cover, t5 power saver 4x24 fixture acrylic transparent cover, 150w hpsv choke, 150w hpsv lamp, capacitor 33mfd 250vac 50 hz, electronic ignitor suitable for 150w hpsv lamps, 150w holder (porcelain), led driver 50w bis certified, led mcpcb plate 60w, led mcpcb plate 50w, led mcpcb plate 150w, supplyingof isi marked and approved make of moulded case circuit breaker(mccb) suitable for 3phase,3pole,50hz,415 volts, ac supply with respective interrupting capacity(ka) at 415 volts cited against their range standard conforming to is - 8828: 8.1mccb with breaking capacity 25 ka at 415 v: current rating -125 amps & 70% -100% adjustable, supply of sovp device should have single high capacity varistor in the l-n plug and encapsulated spark gap for n-pe, l-n sovp should have a rated voltage of minimum 320v ac to handle indian power supply conditions. sovp should have visual indication on replaceable varistor and spark gap modules as well as a potential free contact on the socket for remote indication. sovp device should be wired up as per tt configuration of wiring in accordance with en 61643-11 standards. both the l-n and n-pe, spds should be rated for handling 30ka of nominal 8/20 s surge current.: sovp for pole light sub feeder panels - type 2 pluggable spd 3+1, rating l-n/n-pe uc 255/320 v in 30/60ka ka, lmax 30ka/60 ka, up 1.5kv, supplying of isi marked and accepted standard of miniature circuit breaker(mcb)ofcseries suitable for 240/415volts,50cycle,10ka value ac supply confirming to is:8828:1996,iec:60898 :2002 but without enclosures: single pole 63 amp., astronomical timer with dst feature, contactor 3 pole 90 amp 50hz 415volts with no-nc contacts, tpn connector 150a, supply of approved make powder coated sheet steel encloser spn mcb db inclusive of busbar,neutral bar,earth bar & two earth terminals etc. complete as per is:13032 (exclusive of mcb & isolator): 8 way double door, supply of sovp device should have single high capacity varistor in the l-n plug and encapsulated spark gap for n-pe, l-n sovp should have a rated voltage of minimum 320v ac to handle indian power supply conditions. sovp should have visual indication on replaceable varistor and spark gap modules as well as a potential free contact on the socket for remote indication. sovp device should be wired up as per tt configuration of wiring in accordance with en 61643-11 standards. both the l-n and n-pe, spds should be rated for handling 30ka of nominal 8/20 s surge current.: sovp for pole light - type 2 pluggable spd 1+1, rating l-n/n- pe uc 230/400 v in 5 ka, imax 10 ka, up 1.2kv, led batten tubelight 20w, supplying of approved make tpn mcbdb metal double door with provision for fpmcb/isolator/rccb/rcbo as incomer and sp mcbs as outgoing inclusive of busbar,neutral bar,earth bar & two earth terminals etc. complete as per is:13032 (exclusive of mcb & isolator ): 8 way (8+24), 8 sq.mm multistrand pvc insulated copper wire bundle 90mtr, 1.sq.mm aluminium single core wire bundle of 100mtr. isi marked, xlpe insulated power cable( conforming is-7098 part-1) 1100 volt grade 2-core isi marked with alu. stranded/solid conductor: 16 sq.mm unarmoured, xlpe insulated power cable( conforming is-7098 part-1) 1100 volt grade 4-core isi marked with alu. stranded/solid conductor: 16 sq.mm unarmoured, xlpe insulated power cable( conforming is-7098 part-1) 1100 volt grade 1-core isi marked with alu. stranded/solid conductor: 25sq.mm unarmoured, wooden ladder 21ft, toolkit set consisting of different sizes l-keys, screw drivers, testers and plier set., taperoll box consisting of 30pcs (conforms to is: 7809 (part 3, sec 1),self extinguishing,protects from electrolytic corrosion,excellent water resistance,suitable for primary ins

CTN :45203468 Due date: 06 Jun, 202606 Jun, 2026 5.00 Lacs
Tender For supply of electrical repair materials tender at jiwaji university, gwalior - led tubelight 20 watt. (havells. ,philipps , bajaj, syska), led tubelight 36-40 watt. (havells. ,philipps , bajaj, syska), led. street light 90-110 watt. (havells,bajaj, crompton), led. street light chock/ driver 90-110 watt. (havells bajaj, crompton), led. panel 2 x2 36 watt.(recessed mounting) (syska, bajaj, phillips, havells), led. panel 2 x2 45-50 watt.(recessed mounting) (syska, bajaj, phillips, havells), led. panel 2 x2 36 watt.(surface mounting) (syska, bajaj, phillips, havells), led. chock for panel 2 x2 36 watt. (syska, bajaj, phillips, havells), led flood light 90-100 watt. (syska, bajaj, phillips, havells), led flood light 200 watt. white (syska, bajaj, phillips, havells), led flood light 200 watt. worm white (syska, bajaj, phillips, havells), led. bulb 5 watt colours (syska, bajaj, phillips, surya), led. bulb 9 watt (syska, bajaj, phillips, surya), led. bulb 18-20 watt (syska, bajaj, phillips, surya), led. bulb 45-50 watt (syska, bajaj, phillips ,surya), unarmoured cable 2 core 10 sq.mm (havells, kei, rr kabel), armoured cable 2 core 10 sq.mm (havells, kei rr kabel), copper submersible flate cable 3 core 4 sq.mm. (havells, kei, finolex), copper submersible flate cable 3 core 6 sq.mm. (havells, kei, finolex), mcb. 6-32 amp c series (havells, legrand, l&t ), mcb. 6-32 amp d series (havells, legrand, l&t ), mcb. 63 amp. c series (havells, legrand, l&t ), mcb. 63 amp. d series (havells, legrand, l&t ), mcb box metal (2 way single door), mcb box pvc (2 way single door), mcb box pvc (4 way double door), tp. 63 amp. (havells, legrand, l&t ), tpn. 63 amp. (havells, legrand, l&t ), spn. 63 amp. (havells, legrand, l&t ), spn. 32 amp. (havells, legrand, l&t ), dp. 32-40 amp. (havells, legrand, l&t ), dp. 50-63 amp. (havells, legrand, l&t ), change over 200 amp. knife type (havells, hpl, bentex ), busbar 200 amp. g.i.(havells, hpl, bentex ), mccb 3p.100 amp, (l&t, havells ), mccb 3p.200 amp, (l&t, havells ), mccb 3p.250 amp, (l&t, havells ), mccb 3p. 400 amp. (l&t, havells ), lugs (alluminium) ring/pin/four type 35 sq. mm, lugs (alluminium) ring/pin/four type 50 sq. mm, lugs (alluminium) ring/pin/four type 70 sq. mm, lugs (alluminium) ring/pin/four type 95 sq. mm, lugs (alluminium) ring/pin/four type 120 sq. mm, lugs (alluminium) ring/pin/four type 150 sq. mm, lugs (alluminium) ring/pin/four type 240 sq. mm, lugs (alluminium) ring/pin/four type 400 sq. mm, mccb box metel for 100 amp., mccb box metel for 200 amp., mccb box metel for 250 amp., mccb box metel for 400 amp., copper flexible wire 14/76 (finolex, havells, kei), copper flexible wire 40/76 (finolex, havells, kei.), copper flexible 3 core cable 2.5 sq.mm finolex, havells, kei.), copper flexible 3 core cable 4.00 sq.mm finolex, havells, kei.), pvc insulated copper wire 1 sq. m.m.white colour (finolex,polycab, r.r.), pvc insulated copper wire 1.5 sq. m.m. (finolex, havells, r.r.), pvc insulated copper wire 2.5 sq. mm. (finolex, havells, r.r.), pvc insulated copper wire 4.0 sq. mm. (finolex, havells, r.r.), pvc. gen box 2 way (anchor, topson, pressfit ), pvc. gen box 3 way (anchor, topson, pressfit ), pvc. gen box 4 way (anchor, topson, pressfit ), pvc. gen box 8 way (anchor, topson, pressfit ), modular pvc box (surface) 2 module with base & cover plate complete. (anchor, topson, pressfit ), modular pvc box (surface) 3 module with base & cover plate complete. (anchor, topson, pressfit ), modular pvc box (surface) 4 module with base & cover plate complete. (anchor, topson, pressfit ), modular pvc box (surface) 6 module with base & cover plate complete. (anchor, topson, pressfit ), modular pvc box (surface) 8 module with base & cover plate complete. (anchor, topson, pressfit ), modular pvc box (surface) 12 module with base & cover plate complete. (anchor, topson, pressfit ), modular pvc box (surface) 18 module with base
 Loading, Please wait...

Connect us via What's Up