Web Analytics Made Easy - StatCounter

Tft Monitor Tenders

Get complete information related to latest Tft Monitor Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Tft Monitor Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Tft Monitor Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

CTN :38183227 Due date: 06 Dec, 202406 Dec, 2024 1.22 Crore
Tender For supply of 48 core unarmoured ofc (single mode) , 24 core unarmoured ofc (single mode) , 6 core unarmoured ofc (single mode) , 12u rack server rack- 600mm depth with cable manager-fan, tray-4 and 1pm with individual switch cont , 4u rack server rack- 600mm depth with cable manager-fan, tray-4 and 1pm with individual switch contr , hdpe pipe 40mm , sc sm pigtails , 48 port wall mount liu (light interface unit) with duplex sc couplers , 24 port wall mount liu (light interface unit) with duplex sc couplers , 6 port wall mount liu (light interface unit) with duplex sc couplers , cat-vi utp cable (red colour) , cemented cable route marker with installation , utp cable ties accessories i. e conduits, casing caps, cable tray etc (for utp cable casing and cappi , media converter chasis 16 port with fully poluated 100/1000 mc , media converter 100/1000 mbps , 100/1000 mbps sfp module , layer2 smart switch 16 port , layer2 smart switch 8 port , layer2 smart switch 4 port , fiber distribution frame (fdf) 48 core , fiber distribution frame (fdf) 24 core , ofc splicing and termination at each places (per core) , fixing of rack (12u and 4u) , fixing of fiber distribution frame (fdf) , road cutting and renovation with concrete , hdd (trench less duct type boaring) with ofc laying , installation of cat vi utp cable with conduits , digging, laying, installation and commissioning of ofc at depth of 1.65 mtr with sand and bricks , fiber distribution frame (fdf) 6 core , gi pipe 4" dia bid number/ ( ( ) ): gem/2024/b/5514525 dated/* : 12-11-2024 bid document/ 1 1 / 26

Central Government/Public Sector

CTN :38077013 Due date: 19 Nov, 202419 Nov, 2024 11.46 Lacs
Tender For corrigendum : supply of sapres for bel automation servers at bhubaneshar airport - cpu fan for hpe proliant dl380 gen 10 server , hdd for hpe proliant dl380 gen 10 server , smps module for hpe proliant dl380 gen 10 server , hdd for hpe proliant ml350 gen 10 server , cpu fan for hpe proliant ml350 gen 10 server , smps module for hpe proliant ml350 gen 10 server , nvidia graphics card for hpe proliant ml350 gen 10 server

Central Government And Public Sector

CTN :37930883 Due date: 14 Nov, 202414 Nov, 2024 NA
Tender For corrigendum : supply of server fan module

Central Government/Public Sector

CTN :37927206 Due date: 15 Nov, 202415 Nov, 2024 NA
Tender For corrigendum : supply of tft monitor 19, make- hatteland (part no-navi-0009) , cousor control with key board (part no. navi-0009)

CTN :38050874 Due date: 16 Nov, 202416 Nov, 2024 NA
Tender For supply of repair of led color monitor acer m 200 , repair of laser printer hp m 1005 , repair of multimeter projector mitsubishi dlp , repair of printer epson l 130 , repair of ups 1 kva zebronic , repair of tft monitor lenovo

CTN :38047176 Due date: 18 Nov, 202418 Nov, 2024 NA
Tender For comprehensive annual maintenance contract (camc) of 01 (one) no. allied trolley mounting anesthesia workstation with tft monitor, model-allied medical neptune plus with vaporizer at central hospital blw on single tender basis through oem for 03 years

CTN :37622400 Due date: 22 Nov, 202422 Nov, 2024 50.60 Crore
Tender For corrigendum : construction of 220 160 mva and 132 kv 50 mva gss at hindore rajiasar distt sriganganagar in rajasthan including survey supply of all smaterials erection including civil works testing and commissioning turnkey project - main material/ items, circuit breakers, 220 kv circuit breakers, 220kv circuit breakers (3 ph.) along with support structure, 2500 a, 50 ka, 132 kv circuit breakers, 132 kv circuit breakers (3 ph.) along with support structure, 1250 a, 40 ka, 33 kv circuit breakers, 33 kv circuit breakers (3 ph.) along with support structure, 1250 a, 25 ka, instrument transformers, capacitor voltage transformer, single-phase, 220 kv, 4400 pf cvt, single phase 132 kv , 4400 pf cvt, 33 kv potential transformer, 33/ 3 kv /110-110 3, current transformer (1-phase), 220 kv ct, 1000/1 a, 5c, 132 kv ct, 1000/1 a, 3c, 500/1 a, 3c, 33 kv ct, 1000/1 a, 4c, 500/1a, 2c, c&r panels & sas system (complete in all respect, refer section-v a, b, part-iii, volume-ii), new substation, control panel for 220 kv transformer (220 kv side) type: sas-thcb, relay panel for 220 kv transformer (for both hv & mv) type: sas-thrb, control panel for 220 kv feeder type: sas-fcb, relay panel for 220 kv feeder type: sas-frb, control panel for 220 kv bus coupler type: sas-bccb, relay panel for 220 kv bus coupler type: sas-bcrb, 220 kv busbar protection relay panel type: sas-bbrb, control panel for 220 kv transformer (132 kv side) type: sas-tlcb, relay panel for 220 kv transformer (132 kv side) type: sas-tlrb, control and relay panel for 1x 50/31.5/25 mva, 132/33 kv power transformer type sas-tcra, control panel for 132 kv feeder type sas-fca, relay panel for 132 kv feeder type sas-fra, control and relay panel for 132 kv bus-coupler type sas-bcra, control and protection panel for 33 kv feeder (i/c, o/g)/bus-coupler/ capacitor bank [for twin feeder/bay] type-fcrd, station hmi [industrial grade computer with 21"tft monitor as per specification requirements], station hmi (hot standby)[industrial grade computer with 21"tft monitor as per specification requirements], hmi view node[industrial grad computer with 21"tft monitor as per specification requirements], a3 size b&w laser printer, substation automation system network panel type sas-nw, modems (both sending and receiving end) for communication to rcc & sub sldc for plcc], data concentrator unit (dcu) at substation for ras mounted in suitable enclosure & fully wired, software: application as well as system software as per specification requirements for various hardware elements for meeting of functional requirement of the specification., substation auxiliary monitoring panel type sas-samp, other items:, fiber optic cables, connectors, ethernet cables, jack panels connectors, patch cords etc. for completing the substation lan as per specification requirements., transducers, sensors etc. (if not considered in the respective equipment/ items) for accumulating monitoring data as per the specification requirements for switchyards., surge arresters, 220 kv la, 132 kv la, 33 kv la, substation lt transformer, 33/ 0.433 kv, 250 kva lt transformer complete with all accessories, fittings, terminal connectors etc as specified filled with transformer oil, batteries & battery charger, batteries (sizing shall be as per requirement of technical specification), 220 v [min. 600 ah], 48 v [min. 600 ah], battery charger system, 220 v float and boost, 50 v float and boost, lighting system, outdoor lighting & other works, lighting fixture type fl-1, lighting fixture type fl-2, outdoor receptacle, type-rp, type-ro, substation premises lighting, lighting poles, type-l1, type-d1, street lighting type-sl-l1 for mounting on poles, street lighting type-sl-d1 for mounting on poles, sub-lighting boxes/panels type -slp at lighting mast and other loaction as designated complete with all controgears and accessories, items etc., lighting panel type acp-2 as per technical specification, lighting panel typ

CTN :37622467 Due date: 22 Nov, 202422 Nov, 2024 46.45 Crore
Tender For corrigendum : construction of 220/132 kv, 1x160 mva and 132/33 kv, 1x40/50 mva gss at 220 kv gss kolayat (distt-bikaner) in rajasthan including survey, supply of all equipments/materials, erection (including civil works), testing and commissioning (turnkey ) - main material/ items, circuit breakers, 220 kv circuit breakers, 220kv circuit breakers (3 ph.) along with support structure, 2500 a, 50 ka, 132 kv circuit breakers, 132 kv circuit breakers (3 ph.) along with support structure, 1250 a, 40 ka, 33 kv circuit breakers, 33 kv circuit breakers (3 ph.) along with support structure, 1600 a, 31.5 ka, instrument transformers, capacitor voltage transformer, single-phase, 220 kv, 4400 pf cvt, single phase 132 kv , 4400 pf cvt, 33 kv potential transformer, 33/ 3 kv /110-110 3, current transformer (1-phase), 220 kv ct, 1000/1 a, 5c, 132 kv ct, 1000/1 a, 3c, 500/1 a, 3c, 33 kv ct, 1000/1 a, 4c, 500/1a, 2c, c&r panels & sas system (complete in all respect, refer section-v a, b, part-iii, volume-ii), new substation, control panel for 220 kv transformer (220 kv side) type: sas-thcb, relay panel for 220 kv transformer (for both hv & mv) type: sas-thrb, control panel for 220 kv feeder type: sas-fcb, relay panel for 220 kv feeder type: sas-frb, control panel for 220 kv bus coupler type: sas-bccb, relay panel for 220 kv bus coupler type: sas-bcrb, 220 kv busbar protection relay panel type: sas-bbrb, control panel for 220 kv transformer (132 kv side) type: sas-tlcb, relay panel for 220 kv transformer (132 kv side) type: sas-tlrb, control and relay panel for 1x 40/50 mva, 132/33 kv power transformer type sas-tcra, control panel for 132 kv feeder type sas-fca, relay panel for 132 kv feeder type sas-fra, control and relay panel for 132 kv bus-coupler type sas-bcra, control and protection panel for 33 kv feeder (i/c, o/g)/bus-coupler/ capacitor bank [for twin feeder/bay] type-fcrd, station hmi [industrial grade computer with 21"tft monitor as per specification requirements], station hmi (hot standby)[industrial grade computer with 21"tft monitor as per specification requirements], hmi view node[industrial grad computer with 21"tft monitor as per specification requirements], a3 size b&w laser printer, substation automation system network panel type sas-nw, modems (both sending and receiving end) for communication to rcc & sub sldc for plcc], data concentrator unit (dcu) at substation for ras mounted in suitable enclosure & fully wired, software: application as well as system software as per specification requirements for various hardware elements for meeting of functional requirement of the specification., substation auxiliary monitoring panel type sas-samp, other items:, fiber optic cables, connectors, ethernet cables, jack panels connectors, patch cords etc. for completing the substation lan as per specification requirements., transducers, sensors etc. (if not considered in the respective equipment/ items) for accumulating monitoring data as per the specification requirements for switchyards., surge arresters, 220 kv la, 132 kv la, 33 kv la, substation lt transformer, 33/ 0.433 kv, 250 kva lt transformer complete with all accessories, fittings, terminal connectors etc as specified filled with transformer oil, batteries & battery charger, batteries (sizing shall be as per requirement of technical specification), 220 v [min. 600 ah], 48 v [min. 600 ah], battery charger system, 220 v float and boost, 50 v float and boost, lighting system, outdoor lighting & other works, lighting fixture type fl-1, lighting fixture type fl-2, outdoor receptacle, type-rp, type-ro, substation premises lighting, lighting poles, type-l1, type-d1, street lighting type-sl-l1 for mounting on poles, street lighting type-sl-d1 for mounting on poles, sub-lighting boxes/panels type -slp at lighting mast and other loaction as designated complete with all controgears and accessories, items etc., lighting panel type acp-2 as per technical specifica
 Loading, Please wait...

Connect us via What's Up