Web Analytics Made Easy - StatCounter

Temperature Measurement Tenders

Get complete information related to latest Temperature Measurement Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Temperature Measurement Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Temperature Measurement Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

CTN :42231136 Due date: 24 Oct, 202524 Oct, 2025 46.83 Lacs
Tender For corrigendum : construction of a measuring devices on the entire canal system for irrigation using volumetric metering method for the water user organization under ambhora lift irrigation scheme stage-2.

CTN :41939896 Due date: 24 Oct, 202524 Oct, 2025 NA
Tender For corrigendum : tender for supply of supply of hot axle box detection system : : - hot box detection system , design and submission of design documents , fai and fat report type tests , special tools and measuring devices , training , training manual

corporations/Associations/Others

CTN :41764135 Due date: 24 Oct, 202524 Oct, 2025 11.92 Lacs
Tender For corrigendum : supply of miscellaneous control and instrumentation items for btps, obra. - lubricator air filter with pressure gauge max. inlet pr. 15kg/cm2 outlet pr. range: 0-10kg/cm2 connection: 3/4" npt, manual drain 40micron sintered bronze/ metal bowl filter element, lubricator air filter with pressure gauge max. inlet pr. 15kg/cm2 outlet pr. range: 0-10kg/cm2 connection: 3/4" npt, manual drain 40micron sintered bronze filter element, stub for steam line and w.o. outlet bfp (as per sample), thermowell for steam / water line and w.o. (as per sample), thermocouple k-type duplex with head l-400mm od-19mm, k- type thermocouple od-6mm l-320mm bsp (m), k- type without head connation thermocouple for boiler/ turbine metal temperature measurement l-15mtr, od-6mm, rtd (prt-100*ohm*) thermocouple type along with thermowell head connection 320mm, od-6mm duplex bsp, rtd (prt-100*ohm*) capsule type thermocouple along with thermowell head connection l-20mm, od-4mm, (20x10) & od-3mm (5 nos) duplex type m&f adjust, k- type thermocouple od-6mm l-400mm bsp (m), pa fan temp. switches 0-120 deg. c1. dial size: 150 mm normal dia, white back ground, black marking2. range: 0 120 c3. case: weather proof to ip: 65 as per is:13947, die cast aluminium, bezel ring4. stem: 10 mm dia in ss 316, total stem length-200 mm5. connection: 3/4" npt(m) gland table in ss3046. capillary: ss 304 covered, 10 meter long solid drawn7. accuracy: 1% of fsd for indication & 2% of fsd for switching8. over range: 120 % of fsd9. window: acrylic10. contacts: 2spst contact, both normal op to close on rise of temperature rated 30 va, 240 v ac., temperature switch: fd fan stem length 175mm, 0 120 deg. c with sleeve zero adjustment at outside the casing along with fitting.tech. specification: -1. dial size 100 mm nominal dia, white back ground, black marking.2. range 0 120 deg.c.3. case weather proof p: 65 as per is: 2147, die cast aluminium with screwed aluminium, bezel ring.4. stem 10 mm dia in ss 316, total stem length-175 mm.5. connection 1/2" npt (m) gland adjustable in ss304.6. capillary ss 304 covered + pvc coating, 03 meter long.7. accuracy of fsd for indication 2% of fsd for switching.8. over range 120 % of fsd.9. window acrylic.10.contacts 1spst contact, both normal open to close on rise of temperature rated 30 va, 240 v ac., temperature switch stem size 300mm for id fan temperature switch: stem length 300 mm, 0 120 deg. c with sleeve zero adjustment at outside the casing along with fitting.other tech. specification: -1. dial size 100 mm normal dia, white back ground, black mar 2. range 0 120 deg. c.3. case weather proof to ip: 65 as per is: 2147, die cast aluminium with screwed, bezel ring.4. stem 10 mm dia in ss 316, total stem length-300 mm.5. connection 1/2" npt (m) gland adjustable in ss304.6. capillary ss 304 covered with coating, 03 meter long.7. accuracy 1% of fsd for indication 2% of fsd for switching.8. over range 120 % of fsd.9. window acrylic.10. contacts 1 spst contact, both normal open to close on rise of temperature rated 30 va, 240 v ac, temperature switch stem size 150mm temperature switch: stem length 150 mm, 0 200 deg. c with sleeve zero adjustment at outside the casing along with fitting.other tech. specification:1. dial size 150 mm normal dia, white back ground, black marking2. rang 200 deg. c3. case weatherproof to ip: 65 as per is:2147, die cast aluminium with screwed, bezel ring4. stem 10 mm dia in ss 316, total stem length-150 mm5. connection 1/2" npt(m) gland adjustable in ss3046. capillary ss 304 covered with pvc coating, 03 met ng7. accuracy 1% of fsd for indication 2% of fsd for switching8. over range 120 % of fsd9. window acrylic10. contacts 1spst contact, both normal open to close on rise of temperature rated 30 va, 240 v ac, digital ind 4 digit dual channel 138x32mm, digital ind 4 digit single channel 138x32mm, 3 nos.)

Central Government And Public Sector

CTN :42323250 Due date: 14 Nov, 202514 Nov, 2025 NA
Tender For supply, installation and commissioning of automatic computerized temperature measurement (habd) as per rdso specification no. rdso-spn-re-hahw-2017(rev-2) dated 23/12/2022 as per schedule of requirements. (rdso specification and distribution list attached)

Central Government/Public Sector

CTN :42218835 Due date: 31 Oct, 202531 Oct, 2025 NA
Tender For calibration of measuring instruments, gauges and testing devices.

State Government

CTN :41670814 Due date: 30 Oct, 202530 Oct, 2025 10.38 Lacs
Tender For corrigendum : charges for carry out oxygen mapping (flue gas analysis, draft measurement and temperature measurement) of unit 3,4,5,6 as and when require at ukai tps gsecl.(wt-5001 eeec)

CTN :42035760 Due date: 04 Nov, 202504 Nov, 2025 NA
Tender For corrigendum : procurement of various types of rtds (resistance temperature detector) used for temperature measurement for stage 2and 3 of ggsstp, rupnagar.

State Government

CTN :41676459 Due date: 17 Oct, 202517 Oct, 2025 NA
Tender For corrigendum : empanelment of agencies for supply of different laboratory instruments for various water testing laboratories under jal jeevan mission, assam - ion meter with electrode and accessories for fluoride & nitratemeter: ph/ion/ mv-redox-orp/ temperature benchtop meter with electrode for testing both fluoride & nitrate separately in water samples. technical specification: ph range: -2.000 to 20.000 resolution 0.1, 0.01, 0.001 accuracy 0.002 ph + 1 lsd calibration points up to 5 buffer sets: usa/ nist/ din/ custom orp range 2000.0 mv rel. mv range 2000.0 mv accuracy 0.2 mv resolution 0.1 mv ion concentration 0.001 to 19999 ppm resolution up to 3 digits relative accuracy 0.5 % full scale (monovalent) and 1 % full scale (divalent) calibration points up to 8 temperature range 0 to 100 c, 32 to 212 f resolution 0.1 accuracy 0.3 c/ 0.5 f compensation: auromatic temperature correction other requirement: auto buffer recognition, memory 500 with time and date stamp rs 232 alarm for calibration due & out of range alurm auto logging function., fluoride electrode of ion metersame make that of the ion meter, nitrate electrode of ion metersame make that of the ion meter, manifold filtration assembly (to be used for micobiological test)* sturdy and easy to clean ss filtration assembly with funnel, manifold unit, air vent filter and vaccum pump ready to be used for mictobiological testing * specification: # funnel with inbuilt clamp: made of ss 316, capacity: 300 ml, ss filter support base, ss support screan: 47 mm, made of ss 316l; filtration area 9.6 cm2; silicon stopper: size 8, with silicon lid and silicon o ring. # filtration manifold: 3 place manifold, made of ss 316, valves made of ptee, connection 12 mm; suitable for both pp and ss funnel with rubber stopper fittings. # vacuum pump: oil free, piston powered, suitable to be used with 3 possition manifold; max flow rate: 34 l/ min; vaccum stage: double. max vaccum: 100 mbar. the vaccum pump should also have a vacuum suction bottle to protect the pumps componennt by preventing liquid or solid material from entering the pump during filtration process., voltage stabilizer (3 phase)# capacity- 3 kva # input voltage range: 295 v - 465 v normal range # output voltage range 380 v / 400 v / 415 v # output regulation: 1 %; # output settability: 380 v - 420 v; # frequency: 47 hz - 53 hz; correction rate: 70 v/ sec; # aircooled servo stabilizer, three phase., heating mantle (single station) should have safety cut off with precise heating for boiling, evaporation, distillation or extraction process technial specification: flask capacity 250 ml, working temp range: ambiant + 5 to 350 degree celcius. accuracy: 1.0 degree celcius, display: led display with temperature, time; construction material: ms; power consumption : 150 w, semi automatic digestor for cod analysis with all assssories material of construction epoxy painted with chemical resistant coating; temperature range ambient to 450 deg c # stability of temperature 0.5 deg c # temperature calibration - automatic; selectable ramp: upto 4 per program; digestion time range: 1 to 999 minutes; time selection: 1 minutes steps; countdown: digital readout; heating places - 6 possition; size of tubes: 250 ml test tubes (42 mm); power 1000 w; number of programmable methods 20 numbers. # the thermal digestion unit should have high thermal homogeneity # the setup should have small footprint., digital thermometer with probe# mini lcd thermometer # type: digital, # sensor cable length: 1 meter water proof probe # batteries: 2 x batteries should be included, # temperature range: - 50 - 110 oc, # temperature measurement accuracy: 1 0c, micropippete stand#self-standing holder accommodates most major brands of pipettes. #material: pmma, # capacity: 5 pipptes/stand, conical flask draining rack#material: acrylonitrile-butadiene-styrene/polycarbonate, # no. of pegs: 20

CTN :42171931 Due date: 27 Oct, 202527 Oct, 2025 NA
Tender For supply of mini infrared thermometer as per attached specification for temperature measurement of emu traction motor and axle box

Central Government/Public Sector

CTN :42139951 Due date: 27 Oct, 202527 Oct, 2025 NA
Tender For calibration of different measuring & monitoring devices (mmds) and test benches at els/aq for 02 years.
 Loading, Please wait...

Connect us via What's Up