Tender For corrigendum : dismantling of existing panels , supply installation testing and commissioning of sub panels , re routing the existing power cable from msb panel to chiller 2 , re termination of existing lt & incomer outgoing cables earth connections etc
Tender For special repair of e i and fans in dr brairch at aiims new delhi sh supply, installation, testing and commissioning of 30kva three phase input and three phase output supply ups at 1st floor room no 156 and supply, installation, testing and commissioning of 40kva ups three phase input and three phase output supply at 4th floor room no 417 and 418 along with cubical panel incoming and outgoing cable sh a ups work sh b electrical work
Tender For pleadevelopment of 11 kv outgoing area including construction of cable trench for outgoing portion construction of approach road at the entrance portion of sub station construction of cover slabs construction of drain and other allied civil works wit
Tender For supply of setting up of high end audio conference board room b b -drawing of microphone cable , sitc of passive and basic accessories , sitc of electrical components and accessories for audio and video systems , sitc of pvc conduit pipes and casing capping along with the complete accessories , sitc of online ups 6kva , sitc of battery smf , sitc of hvac vrf system. 26. 0 hp top discharge outdoor , sitc of hvac vrf system. 2. 5 tr 4way cassette type , sitc of cordless remote controller , sitc of y joints and distribution joints. , sitc of copper refrigerant pipes , sitc of nitrile rubber insulation. , sitc of communication cable , sitc of refrigerant gas , sitc of acoustic ceiling , sitc of gypsum ceiling boards , sitc of wall acouistics lower part and front wall , sitc of wall acouistics upper part , supply and installation and construction of false partition wall 1 , supply and installation and construction of false partition wall 2 , sitc of structure for led display , supply and installation and construction of wooden flooring , supply and installation and construction of acoustic door , supply and installation and construction of u-shaped conference table , supply and installation of delegate conference room chairs , supply and installation of back conference chairs , supply and drawing of wires of following sizes of frls pvc insulated multi stranded copper wires in surface and recesses frls pvc conduict as reqd 2x1. 5 sq mm plus 1x1. 0 sq mm earth wire , supply and drawing of wires of following sizes of frls pvc insulated multi stranded copper wires in surface and recesses frls pvc conduict as reqd 2x2. 5 sq mm plus 1x1. 5 sq mm earth wire , supply and drawing of wires of following sizes of frls pvc insulated multi stranded copper wires in surface and recesses frls pvc conduict as reqd 2x4 sq mm plus 1x2. 5 sq mm earth wire , supply and fixing of following sizes of frls pvc conduit along with all accessories in surface and recess including cutting the wall and making same in case of recessed conduit 20mm dia , supply and fixing of following sizes of frls pvc conduit along with all accessories in surface and recess including cutting the wall and making same in case of recessed conduit 25mm dia , supply and fixing of following sizes of frls pvc conduit along with all accessories in surface and recess including cutting the wall and making same in case of recessed conduit 20mm dia flexible pipe , providing and fixing of 6m gi box complete in all respect. , sitc of surface or recessed db board ip 42 fabricated from 16 swg crca sheet, indoor type with cu busbar, 8 way tpn db with 63a 4p mcb incoming and 63a dp rccb 30ma, outgoing 18 sp mcb as rqd , sitc of surface or recessed db board ip 42 fabricated from 16 swg crca sheet, indoor type with cu busbar, 6 way tpn db with 63a 4p mcb incoming and 63a dp rccb 30ma, outgoing 12 sp mcb as rqd , sitc of following modular switch and socket with modlular switch plate including connections etc. as required 6 nos 6a switch with modular plate , sitc of following modular switch and socket with modlular switch plate including connections etc. as required 2 nos 6a socket outlets controlled by 2nos 6a switch with modular plate. , sitc of following modular switch and socket with modlular switch plate including connections etc. as required 2 nos 16a socket outlets contrlled by 2 nos 16a switch with modular plate. , sitc of light and light fixtures. cove light or cove light in channel as required by department , sitc of f light and light fixtures. ceiling or surface or wall light fixture 2x2 led panel of 36w as required by department , sitc of light and light fixtures. ceiling or surface or wall light fixture spot, downlight 10 watt as required by department , //bid details2 / 52comprehensive annual maintenance contract for 3 year amc and onsite maintenance service for 1 year
Tender For tender for supply of design and engineering of imcc panel 2 nos and vfds and plc network , design and engineering of apfc and hvac , design and engineering of apfc and field instruments , design and engineering of cables and termination and airconditioning for imcc building , design and engineering of earthing of imcc , field equipments and soil testing , design and engineering of civil buildings and structure foundations , design and engineering of imcc building with earthing system , design and engineering of structural works for cable laying for both incoming and outgoing cables , design and engineering of lighting system of imcc building , equipment locations at ccr ground floor and along the structural path for cable route , design of fire detection and alarm system for building and cable alley area along with integration and display at fire station/existing control centre , supply of imcc panels , vfd panels , supply of apfc panels , hvac system/ air conditioning systems for imcc building and other area air conditioners as mentioned in scope of work , supply of mldb , lighting distribution boards , lighting material including db , light fittings , and all related accessories or wiring material and other electrics etc , supply of field instruments and necessary piping materials as required , supply of plc and other related required accessories , supply of lt cables and other related accessories for electrical , termination material and other instrumentation cables etc and other related electrics as required , supply of cable trays for electrical and instrumentation , supply of all earthing material as per is 3043 for imcc and connection to earth pits for motors , panels etc , supply of fire detection and alarm system for building and cable alley area along with integration and display at fire station/existing control centre , erection , testing , commissioning , and handover of equipments of imcc panels and vfd panels , erection , testing , commissioning , and handover of equipments of apfc panels and hvac system , erection , testing , commissioning , and handover of equipments of lighting system as per above supply , erection , testing , commissioning of earthing system , erection , testing , commissioning of field instruments and necessary piping materials etc as required , erection , testing , commissioning and handover of plc , erection , laying , testing and commissioning of lt cables cable terminations wherever required along with necessary accessories is in the scope of the contractor for electrical and instrumentation , erection , testing and commissioning of cable trays for electrical and instrumentation , erection , testing and commissioning of fire detection and alarm system for building and cable alley area along with integration and display at fire station or existing control centre , substructure excavation , foundation works footings , columns up to plinth level , dpc damp proof course , and backfilling. , superstructure columns , beams , slabs , brickwork or masonry for all floors above plinth level , and formwork up to ground floor , finishes plastering , flooring tiles , marble , painting , wall cladding , and other interior or exterior finishes , plumbing works , fixing of doors up to ground floor. , superstructure columns , beams , slabs , brickwork or masonry for all floors above plinth level , and formwork for subsequent floors as per approved design , finishes plastering , flooring tiles , marble , painting , wall cladding , and other interior or exterior finishes , plumbing works , fixing of doors for subsequent floors as per approved design , supply and erection of structural works for cable laying for both incoming and outgoing cables