Tender For corrigendum : tender for supply of resistance temperaturetransmitter and indicator - resistance temperaturetransmitter ( resistance to current converter) , make -elektra precision .input- rtd pt-200. temperature range 0-100 degree centigrade , output- 04 to 20 ma dc (two no of output) zero & span adjustable. power supply- 118 vac with connector. other detail as annexure-1.(bidder should comply one to one in specification as attached) , spare elektra ( earlier lektrolab ) make resistance temperaturetransmitter. input rtd pt.200. temp range- 230 - 320 degree centigrade. o/p- 04 to 20 ma dc. single output. other common details as per attached annexure-1. , spare elektra ( earlier lektrolab ) make resistance temperaturetransmitter. input rtd-pt.200. temp range- 0-320 degree centigrade. output- 04 to 20 ma dc with double isolated outputs. other common details as per attached annexure-1. , resistance temperaturetransmitter ( resistance to current converter) , make-elektra precision .input- rtd pt-100. temperature range 0-100 degree centigrade , output- 04 to 20 ma dc (two no of output) zero & span adjustable. power supply- 118 vac with connector. other detail as annexure-2.(bidder should comply one to one in specification as attached) , indicating alarm meter , make - m/s elektra precision systems , tag-flow indicating alarm meter , range-0-400 ft/sec , alarm -high , alarm relay-one for high alarm , input -4-20ma , mounting arrangement-4b , normal operating 118 v ac , 50 hz +/-10 percent , indicating alarm meter , make - m/s elektra precision systems , tag-temperature indicating alarm meter , range-0-100 degree c , alarm -high , alarm relay-one for high alarm , input -4-20ma , mounting arrangement-1a , normal operating 118 v ac , 50 hz +/-10 percent , indicating alarm meter , make - m/s elektra precision systems , tag- differential pressure indicating alarm , range- -15 to +25 gm/cm2 , alarm -high , alarm relay-one for high alarm , input -4-20ma , mounting arrangement-1a , normal operating 118 v ac , 50 hz +/-10 percent , indicating alarm meter , make - m/s elektra precision systems , tag- flow indicating alarm , range- 0-700 (squre root scale flow) lpm , alarm -low , alarm relay-one for low alarm , input -10-50ma , mounting arrangement-4b , normal operating 118 v ac , 50 hz +/-10 percent , indicating alarm meter , make - m/s elektra precision systems , tag- temperature indicating alarm , range- 0 to 70 degree c , alarm -low/high , alarm relay-one for high alarm and one for low alarm , input -4-20ma , mounting arrangement-4b , normal operating 118 v ac , 50 hz +/-10 percent , indicating alarm meter , make - m/s elektra precision systems , tag- flow indicating meter , range- 0-6 (squre root scale) klpm , alarm -no alarm , alarm relay-no alarm , input -10-50 ma , mounting arrangement-4b , normal operating 118 v ac , 50 hz +/-10 percent , indicating alarm meter , make - m/s elektra precision systems , tag- level indicating meter , range- 0-10 meter , alarm -no alarm , alarm relay-no alarm , input -4-20 ma , mounting arrangement-4b , normal operating 118 v ac , 50 hz +/-10 percent , indicating alarm meter , make - m/s elektra precision systems , tag- flow indicating meter , range- 0-10.7 meter / sec & 0-30 feet /sec , alarm -high , alarm relay-one for high alarm , input -4-20 ma , mounting arrangement-4b , normal operating 118 v ac , 50 hz +/-10 percent , indicating alarm meter , make - m/s elektra precision systems , tag- flow indicating meter , range- 0-10.7 meter / sec & 0-30 feet /sec , alarm -high , alarm relay-one for high alarm , input -0-4 ma , mounting arrangement-4b , normal operating 118 v ac , 50 hz +/-10 percent , indicating alarm meter , make - m/s elektra precision systems , tag- pressure indicating alarm meter , range- 0-0.7 kg/cm2 , alarm -high/low , alarm relay-one for high alarm & one for low alarm , input -4-20 ma , mounting arrangement-4b , normal operating 118 v ac , 50 hz +/-10 percent , i
Tender For corrigendum : supply of supply differential pressure transmitter at mdpl jaipur , supply of temperaturetransmitter at mdpl jaipur , supply of pressure transmitter at mdpl jaipur , supply of pressure transmitter at mdpl awa
Tender For supply of temperaturetransmitters for fd fan bearings,temperaturetransmitters for id fan bearings,temperaturetransmitters for pa fan bearings,temerature transmitter for sa fan bearing
Tender For supply of rtd mux, 848tfi1s001t1b6ja5c1q4 -high-density temperaturetransmitter(mux); communications protocol: foundationfieldbus digital signal; no of channels:08 product certification: atex intrinsic safety;input type: resistance temperature detectors (rtd) and thermocouples inbuilt transientprotection; model:848tfi1s001t1b6ja5c1q4; make: emerson process management
Tender For supply of w96716155937 drg: 31611770113 rev: 00 condenser air evacuation package (vacuum pump) spec: he57016 re , w96716155317 drg: - rev: 00 complete vacuum pump (bare shaft vacuum pump) spec: he57016 rev: 04 , w96716155325 main motor for vacuum pump spec: he57016 rev: 04 , w96716155465 heat exchanger for vacuum pump package. spec: he57016 rev: 04 , w97716155580 impeller & shaft assembly (complete) , suitable for 30 scfm vacuum pump. spec: he57016 r , w97716155253 coupling complete (for vacuum pump of 30 scfm) spec: he57016 rev: 04 size: to suit the , w97716155059 bearing for vacuum pump (30 scfm) (1set= 2 nos) spec: he57016 rev: 04 size: to suit origi , w96716155589 complete set of gaskets, o-rings for heat exchanger spec: he57016 rev: 04 , w97716152050 complete set of mechanical sealing assembly (de&nde) / gland packing assembly (as applic , w97716155431 seal water recirculaton pump asembly(along with motor etc. ) - for 30 scfm vacuum pump s , w97716155822 pressure transmitter for vacuum pump system: 0-1 bar abs spec: he57016 rev: 04 , w96716155813 level transmitter for vacuum pump spec: he57016 rev: 04 , w96716155210 drg: 31611770047 rev: 00 differential pressure switch for vacuum pump. spec: he57016 rev , w96716155490 flow indicator cum switch for vacuum pump spec: he57016 rev: 04 , w97716155547 level gauge for vacuum pump separator tank spec: he57016 rev: 04 size: to suit original , w97716155733 drg: to suit original supply rev: 00 pressure gauge (0 to -1 bar) , w97716155741 drg: to suit original supply rev: 00 pressure gauge (service water) , w97716155466 temperature gauge 0-100 deg c, for vacuum pump heat exchanger size: 0 to 100 deg c , w96716155457 differential pressure gauge for vacuum pump package duplex filter spec: he57016 rev: 04 , w97716155849 drg: to suit original supply rev: 00 air flow meter (rotameter) for vacuum pump system s , w96716155244 drg: 31611770051 rev: 00 temperaturetransmitter for vacuum pump spec: he57016 rev: 04 , w97716152033 temperature element for vacuum pump spec: he57016 rev: 04 , w97716152041 thermowell for temperature element spec: he57016 rev: 04 , supervision of commissioning lump sum per man day charges at site, including every expense at our si , supervision of commissioning lump sum per visit charges (to &fro) including travelling time & all ex
Tender For supply of temperaturetransmitters for fd fan bearings,temperaturetransmitters for id fan bearings,temperaturetransmitters for pa fan bearings,temerature transmitter for sa fan bearing
Tender For turnkey instrumentation (mkk/b903-000-yk-mr-2090/16) - supply of following items as per complete scope of mrgroup-a (as per mr top sheet)- instrumentation- b903, beacons, breather valves, differential pressure gauges, differential pressure flow transmitters, orifice plates & flanges, mass flow meter, gas detectors (hc/lel, h2s), guided wave radar lt, handheld configurator, hooter with push buttons, loop powered indicators, pressure gauges, pressure relief valves, pressure transmitters, radar level transmitters, temperature elements (rtd & thermowells), temperature gauge and thermowells, temperaturetransmitters, per diem rate for supervision of erection, testing and commissioning of mass flowmeters, gas detectors , radar level instruments - non-contact top mounted, guided wave radar - top mounted as per enclosed instructions to vendor.