Get complete information related to latest Terminal Board Scrap Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Terminal Board Scrap Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Terminal Board Scrap Tenders.
Tender For procurement of electrical spares for stop gap arrangement till extension of cost cap contract on beml make be1000-1 model, 5 cu.m hydraulic shovel working at ocp3, rg2 on proprietary basis
Tender For tender for rate contract for the period of 2 years for electrical annual maintenance contract with spares for electrical maintenance activities in mngl, pune.
Tender For annual maintenance contract of air conditioning unit including schedule maintenance and optional spares replacement of cao/cn/bnc office complex along with rest houses, cn/mys unit and cn/bnc/fb & local outsourcing the electrical maintenance activity of service buildings, quarters, orhs, switch room being maintained by sse/e/cn/bnc for a period of two years including replacement of electrical items.
Tender For corrigendum : procurement of various spares of hydrogen plant of sgtps, mppgcl, birsinghpur. - particulars as per tender schedule, needle valve for cooling condenser drain line i) one end match from 10 mm ss line ii) other end is size (tag no. 12b1, b2)moc ss 316, fitting of copper tube for filling h2 gas from manifold to h2 cylinder suitable for 150 kg pressure (pegtail), suction hose for h2 compressor as per enclosed drawing, needle valve at gas filling line a&b steam for 10 mm ss tube line before xa, xf, xa filter.make global, mo cbl no. gv54.pnv, 10 m-s6l-p-t-sf, batch no. 404boae heat no. 1163, 6000/psi, moc ss 316, filter body drain valve (airmatic hp filter 350 kg/cm2) size bv bsp-f, water control valve make-aira/asco, dia port bsp-3/4 ,dia orifice -20mm, max working pressure -16 bar,dimensions as per drg ,a=170mm, b=44mm,c=100 mm, function normally closed ,material valve body bronze, pn -16,disk-brass ptfe insert bsp pilot port rod ss 304 ,pilot pneumatic specification-fluid water, temp fluid +5 c to 180 c,ambient +5 c to 60 c (complies with electrical standards nfc 79300), pressure regulator for hydrogen manifold make esab, diaphragms for pneumatic control valve 2 (50 mm) (neoprene rubber) valve make crescent sl no cpl/2 body material cs, diaphragms for pneumatic control valve 3 (75 mm) (neoprene rubber) valve make crescent sl no cpl/2 body material cs, high pressure hose pipe along with connectors at both end size length 1 mtr ( max working pressure -16 bar), ss tube (10 mm od,5 mm id), male connector 10mm od x10mm npt moc ss316, equal union 10mmx10mm od moc ss316, equal tee 10mmx10mmx10mm od moc ss316, nipple 10mmx1 moc ss316, reducer 1/2 x1/4 moc ss316, elbow 90 size 10mmmoc ss316, nut size 10 mmmoc ss316, ferrule in 2 piece10 mm moc ss 316, .
Tender For procurement of electrical / mechanical spares for m/s auma india limited make electrical actuators installed at 210 mw atps, mppgcl, chachai
Tender For custom bid for services - repair of mps 12 unit part no mkld 466229 050 tu sl no 050100745; details of items. (a) description (b) part no mps-12 unit mkld.466229.050 tu (c) make russia (d) si no. 050100745 (e) year of purchase 2016. 2. purpose. the mps-12 unit, pt. no. mkld.466229.050 tu is microcomputer based equipment designed to display aircraft radar data and status of radar equipments on the screen. 3. defects. mps-12 unit, pt. no. mkld.466229.050 tu, si no. 050100745 has been loaded on repair order vide repair order k/ro/k31/2024/2148 dated 06 apr 24 by mo (goa). during function checks of the unit found display becomes white after 5 minutes of operation. further unit confirmed defective during workshop test. 4. repair. (a) identifying the defect utilising the standard electrical and electronic tests/ fault analysis techniques available in the industry. the work is required to be undertaken by qualified technicians. support document for qualified technicians be submitted by the firm. the repair methodology/ repair process undertaken to identify defective component be submitted. (b) replacement of defective bds by utilising mil standard serviceable spares supplied by oem/ oem authorised vendors. suitable certificate of conformity from firm be submitted. further, colour photographs/ video recordings of components replaced during the repairs be submitted with old items replaced. (c) submission of report regarding details of testing, if any, carried out for mps-12 unit in the firm premises. in case such test has been undertaken at firm nromioca thon details of the equipment utilised for testing and qa clearance/ ca applicable) of the test set be submitted. (d) association of firm's engineers for functional, integration anu user acceptance trials at nay (goa). (e) certificate of origin from firm be provided (if imported spares are used). (f) warranty certificates from firm be provided (as applicable). (g) inspection by the yard qa would be undertaken post completion of repairs during user acceptance trials which includes functional checks on aircraft, inspection for transit damage/ visual checks for abnormalities, correctness and completeness of item along with valid documents as per repair order. (h) the item will be tested on sk-801 radar test bench at workshop. if the item fails during testing, the firm agrees to undertake repairs of the item on foc basis irrespective of time elapsed since supply of item to indian navy..
Tender For corrigendum : tender for supply of supply of mechanical and electrical spares for wds6adt type locomotive : : - as per technical specification attached , as per technical specification attached , as per technical specification attached , as per technical specification attached , as per technical specification attached , as per technical specification attached , as per technical specification attached , as per technical specification attached , as per technical specification attached
Tender For supply of electrical spares d d - voltmeter 3.3kv , ampere meter , auxillary contactor 3no 1nc 110v ac , relay overload thermall 80-110a 550v ac , earth leakage relay with cbct 12v 1-750ma , timer relay 550v ac 0-5 min