Get complete information related to latest Test Machine Scrap Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Test Machine Scrap Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Test Machine Scrap Tenders.
Tender For procurement of reagents and chemicals of testing stp treated water samples in water quality monitoring unit, vinay marg, chanakyapuri, new delhi
Tender For corrigendum : providing installation testing and commissioning of a medical grade online double pass reverse osmosis ro plant of 500 liters per hour capacity double pass along with allied works for the hemodialysis unit at sdh parole distt kathua on turnkey basis
Tender For supply installation testing and commissioning of a medical grade online reverse osmosis ro plant of 500 liters per hour capacity double pass along with allied works for the hemodialysis unit in sdh bhaderwah on turnkey basis
Tender For corrigendum : supply and installation of electrical fixtures and gadgets in bolpur ib at bolpur under burdwan zone in west bengal. - supply & delivery of 3 phase 415v fixed speed cassette type air-conditioner machine having cooling capacity not less than 14100w, eer 2.7 to 3.2, noise level not more than 56db. this cassette type air conditioning machine should be fitted with scroll compressors, lcd remote & all other accessories suitable for refrigerant-r32/r410a. (make-o-general /mitsubishi electric/mitshubishi heavy industries as per approved by eic/authority)., supply & delivery of 240v split air-conditioner machine having cooling capacity not less than 6875 w, isser 3.8 to 4.39, bee rating not less than 3 star, noise level not more than 46db. this split air conditioning machine should be fitted with rotary compressors, lcd remote & all other accessories suitable for refrigerant-r32/r410a. (o-general /mitsubishi electric /mitshubishi heavy industries as per approved by eic/authority)., installation, testing & commissioning of the above-said split ac outdoor unit on existing iron structure and indoor unit on wall & mending good the damages as per direction of e.i.c., installation, testing & commissioning of the above-said split ac outdoor unit by fixing iron angle unit on wall & mending good the damages as per direction of e.i.c., supply & installation of extra add-on items- hvac grade 5/8"(for suction) & 3/8"(for discharge) 1.15mm thickness copper refrigerant pipe with 9mm thick nitrile rubber insulation including shaddle,screw, insulation tape, fastner etc for above ac machine as per direction of eic., supply & installation of extra add-on items- hvac grade 5/8"(for suction) & 1/4"(for discharge) copper refrigerant pipe with 9mm thick nitrile rubber insulation including shaddle,screw, insulation tape, fastner etc for above ac machine as per direction of eic., supply & installation of extra add-on items- hvac grade 1/2"(for suction) & 1/4"(for discharge) copper refrigerant pipe with 9mm thick nitrile rubber insulation including shaddle,screw, insulation tape, fastner etc for above ac machine as per direction of eic., supply & laying of 4core 2.5sq.mm 1.1 kv insulation grade sheathed cu cable with gas line as per direction of eic for making interconnection/communication between indoor to outdoor unit of split type ac m/c.(make- havells/finolex/polycab as approved by e.i.c), supply and laying 5/8(20mm) heavy type pvc pipe for water drainage., supplying, fabrication & fixing of iron stand of m.s. angle size (40 mm x 40mmx6mm) for installation of outdoor unit of 4.0 tr split ac incl. drilling 2 nos holes in each angle and horizontal angle angle 40 mm x40mm x 6 mm in each stand. each stand will be properly fixing by supporting angle (25x25x5mm) and flushnut on peripheral wall as per machine configuration & load with adequate service access as per direction of eic, supplying and fixing 415 v four pole mccb of breaking capacity 25ka/35ka with fixed thermal and fixed magnetic / adjustable thermal and fixed magnetic setting in existing dbs / enclosure and necessary connection (a) 160 amp fp mccb (make legrand/crabtree/siemens/l&t/ abb as approved by e.i.c) [d-8/10], supplying and fixing 240/415 v mcb of breaking capacity 10ka & c characteristics on din rail of existing dbs and necessary connection (make legrand/crabtree/siemens/l&t/abb as approved by e.i.c) [d-6/7] (a) 6-32 amp tp mcb, distribution wiring in 1.1 kv single core stranded fr pvc insulated & unsheathed copper wire (brand approved by eic) in 20mm size pvc rigid conduit fr (precision make) incl. necy. fittings as required[e-14] i) 2 x 56/0.3 (4 sqmm) + 1 x 36/0.3 (2.5 sqmm) ecc [e-14/ 1(a)(iii)], s & f 3phase 9-15a , 415 v dol starter (make-l & t ,cat no. ss94351 or equivalent model of abb/siemens as per dierction of e.i.c) to be fixed on wall with all fixing accessories complete as
Tender For corrigendum : partial reconditioning of fs elliott, usa make integrally geared centrifugal air compressor unit 2 - upgradation of spares package of compressorfs elliott make integrally geared centrifugal air compressormodel 3 stage p500 of capacity 3700 cfm @ 8 kg/cm^2gas per the scope without motor the scope includes thefollowing.- the suction filter with suction filter piping.- automatic no loss type drain valve on each cooler- the water header with inlet and outlet connections tointercooler, aftercooler and oil cooler.- motor mounting block arrangement for the main motorfabricated steel oil reservoir/baseplate supports the gearcase, main motor, intercoolers,aftercooler, and lubrication system.all stages of bearings, carbon seals.all instruments.control panel,lubrication system, main oil pump,auxiliary oil pump, check valve, heat exchanger and water system, motor coupling, testing and testing documents. manuals, drawings, p&id
Tender For supply and retrofitting (design, manufacturing, erection, testing & commissioning) of pneumatic trip valves for ab elevation all corner oil guns of 210mw, unit-3 boiler at btps.
Tender For supply and retrofitting (design, manufacturing, erection, testing & commissioning)of pneumatic trip valves for oil guns of 210 mw boilers during unit # 3 coh at ntps, eklahare.
Tender For corrigendum : deployment of radiography team with remote operated gamma radiography shots thickness survey and phase array ultrasonic testing during overhauling of unit 9 2x250mw htps kasimpur
Tender For detailed design, engineering, supply, installation, testing and commissioning of rack and pinion type stack elevator for 2 nos. of 150 meter high reinforced concrete single steel flue chimney unit 1 2 of fgd system at 3 660 mw north karanpura