Tender For tender for supply of make- ird mechanalysis limited , ird544m - vibration sensor , inductive velocity , top exit , mil 2-pin connector , 42.52mv/mm/s , 10 hz - 1 khz sku - m97120 , make- ird mechanalysis limited , stud for vibration sensor item no 1 , mounting/grub screws , 1/4 inch-28unf male , m6 x 1 male sku - stud-m6 provides connection between vibration sensor and mounting pad , m/s ird mechanalysis limited , vibration sensor mounting pad mild steel blackodized for ird544m (60x60x16 mm) with m6 thread for item no 1 tapped sku - ms-pad-ird544m , make- m/s ird mechanalysis limited , vibration sensor cable assembly for item no 1 , signal cable teflon 3.5mm dia , ss conduit 5mm id , 15 meter length straight , 2 pin ms , shielded , spade lugs at free end sku - m601015spade lugs at free end carry following colour code- red core- signal live , black core- signal ground , green core- signal shield , make- ird mechanalysis limited , eddy current pickup set comprising of probe , driver and connecting cable for 9 meter system. constituents. , make- m/s ird mechanalysis limited ird8800 rack , 8 position , 5u sku - m88008 this is the bin and will accomodate ird8800 cards , make- ird mechanalysis limited ird8800 (8800) , m88250 (88250) casing vibration module , 2ch velometer input (mv /mm/sec) and 1ch key phasor input , api standard 670 compliant sku - m88250-dc ird8800 series module m88250 can work with all types of velocity output vibration sensors that provide mv/mm/sec output - like ird531 (4 mv/mm/sec) and ird544m (42.52 mv/mm /sec) , make- m/s ird mechanalysis limited , ird8800 (8800) , m88900 (88900) - speed module , 2ch eddy current pickup input , api standard 670 compliant , input- 24 v dc , sku - m88900-dc , input- accelerometer and/or velometer , outputs-4-20 ma dc output proportional to full scale vibration rs-485 modbus rtu/tcp-ip output buffered output alarm relay contacts trip relay contacts full scale , alarm , trip , units , sensitivity and other parameters are programmable and password protected , make- ird mechanalysis limited , ird8800 (8800) , m88600 (88600) - eccentricity module , 2ch eddy current pickup input , api standard 670 compliant , input- 24 v dc , sku - m88600-dc input- accelerometer and/or velometer , outputs-4-20 ma dc output proportional to full scale vibration rs-485 modbus rtu/tcpip output buffered output alarm relay contacts trip relay contacts full scale , alarm , trip , units , sensitivity and other parameters are programmable and password protected , make- ird mechanalysis limited , 35 mm din rail mount industrial grade power supply , 480 w , product- rps480 , 24 v dc output , dimension- 60 x 154 x 158.55 mm (w x h x d) , weight- 1050 gms , sku - rps480-24-ce supports 90 - 264 vac / 127 - 370 vdc power factor more than 0.95 full load over entire input range protection against short circuit , overload , overvoltage & over temperature cooling by free air convection ul 508 approved (e522848) efficiencies up to 93 % dc ok relay contact , make- ird mechanalysis limited , cabinet 1500 x 600 x 600 in mm , ip32 sku - cabinet-1500-600-600-ip32 , installation commissioning and calibration check of all supply sensor with unit at site
Tender For supply and installation of networking items - networking items, l2 managed switch (l2 managed switch 24 x 10/100/1000 base-t poe and 4 x 10g sfp+ ports l2 managed switch with poe budget (370w), indoor wireless access point (indoor wireless access point indoor access point, 1 x rj45 console port, 1 x 10/100/1000 ethernet, (poe) lan, 2 x dual-band internal antennas, antenna gain 3.2 dbi (2.4 ghz), 4.3 dbi (5 ghz), maximum output power 23 dbm (2.4 ghz), 26 dbm (5 ghz), data signal rate up to 1800 mbps, outdoor wireless access point (wireless access point: wi-fi 6 (802.11ax) 2975mbps access points for outdoor environments, dual radio, 5 ghz and 2.4 ghz 11ax 2x2+2x2 mimo, 2402mbps(5ghz) + 574mbps(2.4ghz), wi-fi controller (wi-fi controller for indoor and outdoor wireless ap), 1g sfp module (1g sfp module connector), installation (installation of switch ap unit controller with required cable, conduit, connector, etc. )
Tender For supply of spares for environmental telemonitoring system c c > f> f-- multi port repeater , single port repeater , intrinsically safe dc to dc power supply module_power supply card , stand by battery 14vdc , intrinsically safe programmable methane base module _base pcb , intrinsically safe programmable co base module _base pcb , intrinsically safe programmable oxygen base module _base pcb , intrinsically safe programmable co display module , intrinsically safe programmable oxygen display module , intrinsically safe programmable methane display module , intrinsically safe programmable sensing module for methane gas _cell head , intrinsically safe programmable sensing module for carbon- , intrinsically safe programmable sensing module for oxygen gas _cell head , temperature sensor , ch4 _methane sensor monitor , o2 _oxygen sensors monitor , co _carbon monoxide sensor , signal converter for vishwa make etms , calibration co-gas mixture with al-canister, 125ppm balance air , calibration ch4-gas mixture with al-canister, 1. 5 percentage _vv balance , calibration o2-gas mixture with al-canister, 18 percentage_vv n2 balance ) /bid number: gem/2025/b/6985607 * /dated: 10-12-2025 & & / bid document1 / 25
Tender For supply of supply of p and f barrier spares for dht ta : : - relay module , current driver , safety switch amplifier , switch amplifier , transmitter power supply , frequency to current converter , signal converter , voltage repeater , repeater , solenoid driver , power rail , power supply
Tender For corrigendum : purchase of equipments - purchase of equipment, 1. configuration design an 8-channel battery analyzer and its accessories 2. power 425 w3. voltage measuring range: 25 mv to 5 v, discharge minimum voltage: 0v or better, accuracy: 0.05% of fs4. current range: 0.5 ma to 6 a, accuracy: 0.05% of fs or better 5. power per channel output power: 30w, stability; +/- 0.1% of fs or better6. time rise time: 1ms (0~full range)7. frequency 10hz8. charge mode of operation: cc, cv, cccv, cp end conditions: voltage, current, relative time, capacity.9. discharge mode of operation: cc, cv, cp, cr, end conditions: voltage, current, test time, capacity, energy.10. pulse mode charge: cp mode, cc mode, discharge: cc mode, cp mode, min pulse width: 500ms, automated switch: automated switch from charge to discharge for each pulse end condition: voltage, relative time11. dcir support for the calculation of the point of the dcir12. cycle cycles: 1 65500 or better, steps: 250 or better, nested function: max three levels of loops13. protective function software, power-down data protection, user-defined safety (upper and lower) tolerance of current, voltage, and delay time14. channel features independent pairs of closed loops for the constant current source and constant-voltage source15. test reports and curves for analysis different types of curves created by software based on user definition. (voltage-time curve, current-time curve, capacity-voltage curve, loops times charge/discharge capacity curve, loops times charge/ discharge efficiency curve, etc.), data reports created by the software. comparison of the performance of the batteries tested in channels, both visually and statistically16. channels independent control17. ac input ac 220v 10% / 50hz 18. voltage and current testing sample 4 wire connecting 19. noise 85db20. data management mysql database21. communication means tcp/ip protocol22. data output excel, txt23. communication interface ethernet port24. number of channels per cabinet 825. accessories: 1. bi-potentiostat: electrochemical workstation or moduletechniques the system should be capable of running the rde / rrde technique simultaneously cyclic voltammetry (cv) with simulation/fitting programs linear sweep voltammetry (lsv) with stripping bulk electrolysis with coulometry (be) differential pulse voltammetry (dpv) with stripping normal pulse voltammetry (npv) with stripping tafel plot (tafel), potentiodynamic deactivation, pitting corrosion, corrosion rate, linear polarization, corrosion current, etc. multi-current steps (istep) amperometric i-t curve (i-t) lifetime testing open circuit potential time (ocpt) chrono amperometry (ca) chrono coulometry (cc) chronopotentiometry with current ramp (cpcr) potentiometric stripping analysis (psa) auxiliary signal measurement channel ir compensation external potential input galvanostatic charge discharge single/multiple cycle -chrono potentiometry (cp) with potential limits, polarity by potential or time, no. of cycles etc. voltage vs current density curves single or multiple potential steps with charge limits, single or multiple current steps, mixed voltage/current control using macro. i-v measurements, i max, pmax, fill factor, etc.impedance ac impedance (imp) 10 hz to 3mhz impedance time (impt) (mott-schottky) impedance potential (impe) impedance simulator with fitting open circuit potential time (ocpt)hardware specification of bi-potentiostat workstation/ module: potentiostat / galvanostat module, 2- or 3- or 4-electrode configuration maximum potential: 10v, maximum current: 250 ma peak or better and 2 amps with +/-25 volts for higher current measurement. compliance voltage: > 13v or better, potentiostat rise time: 300 ns or better galvanostat applied current range: 3na to +/- 100ma or better and upto 2 amps applied current accuracy: 20 pa or better input bias current: 1 pa or better cv and lsv scan rate: 0.000001 to 10,000 v/s. ca and cc pulse width: 0.0001 to 1000 sec imp freque