Get complete information related to latest Thermal Conductor Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Thermal Conductor Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Thermal Conductor Tenders.
Tender For supply of 25 sq.mm, yellow colour, electron beam irradiation curing process or chemical curing process thin walled flexible elastomeric cable with copper conductor suitable for rolling stock application conforming to rdso spec.no.elrs/spec/elc/0019, rev.4, feb-2018, 1.8 kv grade. note: (1) item/type/model/make/brand from the manufacturer/suppliers as approved by rdsoshall only be considered. (2) cables shall be supplied in coils of 500 metres length and leftoverquantityin multiples of 100 metres with a tolerance of +/-5% on the length. (3) firm shall indicate the curing process(e-beam irradiation or chemical curing)in their offer. [ warranty period: 30 months after the date of delivery ]
Tender For supply of thin walled e-beam irradiated flexible cable with copper conductor, working voltage above 750 v & upto 1.8/3.0 kv grade, size: 25 sq mm as per rdso specn. no:elrs/spec/ elc/0019 (rev-4) of feb-2018 or latest in equal quantity of red, yellow, blue & black colour. material must be procured from rdso approved sources only vide rdso item id:3100270. [ warranty period: 30 months after the date of delivery ]
Tender For bid to ras supply of heavy duty single compression cable d d - supply of heavy duty single compression cable glandcable suitability 4 core 2.5 sq. mm armoured cable , supply of heavy duty single compression cable gland cable suitability 4 core 16 sq. mm armoured cable , supply of pvc insulated single core flexible multi stranded copper conductor frls cable size 2.5 sq. mm , supply of pvc insulated single core flexible multi stranded copper conductor frls cable size 16 sq. mm , supply of mild steel ms saddles cable suitability suitable for 16 sq. mm xlpe cable saddle size 25 mm , supply of mild steel ms saddles cable suitability suitable for 16 sq. mm xlpe cable saddle size 25 mm saddle size 19 mm , tin plated copper conductor earthing strip , supply of non-insulated pin type heavy duty tubular terminal type pin type conductor size 2.5 sq. mm , supply of non insulated flat type heavy duty tubular terminal type flat type conductor size 2.5 sq. mm , supply of non insulated pin type heavy duty tubular terminal type pin type conductor size 2.5 sq. mm conductor size 16.0 sq. mm , supply of non-insulated pin type heavy duty tubular terminal type flat type conductor size 16.0 sq. mm , supply of ferrule marker marker c conductor size suitability 1.5 2.5 sq. mm , supply of ferrule marker marker m conductor size suitability 1.5 2.5 sq. mm , supply of ferrule marker marker 0 conductor size suitability 1.5 2.5 sq. mm , supply of ferrule marker marker 1 conductor size suitability 1.5 2.5 sq. mm , supply of ferrule marker marker 3 conductor size suitability 1.5 2.5 sq. mm , supply of ferrule marker marker 4 conductor size suitability 1.5 2.5 sq. mm , supply of ferrule marker marker 5 conductor size suitability 1.5 2.5 sq. mm , supply of ferrule marker marker 6 conductor size suitability 1.5 2.5 sq. mm , supply of ferrule marker marker 7 conductor size suitability 1.5 2.5 sq. mm , supply of ferrule marker marker 8 conductor size suitability 1.5 2.5 sq. mm , supply of ferrule marker marker 9 conductor size suitability 1.5 2.5 sq. mm , supply of ferrule marker marker c conductor size suitability 16 25 sq. mm , supply of ferrule marker marker m conductor size suitability 16 25 sq. mm , supply of ferrule marker marker 0 conductor size suitability 16 25 sq. mm , supply of ferrule marker marker 1 conductor size suitability 16 25 sq. mm , supply of ferrule marker marker 2 conductor size suitability 16 25 sq. mm , supply of ferrule marker marker 3 conductor size suitability 16 25 sq. mm , supply of ferrule marker marker 4 conductor size suitability 16 25 sq. mm , supply of ferrule marker marker 5 conductor size suitability 16 25 sq. mm , supply of ferrule marker marker 6 conductor size suitability 16 25 sq. mm , supply of ferrule marker marker 7 conductor size suitability 16 25 sq. mm , supply of ferrule marker marker 8 conductor size suitability 16 25 sq. mm , supply of ferrule marker marker 9 conductor size suitability 16 25 sq. mm , supply of ladder type frp fibre reinforced plastic cable tray size 300 150 mm width side height , supply of reducer suitable for ladder type frp cable tray parent tray size 300 150 mm item no. 1 reduced tray size 200 150 mm , supply of coupler for ladder type frp cable tray material frp fibre reinforced plastic
Tender For bid to ras supply of electrical item c c - flexible copper conductor , xlpe aluminium armoured power cabl , changeover switch 100 amp , axial panel cooling fan , 25 amp industrial plug and socket single phase , 100w led flood light , switch is 3854 and 16 amp socket outlet , screw driver tools kit se
Tender For bid to ras supply of flexible copper trailing cables d d - item 10 , item 20 , item 30 , item 40 , item 50 , item 60 cable,trg,atc,3.3kv gr,3.5cx50mm2,is9968 size & tvpe 3.5cx50 sq. mm 3.3 kv grade flexible atc conductor of class-s, epr le-3, insulated &black hofr nbr pvc type se-4 sheathed flexible trailing cable suitable for reeling/un-reeling operation. cable type- flexible, standard: is 9968(part 2) 2002 d.c. resistance at 20deg. c (ohms/km) power core max- 0.393 earth core max - 0.795. annealing test in %- (before stranding) 13.5 %. per sulphate test in g/m2- max. 5.00. conductor screeninq power core only material approx thickness mm - extruded semiconducting compound/ extruded semi conducting tape- 0.80. conductor material: annealed tinned copper, 6.6 klv grade, cable type: flexible, standard: is 9968(part 2) 2002 tests on insulation thickness (nom) mm core ldentification - power core-2.20 colour rpct red, yellow & blue for power cores & green for earth core tensile strength before ageing n/mm2- min.4.20 % variation after ageing (air oven)- max. +-30% % variation after ageing in (air-bb)- max. +- 30%. elongation before ageing in % - min.200% % variation after ageing (air oven)- max. +- 30% % variation after ageing in (air-bb)- max. +- 30%. hot set test hot set elongation- 175% permanent set 15%. lnsulation resistance constant (min.) m ohm km. at 27deg.c- min. 3670 at 90 deg.c-min 3.67. thick of lnner sheath min 2.00 mm. rein forcement- open braid of textile material physical test on outer sheath thickness (nom) / min mm- 3.50/ 2.60 colour black, over all diameter of cable mm- 52.00+-3.00. tensile strength ) /bid number : gem/2025/b/6811700 * /dated: 24-10-2025 & & / bid document 1 / 22 before ageing n/mm2 - min. 11.0 at 2oo elongation 4n/ sq. mm. % variation after ageing in (air-bb)-max. +- 50% elongation before ageing in %- min.250% % variation after ageing in (air-bb)- max. + 50%. hot set test hot set elongation- max.175% permanent set- max 15. oil resistance test variation in % in tensile strength- max. +-40% variation in % in elongation-max. +-40%. tear resistance in n/mm - min.5.0. flammability test period of burning after removal of flame- max. 60 sec. min unaffected portion from the lower edge of the top clamp - min 50 mm. test high voltage at room temp- 10 kv ac for 4 hours. water absorption test increase in capacitance 1 to 14 days max- 6% 7 to 14 days max- 2.5%., control trailing cable 12 c x 2.5 3 p x 1.5 (pair screened) 2 voltage grade 1.1 kv 3 reference standard generally confirming to is: 9968 (part- 1)1998 4 conductor a. material to is:8130/84 annealed tinned copper b. nominal area of cross section(sq. mm) i)-unscreened core (sq. mm.) 2.5 ii) - screened pair (sq. mm.) 1.5 c. flexibility class as per is:8130/84 class-5 d. maximum dc resistance of conductor at 20 deg. c i)-unscreened core (ohms/km) 8.21 ii)- screened pair (ohms/km) 13.7 5 insulation i) material epr type ie-2 to is:6380/84 ii) nominal thickness (mm) 1.0 6 two cores of 1.5 sq. mm. size twisted together to form a pair yes. 7 individual pair screening each pair of 1.5 sq. mm. size taped with rpct, screened with 0.2 mm nom dia of annealed tinned copper wires braid, taped with melinex tape. yes. 8 no of cores / pair i)-unscreened cores 12 ii)-screened pairs 3 9 identification of power cores by number printing on cores. 10 laying up (i) three screened pairs laid up together, taped with rubber proofed cotton tape to form group as "a" (ii) 12 unscreened control cores laid up together around group as "a" of screened pairs and taped with rubber proofed cotton tape applied with open spiral. 11 inner sheath a) material to is: 6380/84 hd hofr csp type se-4 b) minimum thickness (mm) 1.6 12 an open braid of nylon cord reinforced in between inner and outer sheath. yes. 13 outer sheath a) material to is: 6380/84 hd hofr csp type se-4 b) nominal thickness (mm) 2.5 14 nom. overall diameter of cable (mm) 33.0 tolerance on nom. overall dia
Tender For corrigendum : supply of supplying of 1.5 tr nominal capacity invertor type metal body , installation, testing and commissioning of of 1.5 tr inverter type ductable air cooled split ac unit as per item no.1 above in equipment room , providing and fixing heavt duty powder coated m s stand of suitable size made out of suitable guage ms shee , supply and fixing of 3 core 2.5 sq mm control cum transmission wiring and ac power supply cable of shielded copper conductor for looping between indoor and outdoor , supply and fixing of 4 core 1.5 sq mm control cum transmission wiring and ac power supply cable of shielded copper conductor for looping between indoor and outdoor , supply installation testing and commissioning including vaccumiazation and nitrogen testing of , supply installation testing and commissioning including vaccumiazation and nitrogen , supplying and fixing of 25 mm sizes of rigid upvc piping from outlet socket of ac unit complete with elbow , supplying and fixing dp sheet steel enclosure on surface or recess along with 25 or 32 a 230 v c curve dp mcb , supplying and fixing 5 amps to 32 amps rating, 240 or 415 volts c curve miniature circuit breaker suitable for inductive load of single pole and neutral , providing and fixing supply air grills of powder coated aluminum construction having a free area of not less than 70 percent without volume control dampers , supplying and installing of 150 mm width 50 mm depth 1.6 mm thickness nominal size of perforated hot dipped galvanised iron cable tray
Tender For supply of thin walled e-beam irradiated flexible cable with copper conductor, working voltage above 750 v & upto 1.8/3.0 kv grade, size: 95 sq mm as per rdso specn. no:elrs/spec/ elc/0019 (rev-4) of feb-2018 or latest in black colour. material must be procured from rdso approved sources only vide rdso item id:3100270. [ warranty period: 30 months after the date of delivery ]
Tender For corrigendum : supply of service connector of 2.5 sq.mm cross section for connecting railway carriage fan and light fittings as per item no.wago make or equivalent as per the technical data: (1) type of wiring: side-entry wiring. (2) total number of connection points: 2. (3) total number of potentials: 1. (4) connection technology: cage clamp. (5) actuation type: push-in. (6) connectable conductor material: copper.(7) solid conductor: 0.5 - 2.5 mm 2/20 - 16awg. (8) fine stranded conductor: 0.5 - 2.5 mm 2/20 - 16awg. (9) strip length: 9 - 11mm/ 0.35 - 0.43 inch. (10) width: 8mm/ 0.315 inch. (11) height: 15.5mm/ 0.61 inch. (12) depth: 42 mm/ 1.654 inch. (13) colour: grey. (14) fire load (mj): 0.099 (mj). (15) weight(g): 5(g). this item has no approved sources in rdso/icf/rcf, hence to be procured from open market i.e. oem or its authorized dealers. [ warranty period: 30 months after the date of delivery ]
Tender For supply of tubular crimping socket for 150mmsq e beam cable conductor made of copper as per rcf spec no. edts200 rev 0 am-2 corr 3 item 1 suitable for lhb ac coaches. [ warranty period: 30 months after the date of delivery ]
Tender For supply of tubular crimping socket for 150mmsq e beam cable conductor made of copper as per rcf spec no. edts200 rev 0 am-2 corr 3 item 1 suitable for lhb ac coaches. [ warranty period: 30 months after the date of delivery ]