Get complete information related to latest Thermo Resistor Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Thermo Resistor Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Thermo Resistor Tenders.
Tender For annual maintenance contract for all electrical systems of ht/lt lines and equipment of 33/11/6.6 kv substation and lighting installations of powerhouse and colony for two years at ttps lalpania.
Tender For shifting, erection testing and commissioning of emergency pumping equipments such as transformers ht and lt panel boards, cables, motors, pumps and connected delivery piping at singoor dam and dismantling and shifting of emergency pumping equipment from singoor campus to peddapur campus after completion of emergency pumping at singoor under eam cell-ii, peddapur, transmission division no.ii, patancheru
Tender For corrigendum : aoh of electrical equipment and auxiliaries of sstpp unit-1 of 2x600mw, sstpp, mppgcl, khandwa. - generator, misc works in generator overhauling, h2 purging after unit shutdown & h2 refilling before of unit light up., transformers, general overhauling of ht transformers, generating transformer(work description as detailed intender schedule), station transformer (work description as detailed intender schedule), inter-connecting transformer (work description as detailed intender schedule), unit auxiliary transformer (work description as detailed intender schedule), neutral grounding panel ( gen., gt, st, uats) {(work description as detailed intender schedule)}, general overhauling of lt transformers, lt dry type transformers (work description as detailed intender schedule), lt oil filled transformers (work description as detailed intender schedule), switchyard, breaker, isolators ,earth switch, bay equipments (cleaning & terminal tightness), bus ducts (work description as detailed intender schedule), 21/ 15.75 kv gen bus duct, 11 kv uat/st bus duct, 6.6 kv uat/st bus duct, lt transformer bus duct, esp, ltmsb & acp buses , ec panels & heater work (as per scope of work), ltmsb & acp breakers (as per scope of work), ltmsb & acp modules(as per scope of work)eerm=80 , cerm=80, gdrm=8, fields= 80, vfd supply=4, lighting supply & etc. = 25(approx), ht switchgear (11 kv/ 6.6 kv), bus cleaning , tightness & complete inspection of all buses., breaker cleaning, tightness & operation checking, bop switchgears panel / local control panels / wall mounted panels and 415v lt swbd/ mcc/acdb/dcdb switchgear panel, bus cleaning , tightness & complete inspection of all buses. breaker cleaning, tightness & operation checking, power house lighting & power supply, cleaning , tightness & complete inspection of all lightning transformers & ldb, providing power supply as per site requirement & for other maintenance work of bmd,tmd etc., ht motors, servicing of ht motors, ht motor cooler (general inspection & cleaning), lt motors servicing, motors above 40 kw, motor 40 kw to 11 kw, motors 10 kw to 5.5 kw, motors 5 kw to 1.1 kw, motors 1 kw and below, esp lt motors 1 kw and below, lt motor overhauling, motors above 40 kw(machining), motor 40 kw to 11 kw, motors 10 kw to 5.5 kw, motors 5 kw to 1.1 kw, motors 1 kw and below, servicing of dc bus, cleaning/servicing of 220 v dcdb buses & modules, servicing of soot blowers, servicing of soot blower motor 1 kw & below, servicing of soot blower panel/modules
Tender For corrigendum : supply of supply of auto electrcial spares for hem equipment : : - lt wire 6mm , lt wire 8mm , cable,3mm,auto , pvc insl plain stripped auto cable 4mm , cable,flexible,5mm, l t auto , 10 mm ring type copper lug , 2 mm ring type copper lug , 3 mm ring type copper lug , 4 mm ring type copper lug , conduit pipe 1 , cable ties size 200mm- packet of 100 pcs , cable ties size 300mm-packet of 100 pcs , cable ties size-500 mm packet of 100 pcs , pvc elect insulation tape,1.80cm wx6m l , rustlick 631,370ml , electronic component cleaner co2 , cabin fan 24v dc 20
Tender For tender for supply of deisgn engineering and supply of electrical instrumentation and civil works : : - design and engineering of imcc panel 2 nos and vfds , design and engineering of apfc and hvac , design and engineering of apfc and field instruments , design and engineering of cables and termination , design and engineering of earthing of imcc , field equipments and soil testing , design and engineering of civil buildings and structure foundations , design and engineering of imcc building with earthing system , design and engineering of structural works for cable laying for both incoming and outgoing cables , design and engineering of lighting system of imcc building , equipment locations at ccr ground floor and along the structural path for cable route , supply of imcc panels , vfd panels , supply of apfc panels , hvac system , supply of mldb lighting distribution boards , lighting material including db , light fittings , and all related accessories or wiring material etc , supply of field instruments and necessary piping materials as required , supply of plc , supply lt cables and other related accessories for electrical , termination material and other instrumentation cables as required , supply of cable trays for electrical and instrumentation , supply of all earthing material as per is 3043 for imcc and connection to earth pits for motors , panels etc , supply of fire detection and alarm system for building and cable alley area along with integration and display at fire station/existing control centre , erection , testing , commissioning , and handover of equipments of imcc panels and vfd panels , erection , testing , commissioning , and handover of equipments of apfc panels and hvac system , erection , testing , commissioning , and handover of equipments of lighting system as per above supply , erection , testing , commissioning of earthing system , erection , testing , commissioning of field instruments and necessary piping materials etc as required , erection , testing , commissioning and handover of plc , erection , laying , testing and commissioning of lt cables ( cable terminations wherever required along with necessary accessories is in the scope of the contractor) for electrical and instrumentation , erection , testing and commissioning of cable trays for electrical and instrumentation , erection , testing and commissioning of fire detection and alarm system for building and cable alley area along with integration and display at fire station/existing control centre , substructure excavation , foundation works (footings , columns up to plinth level) , dpc (damp proof course) , and backfilling. , superstructure columns , beams , slabs , brickwork/masonry for all floors above plinth level , and formwork up to ground floor , finishes plastering , flooring (tiles , marble) , painting , wall cladding , and other interior/exterior finishes , plumbing works , fixing of doors up to ground floor. , superstructure columns , beams , slabs , brickwork or masonry for all floors above plinth level , and formwork for subsequent floors as per approved design , finishes plastering , flooring (tiles , marble) , painting , wall cladding , and other interior/exterior finishes , plumbing works , fixing of doors for subsequent floors as per approved design , supply and erection of structural works for cable laying for both incoming and outgoing cables
Tender For "design, supply, erection, testing and commissioning of 25kv,50hz, single phase ac traction overhead equipment with 65sq.mm caternary wire and 107sq.mm hdg copper contact wire, lt supply transformer stations including modifications to the existing ohe in connection with proposed bye pass line with ror between mustabada (mbd) and rayanapadu (ryp) - (balance works) in vijayawada division of south -central railway" reg.
Tender For corrigendum : sitc of agri food bio mug turnkey pilot plant setup d d - process equipment with automation , civil works retrofit , civil external misc. incl , hvac works , hvac controls bms works , metallic insulated panels and cleanroom panel systems design , compressor and drier , electric boiler , thermic fluid heating system , water cooled brine chiller , water cooled chiller , cooling tower , pumps , water ring vacuum pump , chilled water piping for process and hvac , chilled brine piping for process , cooling water generation and distribution piping , compressed air instrument air generation and distribution piping , vacuum distribution , low pressure steam lpst piping distribution , high pressure steam hpst piping distribution , thermic fluid piping distribution , soft water distribution , nitrogen gas distribution , carbon di oxide gas piping distribution , oxygen gas piping distribution , structural steel supports works , equipment erection , drain piping , process piping , process cip piping , electrical lt systems , electrical ht works , fire alarm system , public address system , access control system , door interlocking system , closed circuit televisison cctv , gas detection system , networking voice and data system design , fire protection system , dismantling works
Tender For - arc of electrical material. - electrical work :, providing & fixing of ik08, ip 66 protected led street light luminaire on existing bracket/pole. fixture made of powder coated single piece pressure die cast aluminum material with heat dissipation fins on housing with uv stabilized pc (uv stablization report submitted for uv cover ) /toughened glass cover and secondary lens on each led & should be smd type of 3 to 5 watt each . the system efficacy >=125 lm/ wt and potted driver & has a unique bis r number with input voltage ac 120 to 270 v ac with high voltage cutoff @>=300 v ac and auto resetting safety , power factor >0.95 driver efficiency >85% ,thd(i) 10% humidity 10% to 90% rh working temp -5c to 45c . driver current 750ma. the luminaire shall be bis certified and trade mark certified. life expectancy equal or more than 50000 burning hrs with minimum 70% lumen maintened , cri >70 and cct 5700k +355k. surge protection shall be min 4 kv internal and min 10 kv external inside driver compartment. driver should be phase to phase protection of 440 v for 4 hrs. manufactures word mark/name engraved/embossing on die cast housing to allow traceability/authenticity. fixture shall be as per is 10322 complianced.oem must have its own in house nabl lab setup for all testing facilities for led fixtures. (lm79/lm80) certificate/ report with liable warranty of product/accessories from oem shall be submitted. all as per pre approved by engineer in-charge. for additional technical parameters of products/ work , refer annexure "a" attached with this bsr . led street light fixture with minimum lumen output 5600 lm, supplying and drawing of xlpe insulated lt aerial bunched aluminium conductor cable confirming to is 14255/1995 and is 398 (pt-4)/ 1994 and as per discom specs. on existing cross arms through i hook with all necessary t&p required including binding and twisting etc. complete in all respect as required. all as per pre approved by engineer in-charge. for additional technical parameters of products/ work , refer annexure "a" attached with this bsr . 1 x 25 sq. mm. + 1x25 sq. mm. (insulated), supply and fixing of 11 kv pin insulator confirming to is:731:1971 with latest ammendment on existing bracket including all accessories like ms forged hot dipped gi pin confirming to is 2486(part-i)/1993 & is:2486 (part-ii)/1989 with latest amendment, and as per latest discom specs. etc. as required. all as per pre approved by engineer in-charge.for additional technical parameters of product / work refer annexure a attached with this bsr, sitc of ip-42 and general construction confirming to is:8623 : 1993, wall/ free standing floor mounted dust and vermin proof compartmentalised cubical panel as specifications and other parameters required as per point (a) ,(b), (c),(d), (e), (f), (g), (h) as below:-(a)thickness of crca sheet shall be 2.0 mm, cable alley compartments having concealed hinged type doors with key type lock with / without detachable extension type structure. removable 3 mm. thick sheet steel gland plates with appropriate size of knockouts for cables shall be provided(b)complete panel shall undergo a process of degreasing, water rinsing, activation, derusting, pickling in acid bath, phosphatising & shall be subjected to nine tank process and then powder coated with approved shade of minimum 70 microns on both side of panel. the panel having pe foam/ neoprene rubber gasket of not less than 3mm thickness ,required hardware , concealed hinged door with key type locking arrangement for equipment/switchgear earthed with 2.5 sq.mm braided copper wire.[c) interconnection between bus bar and switchgears /cable shall be rigidly supported and made out by flexible copper wires (up to 63 amp ) and by solid bus bar (>63 amp ) . control wiring will be carried out with 1.5 sq.mm, earth wire with 2.5 sq.mm and ct with 2.5 sq.mm flexible copper wire only. all joints / interconnections of copper bus bar shall be dully tinned . c