Web Analytics Made Easy - StatCounter

Toilet Sensor Repair Tenders

Get complete information related to latest Toilet Sensor Repair Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Toilet Sensor Repair Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Toilet Sensor Repair Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

Central Government And Public Sector

CTN :41056783 Due date: 21 Jul, 202521 Jul, 2025 NA
Tender For ac drive 37kw/50hp. supply & testing of ac drive specification; 1.ac drive required to drive squirrel cage im:37kw/50hp, 3ph, 415vac, 50hz, 4pole/6pole, s4 duty for crane hoist/ lt, appli cation. 2.ac drive mains supply:3ph, 380-400vac 50hz. 3.ac drive o/p rating, high overload capacity :37kw 4.drive o/p rating, normal ol capacity:45kw 5.panel mounting type, protection:ip-20 6.drive t o work without encoder feedback system with suitable current feedback system for speed control with required braking chopper, rfi & emc filter. 7.drive with inbuilt protection system: drive overload, exc essive load, ground fault, heatsink over temp., motor over load, over speed limit, over voltage, under voltage, short circuit etc. 8.ac drive to work from digital inputs in, up/down or forward/reverse di rection & in jog, start, stop, speed-1, speed-2 & speed-3 modes. 9.drive with standard minimum; 6 digital i/ps, 2 digital o/ps, 2 analog i/ps, 1 analog o/p & 2 relay o/ps. 10.drive shall have hmi with t ouchpad key mounted to display various operating parameters in english. hmi with editing drive para meters & self-monitoring watch dog facility to display fault & alarm indications. 11.drive software pro gram for crane duty be supplied in soft copy. 12. cable to communicate between laptop & ac drive b e supplied & operating manual in hard copy. 13.joint inspection at rwf, rwf will make necessary cab le connections to the rated capacity im & ac drive. supplier has to test ac drive for rated capacity ind uction motor on the crane/equipment & tuned parameters in soft copy. 14.make:danfoss vlt autom ation drive fc-302 series or ab power flex 755 series or siemens s-120 series or abb acs-880-m04 s eries or yaskawa ga-700 series only. 15.while tendering, firm to mention; make,series & complete m odel no & attach technical catalogue of ac drive with tender offer. 16. warranty: 18 months from d.o .supply or 12 months from d.o.commissioning, whichever is earlier. [ warranty period: 18 months a fter the date of delivery ]

CTN :41043744 Due date: 01 Aug, 202501 Aug, 2025 NA
Tender For supply of p1 155sw r z6 5963 007356 electronic module standardized , p1 155sw r z6 6150 005437 cable assy power electrical el inst dri , p1 155sw r z6 1147736 wire harness c 20 laying valve , p1 155sw r z6 6150 006067 cable assy spl purpose electrical cable , p1 155sw r z6 6625 020826 electronic unit speed control , p1 155sw r z6 5145273 side marking light , p1 155sw r z6 5930 028193 arm switch actuator , p1 155sw r z6 5920 006032 arrestor electrical surge panel plate , p1 155sw r z6 3020 013448 gear worm wheel gear wheel , p1 155sw r z6 6110 007585 stabilizer voltage , p1 155sw r z6 1025 000738 case protecting micro switch , p1 155sw r z6 5330 368368 felt mechanical performeed , p1 155sw r z6 5360 032800 spring flat , p1 155sw r z6 1290 001108 drive controller local control system , p1 155sw r z6 1148927 terminal induction loop

State Government

CTN :40985775 Due date: 28 Jul, 202528 Jul, 2025 1.50 Crore
Tender For purchase of gym for strength and conditioning equipments - endurance sectiontreadmill1. machine must be designed for running with heavy duty 4 hp motor.2. should have low start up speed: 0.5 kmph or lesser.3. should have incline increments of 1% or lesser.4. low step height: 7 or lower.5. speed range: 0-20 kmh or more.6. incline: 0-15% or more.7. max user weight: 180 kgs or more.8. belt size : 61 x 22 or more9. should have at least 10 preprogrammed protocols with option for heart rate range control10. led console with feedback for time distance, calories burnt, heartrate, incline, track and more product should have en-957 or astm certification for stationary fitness equipment, curved non- motorized treadmill (self- powered)1. curved non-motorized treadmill should be capable of training the body s all energy systems as a comprehensive system, capable of offering sprinting for aerobic power development2. curved non- motorized treadmill (self powered) should be capable of offering the sports persons to experience a full speed resistance spectrum.3. variable resistance: the curved non- motorized treadmill (self powered) system should have requisite advanced drive technology enabling users to select different levels of reactive resistance, from zero to max. by simply shifting the drive control system, rehab athletes can quickly switch from resistance-free running to an all-out sled push.4. increased metabolic rate: walking with resistance on said curved non-motorized treadmill (self powered) training system should be capable of enhancing energy expenditure significantly compared to walking at the same speed on a traditional treadmill or a non- motorized treadmill without resistance.5. maximum muscle activation: ergonomic design of the curved non-motorized treadmill (self powered) training system should lead to significantly higher activation of the posterior kinetic chain muscles, particularly the glutes and hamstrings, compared to traditional treadmills.6. curved non-motorized treadmill (self powered)- training system should be capable of being operated and controlled exclusively by the force applied / generated by rehab athletes. in order to speed up, provision should be there, where rehab athlete can move to the front of the surface and to slow down, rehab athlete can move to the back of the said treadmill. provision must be there where the training system can be accelerated quickly from a cold start and matches upto the same pace as the rehab athletes intends to attain. the said system should offer an ideal solution for an eco-sustainable facility, by reducing electricity costs and carbon footprint.7. training system should have requisite technology, ergonomic design and advanced engineering solution so that rehab athletes can work hard in a completely safe training environment.the ergonomic design combined with the high- quality components and materials should be of solid, compact product with a versatile nature that endures well to suit high intensity prolong training sessions to ensure maximum durability and reliability.8. provision for proper posture control:the ergonomic design of training system promotes the correct alignment of the ankles, knees, hips and back, so that user can maintain natural posture at all- times and avoid joint and knee stress, regardless of their height and weight. system should offer the provision of simulating the experience of walking/running uphill while preserving the correct biomechanics.9. accessory kit: the training system must be provided with accessory kit which allows for a variety of pulling and pushing exercises through handles or a waist belt.10. technical specifications:a) dimensions range (lxwxh)*:190-200cmx86- 95cmx150-160cmb) console type: a minimum of 6-7 lcd display with back lightc) power supply: lps 5v wall supplyd) power requirement: 200 - 240 v (should comply with standard indian electrical system)e) resistance control: should have magnetic resistance with a minimum of 8-10 l

CTN :40888702 Due date: 21 Jul, 202521 Jul, 2025 NA
Tender For soft starter for 3- phase induction motor (90 kw) 3-phase, 415vac, 50 hz ac for nf combust ion & id fan motor with following specification:-(i) adjustments:initial start voltage,start ramp time, soft st op ramptime, motor flccurrent ramp,current limit, motor trip class. soft stoptime, excess starttime, pha se sequence protection, auxiliary relay protection. (ii) indications: no control power, starter ready, starter tripped, motor not running, motor running at full speed, motor starting/ stopping. (iii) alarms: power circuit , supply frequency, communication problem, excess start time, motor overload, motor thermistor, phase i mbalance, phase sequence.(iv) digital input start, stop, motor thermistor probe. (v) digital output: main c ontactor relay, programmable relay. (vi) local reset. (vii) control power supply: 110 vac (viii)power supp ly 415 vac, with installation, testing, commissioning, proper fitment & interfacing with existing system.m ake-l & t, crompton greaves, hitachi, abb, siemens, schneider electric, nord drive system, allen bradley or similar. [ warranty period: 12 months after the date of delivery ]
 Loading, Please wait...

Connect us via What's Up