Get complete information related to latest Temperature Stub Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Temperature Stub Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Temperature Stub Tenders.
Tender For supply of details description of specification for 100 watt led flood light - led rating in warm)/system wattage/rated power, led luminaire conformity to 15:10322/part 5/section 5/2012 latest and 15: 16107, (part 2/sec 1):2012, photo biological safety of leds used shall be as per 15:16108/2012 (exempt grou, types of led luminave as per the 15: 161070part-2/sec-11/2012, types of led modules as per the 25: 16103(part 2)/2012, led rating/system wattage/rated power, luminaire system efficacy bumen/watt), ingress protection (ip rating) as per 1 10322 (part 1): 1982 latest, mounting brackets fincluded, warranty for free replacement (in year), input operating voltage range and frequency, automatic higher cut off voltage above 300 volt, rated voltage, ac power factor at hill load, driver efficiency lin sage), total harmonics distortion (in lage), the total circut power shall not be more than 110 percent of the valve declared, by the manufacturer, led chip efficacy, colour temperature (+500), working life for led (minimum 50,000 buming hours as per lm-80 report), coltur rendering index(cri), optic lenise materal (uv stabilued) (write na or without optic lense supply), heat sink should be die-cast aluminum along with sufficient heat sink fins to desipate heat effectively, capacitor shall be ratail for a temperature of 105 deg. ceblus or better, junction temperature, operating temperature range, operating humidity range, short circuit protection, overload protection, over voltage geutection, reverse polarity, high voltage test (1.5 kv for ane minute between napply terminats and body of the, unit), insulation resistance between earth and current carrying part, the luminaire shad be protected against surges and transients (internal), the luminaire shall be protected against surges and transients of >/1kv, (external, the luminaires casing/housing (single piece housing) shall be pressure de catted, aluminum alloy with higher thermal.conductivity, the lummaire body must be corrosion resistant epoxy powder couted, all fasteners must be of stainless steel, the entire housing (both led section and driver section) shall be dust and water proof having ip 66 protection as per 15:10322 (part 11:1987 latest, luminaries light transparency should be of toughened glass, toughened transparent glass cover thickness, toughened glass shall not get discolored shall not suffer degration due to heat and agning within warranty period, number of electronic control gest (power sanoles), driver components shall be industrial grade or above, pci shall be fre grade minimum 0.8 to 1.0 mm thick or mom, the luminaires works on single phase three wires system (phase, neutral and, earth, suitable connector shall be provided for led connection between driver output, and led, length of st marked three cors wire (shall be provided along with supply of, materiall, ught source, manufactures name and and brand on the aluminium die cast body, manufacturer's name, model number, serial number, date of manufactiare (month-year), and int number as identification mark inside each unit and the outside of each packaging box, the operation characteristics voltage and power be marked inside of each led, system must have emi/emc compliance as applicable (test reports shall be furnish on demand by buyer/consignee)
Tender For supply of pvdg ei and fans mv panel at wtr mw bldg ahmedabad c c - point wiring group c , wiring with 2c 4sq mm cu wire in pvc conduit with earthing , wiring with 4c 4sq mm cu wire in pvc conduit with earthing , wiring for sub main 2c 1.5 sq mm cu wire with earthing , wiring for sub main 2c 4 sq mm cu wire with earthing , wiring for sub main 4c 4 sq mm cu wire with earthing , s drawing 1c 1.5 sq mm cu wire in extg conduit , s drawing 2c 1.5 sq mm cu wire in extg conduit , s drawing 3c 1.5 sq mm cu wire in extg conduit , s drawing 4c 1.5 sq mm cu wire in extg conduit , s drawing 6c 1.5 sq mm cu wire in extg conduit , s fixing 20 mm medium pvc conduit , s fixing 25 mm medium pvc conduit , s fixing modular switch 5 or 6 amp , s fixing modular switch 5 or 6 amp 2way , s fixing modular switch 15 or 16 amp , s fixing modular 5 or 6 amp socket outlet , s fixing modular 15 or 16 amp socket outlet , s fixing bell push modular , s fixing modular blanking plate , s fixing metal box with lamnated sheet cover 1 or 2 module , s fixing metal box with lamnated sheet cover 3 module , s fixing metal box with lamnated sheet cover 4 module , s fixing metal box with lamnated sheet cover 6 module , s fixing metal box with lamnated sheet cover 8 module , s fixing metal box with lamnated sheet cover 12 module , s fixing metal box 100 x 100 x 60 mm , s fixing metal box 150 x 75 x 60 mm , s fixing metal box 180 x 100 x 60 mm , s fixing box with 3 no 5 or 6 a modular switch and sockets , s fixing box with 1 no 15 or 16 a modular switch and sockets , s fixing call bell buzzer 230 v ac , itc of prewired light fitting incl wiring , itc of ceiling fan incl wiring , s fixing 4 way double door mcb db 415v , s fixing 2 and 4 or 6 way double door mcb db 240v , s fixing single pole 5 to 32 amp mcb , s fixing single pole and neutral 5 to 32 amp mcb , s fixing 40 amp dp mcb , s fixing 63 amp triple pole and neutral mcb , s fixing 25 to 32 amp dp mcb with db , s fixing ms perforated poweder coated painted cable tray 150mm x 50 mm x 1.6mm , s fixing ms perforated poweder coated painted cable tray 300mm x 50 mm x 1.6mm , s fixing led 2x2 feet 18w , s fixing led 2x2 feet 36w , sitc bldc celing fan 1200 mm , sitc bldc celing fan 1400 mm , s fixing 2 step electronic fan regulator , s fixing metallic wall mounted air circulator fan , sitc furface mounted led battern light aluminium body 36w , laying on wall upto3.5c 35 sq mm cable , s and lay alcond cable 2c 6 sqmm xlpe , s and lay alcond cable 4c 6 sqmm xlpe , s and lay alcond cable 4c 10 sqmm xlpe , s fixing brass battern holder , s f computer spike guard 4 no outlet , s f 20 mm size pvc casing capping , s f pvc exhaust fan 200 mm to 300 mm 1 phase , s f metal body exhaust fan 200 mm to 300 mm 1 phase , sitc led streetlight fitting 30w al body , s f pvc box with 20a spn and timer , s f ms adopter box , sf ms angle iron frame structure incl cutting welding etc , sitc indoor power paned with 200a tpn sfu and 200a fp onload changeover as incomer etc , itc of 1.5 or 2 tr split ac units , sf add copper pipe with cable for sac , s f powder coated iron stannd of ac outdoor unit , sf 3 c 2.5 sq mm cu cond flexible cable , sf25 mm pvc isi drain pipe , earthing with 600x600x6mm gi earth plate , pf 25x5 mm gi earth strip in 40mm gi pipe , pf 25x5 mm gi earth strip on surface , pf 6 swg gi wire , sitc heat detector for fda system , sitc smoke detector for fda system , sitc manual call box for fda system , sitc response indicatorfor fda system , sitc alarm sounder for fda system , sitc of sector paned of fda system 4 zone , sitc of sector paned of fda system 6 zone , s laying 2c 1.5sq mm fire alarm armoured cu conductor , //bid details 2 / 70 endtermi for 2 c 1.5 sq mm , sf gi box of 100x100x6 mm for fda panel
Tender For supply, erection, modifying & commissioning of lighting system at sikka tps. - copper cable 4 corex2.5 mm2,1100 volts annealed tinned copper cond.as per is 1554(part-i)/1988., copper cable 2 corex2.5 sqmm,1100 volts annealed tinned copper cond.as per is 1554(part-i)/1988., 20 amp. 240v spn industrial type socket outlet with 2 pole and earth metal enclosed plug top along with 20 amp. c series sp mcb in sheet steel enclosure on surface with chained metal cover for the socket out let., junction box, made from 18 gauge crca sheet powder coated 150 mm x 150 mm with 4 way connector and ip 54 protection, gi flexible pipe size: 20mm dia. heavy duty, steel conduit pipe size: 20mm dia. thickness-1.6 mm, gi ladder tray size 800 mm for cable, 4 way lighting distribution panel, mcb 16 amp,, mcb 3 phase,4 pole, 63 amp 440 v ac 50 hz 10 ka, 80-watt led lamps industrial well glassed luminari fixture, alluminium cable 3.1/2 corex35 sqmm lt, work of wiring, testing & commissioning of led flood/ well glass light fitting., laying charges for pvc armoured l.t. cable size (1-core to 4-core) 16mm2 to 95mm2 in cable tray/trench as per instruction of eic., work of connection, wiring & drawing of 4cx2.5/ 2cx1.5 mm2 size isi mark 1100 grade frls pvc insulated multi strand flexible copper including earth wire from lp to jb to luminaries & receptacles in existing steel conduits., work of fixing 20 amp. 240v spn industrial type socket outlet with 2 pole and earth metal enclosed plug top along with 20 amp. c series sp mcb in sheet steel enclosure on surface with chained metal cover for the socket out let., labor charges for removing existing lighting fixtures/ lamps with junction box/ fittings etc and to credit at main store., labor charges for removing existing wiring/ cables /conduits etc and to credit at main store., work of fixing, connection, testing and commissioning of lighting panel with 24/18 outgoing ckt. double door, insulated bus bar, insulated neutral bars, earth bar, cable ties, circuit identification labels., work of fixing, connection, testing and commissioning of mcbs (3 pole+ neutral) current rating 63amp in the above lp., work of fixing, connection, testing and commissioning of single pole mcb 16 amp in the above lp., work of fixing steel conduit 25 mm size, dia. 1.6 mm., work of installation of junction box, made from 18 gauge crca sheet powder coated 250 mm x 200 mm x 105 mm including all hardware like angle, support, cable gland and connector., work of installation of gi flexible pipe 25 mm dia. heavy duty to protect wiring from dust & moisture at lp & luminary termination., work of installation of hot dip galvanized cable tray size 200x50x50, 16swg isi standard make.