Web Analytics Made Easy - StatCounter

Temperature Humidity Tester Tenders

Get complete information related to latest Temperature Humidity Tester Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Temperature Humidity Tester Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Temperature Humidity Tester Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

Central Government/Public Sector

CTN :43029124 Due date: 17 Dec, 202517 Dec, 2025 NA
Tender For supply of fqa lab mechanical for lara and talcher project d d -- magnetic particle inspection yoke type-02 nos, pie gauge for mpi-02 nos, radiography film densitometer-02 nos, uv lamp for fluorescent mpi and dpt-02 nos along with all accessories , group-5 - stay at site including lodging, boarding, local conveyence etc for supervision of erection and commissioning etc at site-02 days in talcher and 02 days in lara , group-5 - site visit - - should include travel expenses to-fro site, visa- insurance-if applicable, intermediary stay- for sup of e and c etc at site-01 visit in talcher and 01 visit in lara , group-6 - radiation survey meter-02 nos, personal digital dosimeter-04 nos, ultrasonic testing machine-conventional with probes and calibration blocks-02 nos with all accessories , group-6- stay at site including lodging, boarding, local conveyence etc for supervision of erection and commissioning etc at site-02 days in talcher and 02 days in lara , group-6 - site visit - should include travel expenses to-fro site, visa- insurance-if applicable, intermediary stay- for sup of e and c etc at site02 visit in talcher and 02 visit in lara , group-7- digital radiography-02 nos along with all accessories , group-7stay at site including lodging, boarding, local conveyence etc for supervision of erection and commissioning etc at site-04 days in talcher and 04 days in lara , group-7 - site visit - - should include travel expenses to-fro site, visainsurance-if applicable, intermediary stay- for sup of e and c etc at site-02 visit in talcher and 02 visit in lara , group8- optical microscope for replica interpretation,optical microscope and image analysis system, stereo microscope with camera attachment-02 nos , group-8- stay at site including lodging, boarding, local conveyence etc for supervision of erection and commissioning etc at site-01 days in talcher and 01 days in lara , group-8- site visit should include travel expenses to-fro site, visa- insurance-if applicable, intermediary stay- for sup of e and c etc at site02 visit in talcher and 02 visit in lara , group-9- computed radiography-cr-scanner-02 nos-alongwith all accessories please refer price schedule , group-9- stay at site including lodging, boarding, local conveyence etc for supervision of erection and commissioning etc at site-04 days in talcher and 04 days in lara , group-9- site visit - - should include travel expenses to-fro site, visa- insurance-if applicable, intermediary stay- for sup of e and c etc at site-02 visit in talcher and 02 visit in lara , group-10- hardness tester rebound type-02 nos and hardness tester_uci method-02 nos-along with all accessories , group-10- stay at site including lodging, boarding, local conveyence etc for supervision of erection and commissioning etc at site-02 days in talcher and 02 days in lara , group-10- site visit - should include travel expenses to-fro site, visa- insurance-if applicable, intermediary stay- for sup of e and c etc at site01 visit in talcher and 01 visit in lara , group-11radiography film viewer-04 nos, radiography film samplesasme-02 nos , magnetic particles inspection-coil type with cable-02 nos, gaussmeter for mpi-02 nos, ni-cr panel for dpt-02 nos , group-11- stay at site including lodging, boarding, local conveyence etc for supervision of erection and commissioning etc at site-02 days in talcher and 02 days in lara , group-11- site visit - - should include travel expenses to-fro site, visa- insurance-if applicable, intermediary stay- for sup of e and c etc at site-01 visit in talcher and 01 visit in lara , group-12-pls refer item description and price schedule for details_holiday detector, stethoscope, vibration meter, comparator, roughness meter, noise meter, torque wrench etc , group-12- stay at //bid details2 / 46site including lodging, boarding, local conveyence etc for supervision of erection and commissioning etc at site-10 days in talcher and 10 days in lara , group-12- site visit - should include travel

Central Government/Public Sector

CTN :41587302 Due date: 06 Jan, 202606 Jan, 2026 6.64 Crore
Tender For corrigendum : supply of sitc of 24 core single mode armoured optical fiber cable , sitc of 12 core single mode armoured optical fiber cable , sitcof 50 pair jelly filled outdoor telephone cable , sitc of 20 pair jelly filled outdoor telephone cable , sitc of 15u wall mount networking rack with all accessories , sitc of 24 port rack mount liu fully loaded with sc to sc couplers , sitc of 12 port rack mount liu fully loaded with sc to sc couplers , sitc of 100 pair plus 100 pair main distribution box , sitc of 50 pair plus 50 pair main distribution box , sitc of hdpe pipe size 40mm , sitc of gi pipe size 65mm , sitc of sc to lc single mode 3mtr fiber patch cord , sitc of sc to lc single mode 1mtr fiber patch cord , sitc of cat6 utp cable 305mtr roll , sitc of cat6 patch cord 3mtr , sitc of cat6 patch cord 1mtr , sitc of mdf with internal pipe for entry of cables cable glands , sitc rcc chambers with precast rcc cover with lifting hooks , sitc of joint enclosure for 24 core ofc jointing work , sitc of joint enclosure for 12 core ofc jointing work , laying clamping of 24 core and 12 core ofc in duct , laying clamping of 50 pair and 20 pair telephone cable , sitc of cable route markers as per specifications , digging of soft soil and backfilling as per original site condition , digging of hard concrete surface road crossing and refilling , machine horizontal directional drilling hdd for crossing hard surface , otdr report and power meter testing , supply design and provide auto cad as built drawing
 Loading, Please wait...

Connect us via What's Up