Tender For supply of op track stores - complete supply of mild steel metal double beam crash barrier for op track as per ts , convex mirror 60 cm dia alongwith 75mm dia ms pole up to 3 mtr high with complete fittings as per ts , dwc pipe confirming of is 16205 as per tech sanction , complete plant spares for op track as per tech sanction , misc stores as per tech sanction
Tender For supply and application of insulation materials on pipe, equipment for part a and part b as per standard specification by providing all required materials in connection with the composite work for setting upof hpg-2, butene-1 and psa units atlepetkata - legends / notes for insulation workstypes of insulation : ih = insulation for heat conservation it = insulation for steam traced lines is = insulation for personal safety ic = cold insulation for anti-condensation ie = insulation for electrically traced lines ij = insulation for jacketed lines ik = insulation for dual insulated lines basic line surface materials : cs = carbon steel (including lt carbon steel), as = alloy steel, ss = stainless steelnotes :1. for insulation type it,tracer size and tracer numbers shall be as per specification.2. insulation thickness for ic where insulation material is poly urethane foam (puf) / poly isocyanurate (pic) + cellular glass includes outer layer of 50mm of cellular glass and inner layer of balance thickness of puf/pic.3. insulation for ie consists of inner layer of rockwool and outer layer of puf / pic. the thicknesses have been specified as thk(i) and thk(o) for inner and outer layers respectively., part a, hot insulation (units)providing thermal insulation including supply of all insulating and ancillary materials, vapour barrier, weather protective coverings, consumables and other necessary materials , testing of materials as required, including transportation of materials to work site, duly inspected by 3rd party inspector(llyods/bv/dnv or any other client approved party) at manufacturers shop & sample check/inspection at site by eil construction inspector, applying insulation on surfaces as specified including all preparatory work there on, binding, tying, lacing, stitching and/or otherwise securing , finishing with sheet cladding as per spec. , providing bolts, rivets, and self tapping screws wherever specified , providing inspection windows, end seals for flanges etc., colour coding and identification. providing steel scaffolding, all tools , tackles , equipments etc. , labour, supervision and completing the work in all respect, at all heights as per drawings , specifications and instructions of engineer-in-charge. (refer legend for applicable eil specification), insulation type : ih ; surface material : cs & as ; operating temp. range : upto 125 (deg c) ; insulation material : rockwool, pipes, nb 00.75 inches; thickness 25 mm, nb 01.00 inches; thickness 25 mm, nb 01.50 inches; thickness 25 mm, nb 02.00 inches; thickness 25 mm, nb 03.00 inches; thickness 25 mm, nb 04.00 inches; thickness 25 mm, nb 06.00 inches; thickness 25 mm, blind flange assemblies, nb 00.75 inches; thickness 25 mm, nb 02.00 inches; thickness 25 mm, valve assemblies, nb 00.75 inches; thickness 25 mm, insulation type : ih ; surface material : cs & as ; operating temp. range : 126 (deg c) to 350 (deg c) ; insulation material : rockwool, pipes, nb 00.50 inches; thickness 25 mm, nb 00.50 inches; thickness 40 mm, nb 00.75 inches; thickness 25 mm, nb 00.75 inches; thickness 40 mm, nb 00.75 inches; thickness 50 mm, nb 01.00 inches; thickness 25 mm, nb 01.00 inches; thickness 40 mm, nb 01.00 inches; thickness 50 mm, nb 01.50 inches; thickness 25 mm, nb 01.50 inches; thickness 40 mm, nb 01.50 inches; thickness 50 mm, nb 02.00 inches; thickness 25 mm, nb 02.00 inches; thickness 40 mm, nb 02.00 inches; thickness 50 mm, nb 02.00 inches; thickness 65 mm, nb 03.00 inches; thickness 25 mm, nb 03.00 inches; thickness 40 mm, nb 03.00 inches; thickness 50 mm, nb 03.00 inches; thickness 65 mm, nb 04.00 inches; thickness 25 mm, nb 04.00 inches; thickness 40 mm, nb 04.00 inches; thickness 65 mm, nb 06.00 inches; thickness 40 mm, nb 06.00 inches; thickness 65 mm, flange assemblies, nb 01.50 inches; thickness 25 mm, nb 01.50 inches; thickness 50 mm, nb 02.00 inches; thickness 25 mm, nb 02.00 inches; thickness 40 mm, nb 02.00 inches; thickness 50 mm, nb 03.00 inches; thickn
Tender For electrical maintenace jobs at mughalsarai ird - routine electrical maintenance of depot , transformer oil testing , installation of acb spares , srvc f inspection and pm of acbs , servicing overhauling and testing f vcb , thermography testing of panel , sply instln lightning arrestor , earthing wire cu 6mm2 , sply and fixg of fuse element rating 11k , earthing clamp , calibration of meter , testing calibration of relay , repair of boom barrier , repair and maint of water pump , testing and servicing pv vent 3in , maint and insp tsvtest and re inst half yrly , sply of 33 kv rubber hand gloves isi app , 11kv rubber hand gloves , silica gel , distilled water battery litres , testing of transformer tan delta , rewinding of motor pump overhauling , electrical insulation mat 2 point 5 mm thick , pvc tape steel grip , crc spray cap 200ml , sply and instln of contactor rat 32a , elcb 30 ma 63 a legrand rating 415v 0 point 0 , elcb 32a 30ma dp w 2nosauxtrpcntct , mcb 415vac 32a 10ka 3p c iec60898 1 , mcb 415vac 63a 10ka 3p c iec60898 1 , hrc fuses for diodes 50a , sply and instln of contactor rat 70a , trip shunt coil acb 110vdc land t , braided wire cu 6mm2 , braided wire strip cu 1in , itc of lugs for 16 sqmm cu , lug ring cu 25mm2 , lamp led indctng 60w rd ylw bl hghmst cg , sup led driver 60w , racking mechanism up acb l and t upower , closing coil shnt trp 110vdc acb 800a , extl safety auditdepot terminal plant , sup and fix of crocodile cliphvydty f earth , contactor dc 110vdc 100a 3p btry chrgr , earthing strip size 50x60x6mm , testing of ht cable meggering and continuity , testing of lt cable meggering and continuity , partial disch testing of cable ht and lt , sply and instln of 2way flp jbtestg and comm , vlf testing of cable , earthing funnel gi , ss nut bolt 1 inch , sup and lay wbmstone aggregate 90 45mm , testing ir and motor tmnl conn yearly , preparation drawingloop diagram layout , autocad drawing retracinglayout conversi
Tender For name of work : guntakal division: ru-kdp section (sr.den/south/gtl): provision of safety fencing along the track for speed 130kmph and above using nhai anti-crash barrier / w-beam steel fencing for 134.704km fencing length (phase-ii) under aden/rjp sub division. (two packet).
Tender For name of work : guntakal division: gdr-tpty & ru - gy section (sr.den/south/gtl): provision of safety fencing along the track for speed 130kmph and above using nhai anti-crash barrier / w-beam steel fencing for 77.23 km fencing length (phase-ii) under aden/ru sub-division
Tender For guntakal division: ru - kdp section (sr.den/south/gtl): provision of safety fencing along the track for speed 130kmph and above using nhai anti-crash barrier / w-beam steel fencing for 95.99 km fencing length (phase-ii) under aden/hx sub-division (two packet).
Tender For supply of 50 pair 0.5mm dia polythene sheathed jelly filled underground telephone cable wit h poly aluminium moisture barrier annealed copper conductor double steel tape armoured with polythene j acketed as per rdso specn. no.irs.tc.41/97 , amdt.3 or latest length should be 500 mtrs. drum. [ warran ty period: 30 months after the date of delivery ]
Tender For bid to ras bid to ras corrigendum : supply of boom barrier brushless dc motor with opening time 0.6 to 2.5 sec , round arm 5 mtr length , remote with receiver 02 remote with each boom barrier , single channel loop detector , push button , 4 door controller , 2kva online ups with inbuilt battery , 12u outdoor steel rack , 2 core power cable 2.5 sq mm , traffic light , ofc cable 6 core , media converter , 6u rack fully loaded , hdpe duct pipe 25 mm , server computer system with software , digging and laying of cable , installation commissioning and testing charges for complete job