Tender For corrigendum : tender for purchase of pathology materials-reagents and consumables for nmmc hospitals (for year 2025-26-2026-27) - 75 test cartridge for blood gas analyser gem premier 3000, bulb for microscope 6 v / 20w, capillary for bt-ct ( 1 x 100 no), copper sulphate powder (500 gm), coverslips 22x22mm x10 gm, coverslips 22x30mm x10 gm, diamond marker ( glass cut pencil), distilled water biochemistry gr ( 1 x 5000 ml), e.s.r. pipette western green (glass), e.s.r. stand (12 tube metal body, press button type ), falcon tube 50 ml sterile, fields stain a ( 1 x 500 ml), fields stain b ( 1 x 500 ml), filter paper ordinary ( 1 x 100 sheet), handiplast (round) for blood donors, heam test kit ( 1 x 200 test), heavy liquid paraffin oil (1x 500 ml), high power lens (40x) for labomed microscope, low power lens (10x) for labomed microscope, immersion oil ( 1 x 100 ml), lancet, lens cleaning paper ( 1 x 100), methanol based slide fixative ( 1 x 500 ml), micro pipette fix volume 10ul, micro pipette fix volume 50ul, micro pipette fix volume 100ul, micropipette fixed volume 1000 l, micro pipette variable volume 100-500ul, micro pipette variable volume 10-100ul, micro pipette variable volume 5-50ul, micro pipette variable volume 100-1000ul, micropipette non digital variable volume 0-100 ul, microscopic glass slides (1 x 50 slides), multichannel pipette, n/10 hcl (500 ml), neubaur chamber (bright line), oil immersion lens with adapter for labo/labomed microscope, phenyl crystal 99.5% (500 gm), sodium hypochlorite (5% diluted) ( 5 lit jar), sterile swab sticks for culture sensitivity ( 1 x 100 swab sticks), sulphuric acid 98 % ( 500 ml), temperature recording circular chart papers (-)100 c to (+)100 c, temperature recording circular chart papers (-)50 c to (+)50 c, temperature recording circular chart 0 c to 40 c, temperature recording pen, test tube 3 x 11mm, test tube 4 x 11mm, thermal paper roll (57 mm x 30 m) for printer (1kit = 03 roll), thermal paper roll (56 mm x 30 m) for printer (1kit = 03 roll), 50 mmx25mm ch 1000 lablles x 1 roll (for fully atomated urine analyser, 55 mm x 300 mts wax (for fully automated urie analyser), thermometer (-)10 c to (+)100 c, thermometer (-)100 c to (+)100 c, tips for micropipette 200 l yellow tips ( 1 x 1000 tips), tips for micropipette 500 l blue tips ( 1 x 1000 tips), tips for micropipette 1000 l, tourniquet, whatman filter paper ( 1 x 100 paper), retic stain (10 ml), litmus paper ( 100 numbers), coplin jar 60 ml capacity plastic material, coplin jar 60 ml capacity glass material, bariun cloride 500 ml, selvinoffs reagent 500 ml, fructose reagent 500 ml, dpx mountant 500 ml, grams stain kit, naoh (0.1 n) 500 ml, spirit lamp, semen diluting fluid (100 ml), leugols iodine 100 ml, tissue roll, giemsa stain(1x500ml), slide preservation box for 100slides, slide staining cradle, slide drying rack, slide rack, deionised water (5lit), wooden spatula, blood collection needle holder, multi sample needle 22 g, non vaccum blood collection tubes pet material edta (k3), 3-5 ml, rubber stopper & plastic cap of lavender colour, non vaccum blood collection tubes pet material fluorude 3-5 ml, rubber stopper & plastic cap of gray colour, non vaccum blood collection tubes pet material plain with clot activator, 3-5 ml, rubber stopper & plastic cap of red colour, sputum container( 30 ml transparant, pp material, screw cap.), urine & stool container 50ml with lid (specimen container), vaccum blood collection tubes pet material gel with clot activator tube 3-5 ml rubber stopper & plastic cap of golden/yellow colour, vaccum blood collection tubes pet material edta (k3),3-5 ml rubber stopper & plastic cap of lavender colour, vaccum blood collection tubes pet material fluorude , 3-5 ml rubber stopper & plastic cap of gray colour, vaccum blood collection tubes pet material plain tube with clot activator 3ml rubber stopper & plastic cap of red colour, vaccum blood collection tubes pet material sod
Tender For supply of humidity and air temperaturecontrolunit : : - ac 2 ton inverter , ac 2 ton split , ac 1.5 tin split inverter , ac 2 ton inverter hot and cold , ac 1.5 ton window , desert cooler , cooler fiber indoor
Tender For corrigendum : purchase of various testing advanced apparatus (lab equipment) in quality control labs under zone bharatpur, jaipur-i and jaipur-ii, jodhpur-i and jodhpur-ii, kota and tonk. - ultra sonic pulse velocity testing instrument :-supplying ultra sonic pulse velocity testing instrument for non destructive testing (ndt) of hardened concrete to asses the quality of concrete in term of dense, homogeneity and uniformity. instrument shall also be capable of crack & void detection and elastic properties measurment of concrete. the apparatus for ultra sonic pulse velocity measurment shall consist electrical pulse generator, transducers in one pair, standard calibrator bar, amplifier, electronic timing device. performance requirement of apparatus shall be as under :-- transit time accuracy within - 1 % range- range of time - 20 s to 10 ms- referance specimen - two no. usually steel bars having pulse transit time 25 s to 100 ms with accuracy 0.2 s- transducer - one pair - piezo electric and magneto strictime type frequencies in between 10khz to 200 khz, contact type ultra sonic concrete tester range - upto 5 mtr. & 5 mtr. and aboveaccuracy - 100 nano second, power - 7.2 v (dc), rechargable bettary - oper. temperature - 0 to 500 c - resolution - 0.1 s- display - 128x64 graphic lcd - display response time - instantaneousstandard accessories :-1- 1 set of 7.2 v nicd cell2- probe cable 2 no. (4m each)3- transduces - 2 no. (50 mm dia, 60 khz)4- calibration block alongwith verification block with nabl traceability certificate5- cover /bag instrument shall meet requirements of is: 516(part-5/sec.-i) 2018, en 12504-1 & astm c 597. standards.the complete item shall be supplied as per direction of engineer in charge . rates are inlusive of all taxes ., rotational viscometer : supplying & installation of rotational viscometer of spring torque model for higher viscosities that specially designed for conducting high-temperature testing of ashphalt binders in compliance with astmd 4402/d4402m-23 and is: 73-2013,is :15462-2019 & is:17079-2019 .standards . it should be capable to determine viscosities of liquids. like oil, ashphalt & solvent etc.key feature of apparatus shall be as under :-precise temperatures controlunit to ensure precise temp control and maintaining content & accurate testing temperatures.user friendly inter face to easy to use and display of accurate result.level indicators surface level indictors should be our both the temp controlunit and the main unit to ensure equipment remain level., versatile spindle options capable of with standing the demanding condition of ashphalt testing., builtin micro printer for convenient result printing., automatic range calculation capable of automatic full scale range (fsr) calculation for 100 % viscosity with specific spindle and speed combination., window based software shall include window based software for creating viscometer vs temperatures course with test data continently stored ms excel., high-visibility lcb the lcb display features a white backlight for enhanced visibility and clarity.technical specifications of apparatus shall be as under :-rotation speed 0.1- 250 rpm, viscosity measurement range 100 cp to 64m cp, torque range high up to 57496 dyne.cm ( 5.749 mn.m) ,, spindles set of large spindles as required, torque range 10%- 100% full -scale torque, measurement error: 1% (f s), temperaturecontrolling range: up to 200 c, temperaturecontrolling accuracy: 0.1 c, cubage of sample cylinder: 20ml, serial interface: rs232, working environment: ambient temperature: 15 c to 35 c, 85%, operating voltage: ac (220v 10%)v, 50hz, single phase, total power consumption: 200w, components included of apparatus shall be as under :- -head of viscometer -auxiliary controlling case (containing a temperaturecontroller and a micro-printer), - thermo-electric heater, -spindles made of aisi 316l as per requirment with adaptor, -pen drive for pc software setupstand, ext