Get complete information related to latest Tint Meter Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Tint Meter Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Tint Meter Tenders.
Tender For supply and installation of digital automatic lovibond tinto meter model fx to ops whitefield bangalore - digital automatic lovibond tinto meter model fx
Tender For purchase of chem lab equipments - wire gauze--, water bath rectangular stainless steel thermostat--, water bath copper with concentric circles 6 inch dia--, wash bottle plastic 250ml--, tripod stand--, tongs 8 inch dia--, tongs 6 inch dia--, test tube stand --, test tube holder--, suction pump --, semi micro spatula--, pipette stand vertical--, pipette pump 10ml--, magnetic retriever--, magnetic bits--, magnetic stirrer 1000ml--, magnetic stirrer 500ml--, iron stand with base and clamps --, hot plate with magnetic stirrer--, hot plate rectangular 1kw--, heating mantle 1000ml--, heating mantle 500ml--, glass electrodes--, crucible filter--, filtration stand p p ring--, electronic balance sartorius 100 microgram weighing capacity 220g--, digital balance 100 microgram--, electrical bunsen burner--, electric centrifuge machine--, dessicator with lid--, digital uv vis spectrophotometer 340nm to 960nm--, digital potentiometer--, digital photoelectric colorimeter 8 filters--, digital ph meter--, digital conductivity meter with cell--, condenser clamps four finger to hold condenser with base hand covered with rubber sleeves--, retort ring clamps for separating funnel 3 inch dia--, centrifugal machine hand driven--, calomel electrodes- -, burette stand with fisher clamp--, bunsen burner brass--
Tender For supply, installation and trials of laboratory instruments equipment apparatus with training for quality control ii division at siliguri, p.w.(roads) directorate - nomenclature of machine/instrument and work required: supply, of only vacuum pump cum controller required for existing digital 4 station vacuum indicator for absolute viscosity test. the same will have to he installed on the existing machine and after installation, necessary trials are to be carried out. relevant is code: is: 1206: 2022 (part ii). specification: the pump connected with the vacuum system should be capable of maintaining a vacuum within 2 0.05 cm of the desired level up to and including 30 cm of mercury, and should have the capability of holding the desired pressure throughout the period of a particular test. the pump should have both analogue (with divisions of 0.05 cm of hg) and digital pressure gauge (capability of displaying minimum of 0.05 cm of hg). the vacuum pump controller should be supplied with a 4-position manifold to apply vacuum simultaneously up to four positions and perform viscosity determinations. equipped with dedicated on/off switches for each position and supplied with blue silicon tubing. the pump should have the capability of withholding the pressure set for tests and also maintain it throughout the test. vacuum pump should be the part of vacuum system [pump should be inbuilt with in the vacuum system along with analogue and digital display of vacuum). note: 1. calibration certificate will have to be furnished and should be valid for atleast 10 months from the date of supply 2. necessary tests and trials will have to be carried out to the satisfaction of engineers of q.c.-ii division at siliguri. 3. two year comprehensive warranty of total system from the date of satisfactory completion of onsite installation, commissioning and training of the instrument., nomenclature of machine/instrument and work required: supply, installation of u-tube, modified reverse flow viscometer for opaque liquid required for kinematic test of bitumen. details: tube no. 6 & 7 with 01 no. stand each. relevant is code: is 1206 (part 3): 2021 specification: note: 1. calibration certificate will have to be furnished and should be valid for atleast 10 months from the date of supply. 2. necessary tests and trials will have to be carried out to the satisfaction of engineers of qc-ii division at siliguri. 3. two year comprehensive warranty of total system from the date of satisfactory completion of onsite installation, commissioning and training of the instrument., nomenclature of machine/instrument and work required: supply & installation of serological water bath. specification: the bath should have double walled structure, having facility of digital controller cum indicator. the bath should have stirring arrangement. inside wall should be of stainless-steel seamless ss 304 seamless, min. thickness 1.0 mm, with rounded corners for easy cleaning with proper drainage system having ptfe valve and hose pipe (15mm inner dia. min). outer wall to be of ms and properly insulated with cfc-free high-density insulation. minimum temp. range is 5°c to 95°c, 20.2°c. size should be minimum 28 l: -600 w 400d 350 h mm; for 8 standard racks, with adjustable height, compatible with common test tubes (10-50 mm dia.) and other bottles/beakers. note: 1. calibration certificate will have to be furnished and should be valid for atleast 10 months from the date of supply. 2. necessary tests and trials will have to be carried out to the satisfaction, nomenclature of machine/instrument and work required: supply & installation of burette stand with clamp specification: boss head & rod (with stainless steel corrosion resistant rod (length 18") the rod diameter is 1 cm and solid black coated support stand base (6"x4"). should be made of high-quality anti-corrosion & rust-proof stainless steel. the base should be padded to prevent scratches on the surface and better gri