Web Analytics Made Easy - StatCounter

Titrator Tenders

Get complete information related to latest Titrator Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Titrator Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Titrator Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

CTN :41288348 Due date: 16 Aug, 202516 Aug, 2025 NA
Tender For supply of calibration of various mechanical and electrical instruments d d - calibration of pressure gauge , calibration of vaccum gauge , calibration of compound gauge , calibration of pt , calibration of diff. pg , cal. of pres gauge to qc lab , cal. of vaccum gauge to qc lab , verification to pressure switch , cal. of water meters upto 4 inch , cal. of water meters 4 to 8 inch , ac ammeter calibration , ac voltmeter calibration , digital ammeter calibration , clamp meter calibration , dig earth resistance tstr to cali , dig frequency meter cali , winding temp indicator cali , oil temp indicator cali , multi function meter cali , lux meter calibration , digital voltmeter calibration , dig power factor meter cali , dig insulation tester cali , mobilisation charges , sply ss pg from 0 to 16 kg , sply ss pg from 0 to 25 kg , sply ss diff pg from 0 to 2kg , sply ss vg from 0 to 760mm hg , sply ss cg from 0 to 10 kg , sply ss ps from 1.6 to 10 kg , sply ss pg from 0 to 10 kg

CTN :41288581 Due date: 12 Aug, 202512 Aug, 2025 NA
Tender For supply of miscellaneous electrical items supply and service - supply of 25 mm flexible braided copper of half meter length , fixing of 25 mm flexible braided copper , supply of 22kv do fuse bottom metal part , fixing of 22kv do fuse bottom metal part , supply of 22kv do fuse top metal part , fixing of 22kv do fuse top metal part , supply of para compound tape for mcc busbar one roll , wounding and fixing of para compound tape for mcc busbar one roll , supply of 22kv fuse rod with fuse wire 40 amps , fixing of 22kv fuse rod with fuse wire 40 amps , supply of 400a male contactor with arcing horn , fixing of 400a male contactor with arcing horn , supply of porcelain insulator with ss bolt and nut with double washer , fixing of porcelain insulator with ss bolt and nut with double washer , relay testing- bimetallic strip type , dg set protection relay testing cdg31 relay and earth fault relay , 22kv ht vcb panel relay testing , calibration of ammeter , calibration of energymeter , acb servicing- 1000 amps , supply and fixing of 25 kvar box type capacitor in lt secondary of transformer , supply and fixing of 5 kvar box type capacitor in apfc panel , supply and fixing of 7.5 kvar box type capacitor in apfc panel , calibration of apfc meter automatic power factor correction , ht gloves with isi mark , flp type push button station forward and reverse , flp type push button station on or off , supply of hand driven megger 500 volt insulation tester waco make metal case , supply of digital multi meter 15b plus model fluke make , earth tester digital waco make , supply of flameproof led 90 w with enclosure

CTN :41290731 Due date: 11 Aug, 202511 Aug, 2025 NA
Tender For providing of calibration services - electrical; voltage, current, power (ac/dc), frequency, power factor, phase angle, dose rate meter; nabl labs; lab

Central Government/Public Sector

CTN :41295449 Due date: 12 Aug, 202512 Aug, 2025 NA
Tender For supply of micro ohm meter similar to motwane model no : lr2045 s employing 4 - wire (4w) measure ments for low resistance measurements from 1micro ohm to 2000 ohms having six ranges with test curren t from 100 microampere to 1 ampere, accuracy: +/-0.05%+/-5, with standard accessories viz.(1) test leads with gpkelvin clip (3 mtrs), (2) main cord (3) user manual, and (4) calibration certificate with validity of o ne year, make :motwane/fluke/chauvin arnoux/teams . [ warranty period: 30 months after the date of delivery ]

Central Government / Public Sector

CTN :41305008 Due date: 16 Aug, 202516 Aug, 2025 NA
Tender For providing of calibration services - service contract for calibration of mass flow meter at hurl, barauni plant; calibration of mass flow meter; as per nit; as per nit

State Government

CTN :41287244 Due date: 12 Aug, 202512 Aug, 2025 7.84 Lacs
Tender For supplying, installation, testing and commissioning of equipment for setting up of water testing laboratory at je(water supply section) sd-i, apwd, diglipur. chemical parameters testing - supply, installation, testing and commissioning of bench top multiparameter ph meter edge - model - hi2020 of make hanna or equivalent with required buffer/stock solution complete having following specification:, ph electrode : hi11310 ph electrode connectivity : 1 micro usb port for charging and pc connectivity, 1 usb port for storagebattery type/life : built-in rechargeable battery with up to 8 hours of continuous usepower supply : 230vac to 5 vdc adapter environment : 0 to 50 c (32 to 122 f), rh max 95% non-condensingdimensions : 202 x 140 x 12.7mm (8 x 5.5 x 0.5 )weight : 250 g (8.82 oz)( the supplier is also required to supply 01 no. additional hi11310 ph eclectrode of same make and specification & additional 500 ml bottle of standard calibration solution of ph 4.01, 7.01 and 10.01 each , 500 ml bottle of electrode storage solution and 500 ml bottle of general pourpose cleaning solution of make hanna along with the above specified instrument set), supply, installation, testing and commissioning of bench top multiparameter ec/tds/salinity meter edge - model - hi2030 of make hanna or equivalent with required buffer/stock solution complete having following specification:, ec/tds probe : hi 763100 ec/temperature probeconnectivity : 1 micro usb port for charging and pc connectivity, 1 usb port for storageglp : yesbattery type/life : built-in rechargeable battery with up to 8 hours of continuous usepower supply : 230vac to 5 vdc adapter environment : 0 to 50 c (32 to 122 f), rh max 95% non-condensingdimensions : 202 x 140 x 12.7mm (8 x 5.5 x 0.5 )weight : 250 g (8.82 oz)( the supplier is also required to supply 01 no. additional hi763100 ec/temperature probe of same make and specification & additional 500 ml bottle of standard conductivity solution of 1413 s/cm , 5000 s/cm and 12880 s/cm each of make hanna along with the above specified instrument set), supply, installation, testing and commissioning of epa compliant benchtop turbidity and chlorine meter - model - hi83414 of make hanna or equivalent with required calibration cuvettes complete having following specification:, turbidity range : non-ratio mode: 0.00 to 9.99; 10.0 to 40.0 ntu; 0.0 to 99.9; 100 to 268 nephelos; 0.00 to 9.80 ebc turbidity range : ratio mode: 0.00 to 9.99; 10.0 to 99.9; 100 to 4000 ntu; 0.0 to 99.9; 100 to 26800 nephelos; 0.00 to 9.99; 10.0 to 99.9; 100 to 980 ebc.free chlorine range : 0.00 to 5.00 mg/ltotal chlorine range : 0.00 to 5.00 mg/lconnectivity : usbglp : last calibration data, calibration infoauto end : do onlybod/our/sour : yes (inside/outside limits)display : 40 x 70 mm graphic lcd (64 x 128 pixels) with backlightpower supply : 115/130 vac; 50/60 hzenvironment : 0 to 50 c (32 to 122 f), rh max 95% non-condensingdimensions : 230 x 200 x 145 mm (9.0 x 7.9 x 5.7 )weight : 2.5 kg (88 oz.)( the supplier is also required to supply 04 nos. additional calibration glass cuvettes for turbidity and chlorine, 230 ml cuvettes cleaning solution, silicone oil each of make hanna along with the above specified instrument set), supply, installation, testing and commissioning of water & wastewater multiparameter (with cod) photometer and ph meter - model - hi83399 of make hanna or equivalent with required calibration cuvettes complete having following specification:, input channels : 1 ph electrode input and 5 photometer wavelengthsphotometer/colorimeter light source : 5 leds with 420 nm, 466 nm, 525 nm, 575 nm, and 610 nm narrow band interference filtersphotometer/colorimeter light detector : silicon photo detectornumber of methods : 128 max.connectivity : usb-a host for flash drive; micro-usb-b for power and computer connectivityglp : calibration data for connected ph electrodedisplay :128 x 64 pixel lcd with backlightpower supply : 5 vdc usb 2.0 power adapter

corporations/Associations/Others

CTN :41287651 Due date: 11 Aug, 202511 Aug, 2025 1.08 Lacs
Tender For calibration and servicing of lab instruments and equipments of water quality monitoring unit at amrit bhawan, vinay marg - service and calibration of colony counter digital (pooja scientific) including furnishing of calibration certificate complete to the entire satisfaction of engineer-in-charge., service and calibration of oven universal with temp. control including furnishing of calibration certificate complete to the entire satisfaction of engineer-in-charge., service and calibration of multiparameter digital ph.condectivity /ldo with all prob for ph/cond./tds/ldo including furnishing of calibration certificate complete to the entire satisfaction of engineer-in-charge., service and calibration of bod incubator 0-50 degree celsius including furnishing of calibration certificate complete to the entire satisfaction of engineer-in-charge., service and calibration of pressure gauge 0- 1.5kg/cm of auto clave including furnishing of calibration certificate complete to the entire satisfaction of engineer-in-charge., service and calibration of muffle furnace (pooja scientific) including furnishing of calibration certificate complete to the entire satisfaction of engineer-in-charge., service and calibration of 2100 n turbidity meter(hach) including furnishing of calibration certificate complete to the entire satisfaction of engineer-in-charge., service and calibration of water bath (unitech) including furnishing of calibration certificate complete to the entire satisfaction of engineer-in-charge., service and calibration of micro analytical balance (axis) including furnishing of calibration certificate complete to the entire satisfaction of engineer-in-charge., service and calibration of uv-vis spectrophotometer (wtw) including furnishing of calibration certificate complete to the entire satisfaction of engineer-in-charge.

Co-operative

CTN :41311266 Due date: 11 Aug, 202511 Aug, 2025 NA
Tender For a.m.c. of digital rpm meter servicing, repairing and calibration, instruments repair and spares in season 2025-26

CTN :41194312 Due date: 08 Aug, 202508 Aug, 2025 17.08 Lacs
Tender For corrigendum : procurement of equipment for nz qc labs d d - titrator auto karl fischer dim 325 180 9 , amc of kf auto titrator first year , amc of kf auto titrator second year , amc of kf auto titrator third year , amc of kf auto titrator fourth year , amc of kf auto titrator fifth year , amc of kf auto titrator sixth year , amc of kf auto titrator seventh year , amc of kf auto titrator eight year , amc of kf auto titrator ninth year , amc of kf auto titrator tenth year , evaporation bath

State Government

CTN :41273531 Due date: 16 Aug, 202516 Aug, 2025 NA
Tender For supply of waterproof portable meter and accessories e e - waterproof portable dissolved oxygen and bod meter , portable multi-parameter tester , digital thermometer , student plankton net , digital thermo hygrometer , magnetic stirrer with hot plate , alkalinity measurement kit , aluminum measurement kit , ammonia mr measurement kit , bromine measurement kit , chlorine, free measurement kit , chlorine, total measurement kit , chromium vi lr measurement kit , copper lr measurement kit , cyanuric acid measurement kit , hydrazine measurement kit , iodine measurement kit , ozone measurement kit , silica measurement kit , dissolved oxygen electrolyte solution , zero oxygen solution set , 100 percent naci calibration solution , 111800 ms per cm conductivity standard , calcium chloride anhydrous , labolene
 Loading, Please wait...

Connect us via What's Up