Get complete information related to latest Traffic Sign Repair Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Traffic Sign Repair Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Traffic Sign Repair Tenders.
Tender For design, engineering, supply, installation, testing and commissioning of an alert, inform and direct system at six (6) sites - control & monitoring :- the control room shall be set up in the already constructed/available room at the pandoh dam area. this system should include a minimum 43-inch (hd) screen with an adjustable stand, capable of monitoring the operation of the siren station. it should display all feedback, including the status of being on or off, battery health, any faults etc. in the installed equipment. additionally, this system must have the capability to communicate directly with the control room to provide alerts and information in real time., for supply ,testing, designing, erection and commissioning of local station for alert, information and direct system comprising of the following hardware/software: panel/housing with power supply module. the controller, linked with all the control units through a communication and integration unit, displays the system via screens. the sirens should also be remote controlled. the control of the sirens should be according to the commands received from the remote central control station through a two-way gsm/gprs/3g/4g/lte and provision of vsat. security feature including intrusion alarm auxiliary/status control board for contact closure activation and status. the siren system should withstand outdoor environment condition & the siren assembly should be rust proof to withstand harsh and saline environmental condition. single point clicks activation & polling. status monitoring. complete configuration & reprogramming for control site. minimum 15,000 message alert notification through gsm/3g/4g/5g/lte/vsat to bbmb officials/ administrators and local residents according to requirement. programmable hot keys. communication over tcp/ip secure access with password. ethernet cable length :- the bidder shall be responsible for the supply and erection of all cabling required for the complete system, ensuring that the cables are of reputable make only and conform to the prescribed standards as per site requirements. rtu & software :- the r.t.u. and software as per the manufacturer`s design / program, the software should be suitable for controls up to 100+ sirens, the system can be expanded to accommodate changing needs. the software should be app and web based. communication between control centre and sirens. :- gsm/3g/4g/5g/lte network/vsat. pre-recorded voice messages :- live and pre-recorded voice messages in minimum 3 local languages i.e. (hindi, punjabi and english) strobe light :- high intensity led strobe light, color red, amber, green, 60-120 flashes per minute (adjustable), led life > 50000 hrs., pole/top mountable with 360 visibility preferably ip 66. alert tones & voice:- minimum 5 standard alert tones. support transmission of stored voice in siren/voice controller through wave file in memory card, remote activation. remote activation of alert tones and pre-recorded voices the voice messages will be customized, optimized for good quality for the intended location, language preferably in punjabi, hindi & english. warranty period:- 3 years., input power source :- the quantity of solar photovoltaic panels and batteries shall be adequate to meet the systems operational requirements. only reputed manufacturers such as tata solar, vikram, waaree, reil, or equivalent brands shall be supplied. the solar panel input source shall be integrated with the required number of batteries to run the installed system continuously for a minimum duration of three (3) days under idle running conditions. this includes six (6) operational cycles per day, with each cycle lasting a minimum of twenty (20) minutes. a secondary provision for electrical input supply shall be provided to enable system operation in the event of solar panel failure or insufficiency beyond the designed power supply capacity., siren type :- bi-directional electronic siren pre-programmed audio amp
Tender For tender for supply of infra for digital information analysis d d - macintosh operating system-based computer , widescreen display device , mechanical keyboard , multipurpose mouse with customizable buttons , external graphics card unit for ai related tasks , monitor mounting unit
Tender For supply of laser mono printer , ups 1 kva , desktop computer , led information display system , info system controller , cat 6 cable for outdoor (q2)
Tender For corrigendum : supply of dome camera , bullet camera , ptz camera , video management system , enterprise vms license , 55 inch display , hard disk 16 tb , workstation with display , core router with 16 1by10 gig ports , layer 3 24 port sfp distribution switch and 25 40 gig with rps accessories , 24 port poe switch 10 100 1000 mbps with sfp sfp28 accessories , 48 port poe switch 10 100 1000 mbps with sfp sfp28 accessories , 12 port poe switch 10 100 1000 mbps with sfp sfp28 accessories , next generation firewall , vms server , recording server , network management software , network management software, incl. server for nms , 30kva 3 ph ups , 5 years oem support warranty cost , resident engineer working minimum 40 hours week for 5 years , ms pole 5 mtrs , cat 6a u utp copper cable , cat 6a 24port unloaded patch panel , cat 6a information outlet for rack side , cat 6a information outlet for field side , cat 6a singlex face plate with backbox , cat 6a duplex face plat with backbox , cat 6a patch cord 2 meter , 06 core fiber cable om4 mm , 12 core liu with loaded all accessories , 24 core liu with loaded all accessories , lc lc fiber patch cord type 3mtr , cable manager , 25mm pvc conduit , 100mm gi raceway , 200mm gi raceway , 300mm gi raceway , 1u rack , 12u rack 600x600 mm , 42u rack 1000x1000 mm