Get complete information related to latest Tan Delta Test Set Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Tan Delta Test Set Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Tan Delta Test Set Tenders.
Tender For tender for supply of a non distructive test on steel members i dpt test , ii ut ultrasonic thickness gauge , iii sagging defection test total station , iv to check verticality of column , 1 b non distructive test on concrete members visual inspection as per specified in specification of documents , site testing charges concrete 2 upv testas per specified in specification of documents , 3 rebound hammer test schmidt s rebound hammer test for determining the concrete compressive test ref is 13311 part 2 , 4 half cell potential accordance in with astm c876 half cell potential to assess the probability of corrosion of reinforcement sac code 998346 , 5 carbonation in accordance with bs 1881 201 1986 clause 2 22 carbonation test to measure extent of carbonation from the concrete surface sac code 998346 , 6 profomete scan test on rcc members to assesss covers spacing of bars including approximate diameter bar , 7 core test core cutting and compression test for rcc structure in accordance with js 516 on rcc members. 70mm core cutting in reinforcement concrete core filling by specialized epoxy material micro concreate with bond coat , 8 preparing detail report per specified in specification of documents
Tender For bid to ras structural audit of building - visual inspection and photography performing a visual survey of the building and recording maping on drawing to assess extent of spelled concrete cracked concrete as per specification of document , ultrasonic pulse velocity test for rcc structure in accordance with is 13311 part 1 1992 by portable ultrasonic non destructive digital testas per specification of document , rebound hammer test rebound hammer test in accordance with is 13311 part 2 1992 by portable rebound hammer equipment at strategic locations , core test core cutting and compression test for rcc structure in accordance with is 516 on rcc members 70 mm core cutting in reinforcement concrete core filling by speialized epoxy material micro concrete with bond coat at strategic locations , reinforcement mapping reinforcement mapping test on rcc members to assess covers spacing of bars including approximate diameter at strategic locations , chemical test for rcc structure in accordance with is 456 2000 using ready made kits and reagents sample collected will be from half cell carbonation powderas per specification of document , half cell potential test for rcc structure in accordance with astm c876 half cell potential to assess the probability of corrosion of reinforcement at strategic locations , carbonation test for rcc structure in accordance with bs 1881 201 1986 clause 2 22 corbonation test to measure extent of carbonation from the concrete surface at strategic locations , to check and confirm present status of structure on basis on ndt results and visual inspection , to provide recommendation for structrue repairs and technical specification preparing bill of quantities for the repair etc all as specified and directed , vetting of report from government engineering college
Tender For corrigendum : supply of copper strip corrosion test apparatus and others - copper strip corrosion test bath , digital refractometer , gas cylinder for gc nitorogen , gas cylinder for gc hydrogen , gas cylinder for gc high purity air cylinder
Tender For anti wear type hydraulic oil as per is 8406(latest amendment)to the following specificati ons.(1)grade: vg 680.(2)kinematic viscosity at 40 deg cent,cst:612 to 728.(3)viscosity index (min):85 (4)pour point ,c,max:0.(5)flash point,cleveland open cup,c min:230(6) demulsibility:cuff after centrifu ging,mi,max:2.o.(7) demulsisbility:total free water collect- d during test(starting with 90 mi of water ),min:70.(8)demulsibility:(for r and o type)percent water m oil after 5-hour test,max:0.5.(9) timken e p test ok load,min:27kg.(10)oxidation stability @ 121 degree c,312h,10 litres air/h: increase in kinme tic viscosity at 100 deg c not exceed 6 percent.(11)ash,percent by mass.max:0.1.(12)air release value ,90 deg c minutes,max:20(13)copper strip corrosion for 3 houra at 100 degree c:not worse than 1.(14 )four ball wear test at 20kg load,wear scar diameter,mm,max:0.35.(15)fzg-niemann ep test,pass loa d stage,min:11th. make & model:(a)m/s.ioc: servo mesh sp 680.(b)m/s.bpc:bharat amocom 680.(c) m/s.hpcl:parthan ep 680.(d)m/s.balmer lawrie:protomac sp 680.(e)m/s.ibp:ibp mesh 680.(f)m/s.castr ol:alpha sp 680.or substantially equivalent. note:(1)the oil shall be supplied in only 210 litres metallic barrels only.(2)test certificate should be supplied along with the material supply.(3)oem or authorized dealers/agents having the valid authorized dealership document and same shall be provided while qu oting and also with the material supply.(5)the offer other than mentioned make and brands shall give the detailed test report as specified in the item description from nabl accreditation labs only. ]
Tender For non-destruction test on concrete members visual inspection visual inspection and photography performing a visual survey of the shed steel structure as per specified in specification of documents , site testing charges concrete upv test ultra sonic pulse velocity test upv test in accordance with as per specified in specification of documents , rebound hammer test schmidt rebound hammer test for determining the concrete compressive test , half cell potential accordance in with astm c876 half cell potential to assess the probability of corrosion of reinforcement sac code 98346 , carbonation in accordance with bs 1881 201 1986 clause 2 22 carbonation test to measure extent of carbonation from the concrete surface sac code 998346 , profometer scan test on rcc members to assesss covers spacing of bars including approximate diameter bar , core test core cutting and compression test for rcc structure in accordance as per specified in specification of documents , preparing detail report as per specified in specification of documents
Tender For tender for supply of taking down of light fittings of any type size and model complete all as specified and directed. , taking down of brackets of any type size and model complete all as specified and directed. , m& l in repair steel tubular swaged poles complete with cast iron base plate , finial taper plug , bolts , nuts & screws as specified type 410 sp 22 (8.5 metres long) complete all as specified & directed. , m& l in repair steel tubular swaged poles complete with cast iron base plate , finial taper plug , bolts , nuts & screws as specified type 410 sp 31 (9 metres long) complete all as specified & directed. , re fixing of led street light fittings of any wattage outdoor type complete all as specified and directed. , supply and fixing in repair led street light fitting 120 watt 230 v ac outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver , lamp bracket with impact and corrosion resistant including thermal management in multiple optics , efficacy 110/120 lpw , complete with ip 65/66 protection complete all as specified and directed. , supply and fixing in repair led flood light 80 watt 230 v ac outdoor type with thermal management in multiple optics and equipped with ip66 protection , with impact and corrosion resistant complete with driver and lamp , efficacy 110/120 lpw , including clamp , nut , bolts etc.complete all as specified and directed.make. crompton , cat no.lfl 80 cdl/60 hpm , supply and fixing in repair led flood light 150 watt 230 v ac outdoor type with thermal management in multiple optics and equipped with ip66 protection , with impact and corrosion resistant complete with driver and lamp , efficacy 110/120 lpw , including clamp , nut , bolts etc.complete all as specified and directed.make. crompton , cat no.lfln 150 cdl/60 m , s&f cable junction box 155x210x92 mm in size , made out of thermoplastic , having ip 66 protection for outdoor installation fixed with 4 way bakelite cable terminals including 03 nos polymide gland with check nut (m 32 02 no & m 25 01 no) fixed on poles with aluminium clamps of size 25x3mm , nuts , bolts , washers etc. including taking out of old unserviceable cable junction box complete all as specified and as directed. make. cat no. dk 1616g of hensel or equivalent model , supply and passing through steel tubler pole/service connection , 1100 volts grade multicore , fr , round insulated copper conductor and sheathed flexible cable , multistranded , three core of nominal cross sectonal area 1.5 sq mm , for connection of security light from junction box through pole /conduit with all terminals complete all as specified and as directed. , s and f single arm bracket made of40mm dia 1.0mtrs long for security light , with mounting ms clamp of flat iron size 25x5mm of suitable length 02 pairs including nut bolt etc of suitable size and painting to ms clamp with two coats of aluminium paints over a coat of red oxide netal primer all as specified and directed by engr in charge. , s & f in repair rigid non metallic pvc conduit of dia 20 mm exclusive of boxes (junction/terminal) but inclusive of all tees , bends , elbows , reducers , bell mouth tube ends and fixing accessories such as couplers , lock nuts , saddles , pipe hooks , clamps etc. all as specified and directed by engr in charge. , m and l for earthing complete with ms galvanised plate of size 60cmx60cmx6mm as earth electrode buried directly in ground earth pit not less tan 2.25mtrs deep below ground level with top edge of the plate not less tan 1.5mtrs below normal ground level connected to galvaniosed iron strip 32x6mm as earthing lead by means of bolts nut check nut and washers of galvanised iron welding or steel all as shown in electrical plate no 3 in ssr part i of 2009 connected to earthing test point all as specified complete with exevation and earth work pcc pit with 6mm thick ci ms cover having suitable handle 10mm ms rod with frame and locki
Tender For corrigendum : supply of amc for fast temperature change test chamber, model estc-710, make: tianyu equipment co. ltd. , china , amc for cyclic corrosion chamber, model ss13000g1, make: equilam brazil
Tender For conducting compressive strength test of concrete cores, chemical analysis and concrete tomography study with reinforcement corrosion evaluation of ramkrishna setu over river dwarakeswar situated at junction of sh- 2 and sh-7 pallishree, arambagh, ho