Get complete information related to latest Switching Cubical Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Switching Cubical Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Switching Cubical Tenders.
Tender For supply, delivery, fixing testig and trial run of 20 hp inline booster for 150 mm dia distrubution line along with new 415 volts 50 hz control switch gear panel board for operationg above pump set, ms chamber, ms suction, delivery connections at chainna golkonda to supply water to bahadurguda and lakshmi tanda villages and also provide extra water to fulfill the supplies udner shamshabad section, eam cell iv, operation and maintenance division-xviii manikonda
Tender For supply of control transformer, 200va, 750/415v, type-ii, 50hz, single phase, "h" class insulation, dry type & air cooled, along with fuses complete, suitable for use in switch board cabinets of eog/hog lhb type ac coaches, powers cars, lhb garib rath ac coaches & smart lhb hog ac coaches, confirming to rdso specification no. rdso/pe/spec/ac/0203/-2020 (rev-0). make as per letter. no. el/7.1.108/sbc/main file dt: 16.04.2021 are bhasin packard, nacei, trolex, ramyaa, trinitron, kontact consortium, abrol or ask powertec only.. [ warranty period: 30 months after the date of delivery ]
Tender For instant water heater (geyser) in capacity of 1 liter horizontal wall mounting. abs outer body,inner tank stainless steels power supply 230 volts ac, 50 hz, power consumption 3.0-4.5 kw. length of flexible cable two meter with 3 pin plugs of 16 amps. safety features heating element insulation incoloy glass coated safety device/thermostat/auto temperature control, safety value pressure value flow switch, temperature indication/display test report along with an offer from central govt. accredited labs nabl/ilac. conforming to is: 8978 latest and is: 302-2-35 (specification for safety of house hold and similar electrical appliance, part-2, section-35). make:- bajaj, recold, havells or similar. [ warranty period: 30 months after thedate of delivery ]
Tender For bi-annual up keeping, housekeeping & cleaning work in control room building, office, store & switchyard area with grass cutting & removing as well as anti-weed treatment in switch yard at 220 kv vartej substation of am division vartej under circle office amreli
Tender For providing of repair, maintenance, and installation of plant/ systems/equipments (version 2) - icgs c 423; l 006 during boat davit operations smoke observed from control transformer in control panel; service provider,repair, maintenance, and installation of plant/ systems/equipments (version 2) - icgs c 423; l 013 port blower of water jet compartment is not getting start zero insulation measured suspectd winding burnt; service provider,repair, maintenance, and installation of plant/ systems/equipments (version 2) - icgs c 423; l 022 contactor coil switch burn out; service provider,repair, maintenance, and installation of plant/ systems/equipments (version 2) - icgs c 423; l 023 defect rectification of maine engine charger; service provider
Tender For corrigendum : supply of ip based 5 mp dome network camera with 128gb sd card , ip based 5 mp bullet network camera with 128gb sd card , 16 channel nvr with 4k support and three numbers of 10tb hdds , 24 inch led monitor for nvr , client pc with 32 inch led monitor , 1kva offline ups , enterprise grade network switch poe 24 port gigabit, 4 sfp ports , cat6 stp outdoor cable bundles 305 meters each bundle , biometric finger print, card and pin based access control device , exit switch. , em lock. , high frequency hid proximity pvc access card , laptop for maintenance , 25 mm dia, 16 swg isi marked pvc conduit with accessories , power supply db box and mcb with accessories , pvc casing and capping 1 inch and 2 inch, 100 meters each , installation, laying, testing and commissioning of above items to the scctv and access control system as per specifications
Tender For corrigendum : supply of contactor for 60kva transformer, rated current : 95 a, rated voltage : 690v ac, main pole : 4, aux. contact : 1no+1nc, control voltage : 230v ac (168v ac-300v ac means 230v ac +/- 30%) with surge suppressor conforming to rdso specification no. rdso/pe/spec/ac/0184-2015 (rev.1) suitable for switch board cabinet (sbc) of lhb eog/hog type ac coaches. approved make & model : abb (af 116b-40) / schneider (lc1d1150046m5+la4da2u / c&s electric (lc1fdp1154u5+la9f980 (br). [ warranty period: 30 months after the date of delivery ]
Tender For tender for supply of radiation resistant cctv camera : : - type-ii (color ccd/cmos , 100m rad) radiation resistant camera head along with radiation resistant pan & tilt unit and mounting brackets. as per attached annexure-1 , corrigendum annexure-2 and annexure-3. , cabling system to transmit signals form vault cameras to ccu system which includes camera to ccu radiation resistant composite cable of 300 meters with 6 sets of cable connectors and applicable power cables as per annexure-1 , corrigendum annexure-2 and annexure-3. , field camera control unit and its racking system which includes 2 no. of camera control unit sub rack & 6 sets of camera control unit (ccu) cards (3 to be installed in field and 3 to be kept as spare for future ) as per annexure-1 , corrigendum annexure-2 and annexure-3 or equivalent sub rack system as per annexure-1 , corrigendum annexure-2 and annexure-3. , setup to convert ccu signals to optical signals which should include 3 no. of fiber optic transmitter and receiver set (capable of 4 camera system) and 6 no. of fiber patch cords , single mode , simpex and 3 no. of light interface unit 12 port , as per annexure-1 , corrigendum annexure-2 and annexure-3. , type-vi (color ccd/cmos sensor , non rr auto dome camera) with mounting brackets as per annexure-1 , corrigendum annexure-2 and annexure-3. , mechanism to transmit signal from non radiation resistant camera including , poe power supply for non-rr ptz camera (6 no.) field jb /rack in ss material for non-rr ptz camera (2 no.) liu 6 port , din rail mountable for non radiation resistant ptz camera (3 no.) din rail 8 port un-managed network switches (3 no.). 4 no. of fiber patch cords , single mode , duplex for non-radiation resistant ptz camera or equivalent as per annexure-1 , corrigendum annexure-2 and annexure-3. , mechanism for receiving signal at control room including light interface unit 24 port , rack mount (2 no.) and network video encoder (minimum 16-channel) along with accessories for intra-panel connections (2 no.) and 24 port un-managed network switches or equivalent (2 no.) , 4 no. of fiber patch cords , single mode , duplex as per annexure-1 , corrigendum annexure-2 and annexure-3. , recording and monitoring pc as per annexure-1 , corrigendum annexure-2 and annexure-3. , joystick suitable for mounting on control room panel cutout as per panel drawing as per annexure-1 , corrigendum annexure-2 and annexure-3. , 21 inch led backlit led color monitor as per annexure-1 , corrigendum annexure-2 and annexure-3. , video monitoring software setup as per annexure-1 , corrigendum annexure-2 and annexure-3 for minimum 9 camera. , mobile dolly consisting of camera control unit (ccu) , encoder , switch , joystick , engineering laptop with 15-inch to 17-inch screen , video management software for one camera , connection cables etc and their cabling as per annexure-1 , corrigendum annexure-2 and annexure-3. , control panel/rack 42u/ 27u setup for racking all instruments of cctv at control room as per annexure-1 , corrigendum annexure-2 and annexure-3. , cabling network optical fiber cable (6 core armored cable)-2000 meters twisted pair cable , rs485 , signal cable -200 meters unarmored coaxial cable rg59 -200 meters ethernet cable , cat-6 utp cable -610 meters video connector set -10 meters ethernet connectors rj-45 100 pieces conduit for cables 800 meters and other separate cables/ power cables/accessories required during installation one set of tool tackles for assembly/ disassembly/ of radiation resistant camera head viz. allen keys , lubricants , cable ties , loctite , heat sink , blank caps etc. 2 no. of control panel/rack size 27u setup for racking all instruments of cctv at field as per annexure-1 , corrigendum annexure-2 and annexure-3. as per annexure-1 , corrigendum annexure-2 and annexure-3 . , site installation & commissioning as per annexure-1 , corrigendum annexure-2 and annexure-3. , spare radiation resistance camera head s